Cargando…

Optical and electrical recording of neural activity evoked by graded contrast visual stimulus

BACKGROUND: Brain activity has been investigated by several methods with different principles, notably optical ones. Each method may offer information on distinct physiological or pathological aspects of brain function. The ideal instrument to measure brain activity should include complementary tech...

Descripción completa

Detalles Bibliográficos
Autores principales: Rovati, Luigi, Salvatori, Giorgia, Bulf, Luca, Fonda, Sergio
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1934360/
https://www.ncbi.nlm.nih.gov/pubmed/17610733
http://dx.doi.org/10.1186/1475-925X-6-28
_version_ 1782134342808502272
author Rovati, Luigi
Salvatori, Giorgia
Bulf, Luca
Fonda, Sergio
author_facet Rovati, Luigi
Salvatori, Giorgia
Bulf, Luca
Fonda, Sergio
author_sort Rovati, Luigi
collection PubMed
description BACKGROUND: Brain activity has been investigated by several methods with different principles, notably optical ones. Each method may offer information on distinct physiological or pathological aspects of brain function. The ideal instrument to measure brain activity should include complementary techniques and integrate the resultant information. As a "low cost" approach towards this objective, we combined the well-grounded electroencephalography technique with the newer near infrared spectroscopy methods to investigate human visual function. METHODS: The article describes an embedded instrumentation combining a continuous-wave near-infrared spectroscopy system and an electroencephalography system to simultaneously monitor functional hemodynamics and electrical activity. Near infrared spectroscopy (NIRS) signal depends on the light absorption spectra of haemoglobin and measures the blood volume and blood oxygenation regulation supporting the neural activity. The NIRS and visual evoked potential (VEP) are concurrently acquired during steady state visual stimulation, at 8 Hz, with a b/w "windmill" pattern, in nine human subjects. The pattern contrast is varied (1%, 10%, 100%) according to a stimulation protocol. RESULTS: In this study, we present the measuring system; the results consist in concurrent recordings of hemodynamic changes and evoked potential responses emerging from different contrast levels of a patterned stimulus. The concentration of [HbO2] increases and [HHb] decreases after the onset of the stimulus. Their variation shows a clear relationship with the contrast value: large contrast produce huge difference in concentration, while low contrast provokes small concentration difference. This behaviour is similar to the already known relationship between VEP response amplitude and contrast. CONCLUSION: The simultaneous recording and analysis of NIRS and VEP signals in humans during visual stimulation with a b/w pattern at variable contrast, demonstrates a strong linear correlation between hemodynamic changes and evoked potential amplitude. Furthermore both responses present a logarithmic profile with stimulus contrast.
format Text
id pubmed-1934360
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-19343602007-07-28 Optical and electrical recording of neural activity evoked by graded contrast visual stimulus Rovati, Luigi Salvatori, Giorgia Bulf, Luca Fonda, Sergio Biomed Eng Online Research BACKGROUND: Brain activity has been investigated by several methods with different principles, notably optical ones. Each method may offer information on distinct physiological or pathological aspects of brain function. The ideal instrument to measure brain activity should include complementary techniques and integrate the resultant information. As a "low cost" approach towards this objective, we combined the well-grounded electroencephalography technique with the newer near infrared spectroscopy methods to investigate human visual function. METHODS: The article describes an embedded instrumentation combining a continuous-wave near-infrared spectroscopy system and an electroencephalography system to simultaneously monitor functional hemodynamics and electrical activity. Near infrared spectroscopy (NIRS) signal depends on the light absorption spectra of haemoglobin and measures the blood volume and blood oxygenation regulation supporting the neural activity. The NIRS and visual evoked potential (VEP) are concurrently acquired during steady state visual stimulation, at 8 Hz, with a b/w "windmill" pattern, in nine human subjects. The pattern contrast is varied (1%, 10%, 100%) according to a stimulation protocol. RESULTS: In this study, we present the measuring system; the results consist in concurrent recordings of hemodynamic changes and evoked potential responses emerging from different contrast levels of a patterned stimulus. The concentration of [HbO2] increases and [HHb] decreases after the onset of the stimulus. Their variation shows a clear relationship with the contrast value: large contrast produce huge difference in concentration, while low contrast provokes small concentration difference. This behaviour is similar to the already known relationship between VEP response amplitude and contrast. CONCLUSION: The simultaneous recording and analysis of NIRS and VEP signals in humans during visual stimulation with a b/w pattern at variable contrast, demonstrates a strong linear correlation between hemodynamic changes and evoked potential amplitude. Furthermore both responses present a logarithmic profile with stimulus contrast. BioMed Central 2007-07-04 /pmc/articles/PMC1934360/ /pubmed/17610733 http://dx.doi.org/10.1186/1475-925X-6-28 Text en Copyright © 2007 Rovati et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Rovati, Luigi
Salvatori, Giorgia
Bulf, Luca
Fonda, Sergio
Optical and electrical recording of neural activity evoked by graded contrast visual stimulus
title Optical and electrical recording of neural activity evoked by graded contrast visual stimulus
title_full Optical and electrical recording of neural activity evoked by graded contrast visual stimulus
title_fullStr Optical and electrical recording of neural activity evoked by graded contrast visual stimulus
title_full_unstemmed Optical and electrical recording of neural activity evoked by graded contrast visual stimulus
title_short Optical and electrical recording of neural activity evoked by graded contrast visual stimulus
title_sort optical and electrical recording of neural activity evoked by graded contrast visual stimulus
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1934360/
https://www.ncbi.nlm.nih.gov/pubmed/17610733
http://dx.doi.org/10.1186/1475-925X-6-28
work_keys_str_mv AT rovatiluigi opticalandelectricalrecordingofneuralactivityevokedbygradedcontrastvisualstimulus
AT salvatorigiorgia opticalandelectricalrecordingofneuralactivityevokedbygradedcontrastvisualstimulus
AT bulfluca opticalandelectricalrecordingofneuralactivityevokedbygradedcontrastvisualstimulus
AT fondasergio opticalandelectricalrecordingofneuralactivityevokedbygradedcontrastvisualstimulus