Cargando…

Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients.

Glomerular filtration rate (GFR), 131I-Hippuran clearance and estimated creatinine clearance were investigated in 34 patients with cancer. For Hippuran clearance and GFR, analysed with the X-ray contrast (iohexol) and fluorescence technique, the least square linear regression coefficient was 5.01 +/...

Descripción completa

Detalles Bibliográficos
Autores principales: Lindegaard, M. W., Aass, N., Bue, E. S., Theodorsen, L., Fosså, S. D.
Formato: Texto
Lenguaje:English
Publicado: Nature Publishing Group 1991
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1977536/
https://www.ncbi.nlm.nih.gov/pubmed/1892774
_version_ 1782135282480447488
author Lindegaard, M. W.
Aass, N.
Bue, E. S.
Theodorsen, L.
Fosså, S. D.
author_facet Lindegaard, M. W.
Aass, N.
Bue, E. S.
Theodorsen, L.
Fosså, S. D.
author_sort Lindegaard, M. W.
collection PubMed
description Glomerular filtration rate (GFR), 131I-Hippuran clearance and estimated creatinine clearance were investigated in 34 patients with cancer. For Hippuran clearance and GFR, analysed with the X-ray contrast (iohexol) and fluorescence technique, the least square linear regression coefficient was 5.01 +/- 0.41 (r = 0.91). This value concurs with the five to one ratio between GFR and renal plasma flow known from normal physiology and supports that Hippuran clearance is a valid measure of renal function. When the individual values of Hippuran clearance were divided by 5.01, the mean difference between the methods was 0.4 ml min-1 1.73 m-2 with standard deviation 13.4 ml min-1 1.73 m-2. The lower and upper limits of agreement were -26.7 and 25.9 ml min-1 1.73 m-2, respectively. Comparing creatinine clearance estimated from the serum creatinine level with GFR, the limits of agreement were -29.4 and 21.6 ml min-1 1.73 m-2. These agreement limits are in the same range as those which can be calculated from the data from other studies.
format Text
id pubmed-1977536
institution National Center for Biotechnology Information
language English
publishDate 1991
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-19775362009-09-10 Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients. Lindegaard, M. W. Aass, N. Bue, E. S. Theodorsen, L. Fosså, S. D. Br J Cancer Research Article Glomerular filtration rate (GFR), 131I-Hippuran clearance and estimated creatinine clearance were investigated in 34 patients with cancer. For Hippuran clearance and GFR, analysed with the X-ray contrast (iohexol) and fluorescence technique, the least square linear regression coefficient was 5.01 +/- 0.41 (r = 0.91). This value concurs with the five to one ratio between GFR and renal plasma flow known from normal physiology and supports that Hippuran clearance is a valid measure of renal function. When the individual values of Hippuran clearance were divided by 5.01, the mean difference between the methods was 0.4 ml min-1 1.73 m-2 with standard deviation 13.4 ml min-1 1.73 m-2. The lower and upper limits of agreement were -26.7 and 25.9 ml min-1 1.73 m-2, respectively. Comparing creatinine clearance estimated from the serum creatinine level with GFR, the limits of agreement were -29.4 and 21.6 ml min-1 1.73 m-2. These agreement limits are in the same range as those which can be calculated from the data from other studies. Nature Publishing Group 1991-08 /pmc/articles/PMC1977536/ /pubmed/1892774 Text en https://creativecommons.org/licenses/by/4.0/This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit https://creativecommons.org/licenses/by/4.0/.
spellingShingle Research Article
Lindegaard, M. W.
Aass, N.
Bue, E. S.
Theodorsen, L.
Fosså, S. D.
Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients.
title Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients.
title_full Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients.
title_fullStr Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients.
title_full_unstemmed Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients.
title_short Glomerular filtration rate, 131I-hippuran clearance and estimated creatinine clearance in cancer patients.
title_sort glomerular filtration rate, 131i-hippuran clearance and estimated creatinine clearance in cancer patients.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1977536/
https://www.ncbi.nlm.nih.gov/pubmed/1892774
work_keys_str_mv AT lindegaardmw glomerularfiltrationrate131ihippuranclearanceandestimatedcreatinineclearanceincancerpatients
AT aassn glomerularfiltrationrate131ihippuranclearanceandestimatedcreatinineclearanceincancerpatients
AT buees glomerularfiltrationrate131ihippuranclearanceandestimatedcreatinineclearanceincancerpatients
AT theodorsenl glomerularfiltrationrate131ihippuranclearanceandestimatedcreatinineclearanceincancerpatients
AT fossasd glomerularfiltrationrate131ihippuranclearanceandestimatedcreatinineclearanceincancerpatients