Cargando…
Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion.
Angiotensin II (AT-II) has been used to target regionally-administered cytotoxic microspheres in patients with intrahepatic tumours. The optimisation of vasoconstrictor targeting requires a knowledge of the blood flow changes induced by agents such as AT-II. We therefore assessed duplex/colour Doppl...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
1993
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1968510/ https://www.ncbi.nlm.nih.gov/pubmed/8512823 |
_version_ | 1782134755861463040 |
---|---|
author | Leen, E. Angerson, W. J. Warren, H. W. Goldberg, J. A. Sutherland, G. R. Cooke, T. G. McArdle, C. S. |
author_facet | Leen, E. Angerson, W. J. Warren, H. W. Goldberg, J. A. Sutherland, G. R. Cooke, T. G. McArdle, C. S. |
author_sort | Leen, E. |
collection | PubMed |
description | Angiotensin II (AT-II) has been used to target regionally-administered cytotoxic microspheres in patients with intrahepatic tumours. The optimisation of vasoconstrictor targeting requires a knowledge of the blood flow changes induced by agents such as AT-II. We therefore assessed duplex/colour Doppler sonography (DCDS) as a means of evaluating the effects of AT-II infusion on hepatic arterial blood flow (HABF) and arterial resistance in patients with intrahepatic tumours. HABF was measured continuously in nine patients using DCDS before, during and after an infusion of AT-II (15 micrograms in 3 ml of saline over 90 s) via a hepatic artery catheter. In seven patients with less than 30% hepatic replacement by tumour, the baseline level of HABF was 331 +/- 85 ml min-1 (mean +/- s.d.), and this was reduced by 75-80% within 30 s of the start of AT-II infusion. HABF recovered rapidly from the end of the infusion, and increased by up to 20% above the baseline for approximately 2 min. In two patients with greater than 50% hepatic replacement, HABF showed no reduction but rose continuously from the start of AT-II infusion, increasing by a factor of 2-2.5 after 3-4 min. Arterial resistance showed reciprocal changes in all cases. We conclude that DCDS is effective in assessing the temporal changes in hepatic arterial blood flow caused by AT-II. In order to optimise tumour targeting, the injection of microspheres loaded with cytotoxic drugs should be completed before the end of the AT-II infusion. The targeting advantage of AT-II in patients with a high percentage hepatic replacement by tumour should be re-assessed. |
format | Text |
id | pubmed-1968510 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1993 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-19685102009-09-10 Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion. Leen, E. Angerson, W. J. Warren, H. W. Goldberg, J. A. Sutherland, G. R. Cooke, T. G. McArdle, C. S. Br J Cancer Research Article Angiotensin II (AT-II) has been used to target regionally-administered cytotoxic microspheres in patients with intrahepatic tumours. The optimisation of vasoconstrictor targeting requires a knowledge of the blood flow changes induced by agents such as AT-II. We therefore assessed duplex/colour Doppler sonography (DCDS) as a means of evaluating the effects of AT-II infusion on hepatic arterial blood flow (HABF) and arterial resistance in patients with intrahepatic tumours. HABF was measured continuously in nine patients using DCDS before, during and after an infusion of AT-II (15 micrograms in 3 ml of saline over 90 s) via a hepatic artery catheter. In seven patients with less than 30% hepatic replacement by tumour, the baseline level of HABF was 331 +/- 85 ml min-1 (mean +/- s.d.), and this was reduced by 75-80% within 30 s of the start of AT-II infusion. HABF recovered rapidly from the end of the infusion, and increased by up to 20% above the baseline for approximately 2 min. In two patients with greater than 50% hepatic replacement, HABF showed no reduction but rose continuously from the start of AT-II infusion, increasing by a factor of 2-2.5 after 3-4 min. Arterial resistance showed reciprocal changes in all cases. We conclude that DCDS is effective in assessing the temporal changes in hepatic arterial blood flow caused by AT-II. In order to optimise tumour targeting, the injection of microspheres loaded with cytotoxic drugs should be completed before the end of the AT-II infusion. The targeting advantage of AT-II in patients with a high percentage hepatic replacement by tumour should be re-assessed. Nature Publishing Group 1993-06 /pmc/articles/PMC1968510/ /pubmed/8512823 Text en https://creativecommons.org/licenses/by/4.0/This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit https://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Research Article Leen, E. Angerson, W. J. Warren, H. W. Goldberg, J. A. Sutherland, G. R. Cooke, T. G. McArdle, C. S. Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion. |
title | Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion. |
title_full | Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion. |
title_fullStr | Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion. |
title_full_unstemmed | Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion. |
title_short | Duplex/colour Doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin II infusion. |
title_sort | duplex/colour doppler sonography: measurement of changes in hepatic arterial haemodynamics following intra-arterial angiotensin ii infusion. |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1968510/ https://www.ncbi.nlm.nih.gov/pubmed/8512823 |
work_keys_str_mv | AT leene duplexcolourdopplersonographymeasurementofchangesinhepaticarterialhaemodynamicsfollowingintraarterialangiotensiniiinfusion AT angersonwj duplexcolourdopplersonographymeasurementofchangesinhepaticarterialhaemodynamicsfollowingintraarterialangiotensiniiinfusion AT warrenhw duplexcolourdopplersonographymeasurementofchangesinhepaticarterialhaemodynamicsfollowingintraarterialangiotensiniiinfusion AT goldbergja duplexcolourdopplersonographymeasurementofchangesinhepaticarterialhaemodynamicsfollowingintraarterialangiotensiniiinfusion AT sutherlandgr duplexcolourdopplersonographymeasurementofchangesinhepaticarterialhaemodynamicsfollowingintraarterialangiotensiniiinfusion AT cooketg duplexcolourdopplersonographymeasurementofchangesinhepaticarterialhaemodynamicsfollowingintraarterialangiotensiniiinfusion AT mcardlecs duplexcolourdopplersonographymeasurementofchangesinhepaticarterialhaemodynamicsfollowingintraarterialangiotensiniiinfusion |