ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging

The purpose of the paper is to present and evaluate the performance of a new software-based registration system for patient setup verification, during radiotherapy, using electronic portal images. The estimation of setup errors, using the proposed system, can be accomplished by means of two alternat...

Descripción completa

Detalles Bibliográficos
Autores principales: Asvestas, Pantelis A., Delibasis, Konstantinos K., Mouravliansky, Nikolaos A., Matsopoulos, George K.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1987368/
https://www.ncbi.nlm.nih.gov/pubmed/18521182
http://dx.doi.org/10.1155/2007/61523
_version_ 1782135417844269056
author Asvestas, Pantelis A.
Delibasis, Konstantinos K.
Mouravliansky, Nikolaos A.
Matsopoulos, George K.
author_facet Asvestas, Pantelis A.
Delibasis, Konstantinos K.
Mouravliansky, Nikolaos A.
Matsopoulos, George K.
author_sort Asvestas, Pantelis A.
collection PubMed
description The purpose of the paper is to present and evaluate the performance of a new software-based registration system for patient setup verification, during radiotherapy, using electronic portal images. The estimation of setup errors, using the proposed system, can be accomplished by means of two alternate registration methods. (a) The portal image of the current fraction of the treatment is registered directly with the reference image (digitally reconstructed radiograph (DRR) or simulator image) using a modified manual technique. (b) The portal image of the current fraction of the treatment is registered with the portal image of the first fraction of the treatment (reference portal image) by applying a nearly automated technique based on self-organizing maps, whereas the reference portal has already been registered with a DRR or a simulator image. The proposed system was tested on phantom data and on data from six patients. The root mean square error (RMSE) of the setup estimates was 0.8 ± 0.3 (mean value ± standard deviation) for the phantom data and 0.3 ± 0.3 for the patient data, respectively, by applying the two methodologies. Furthermore, statistical analysis by means of the Wilcoxon nonparametric signed test showed that the results that were obtained by the two methods did not differ significantly (P value > 0.05).
format Text
id pubmed-1987368
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-19873682008-06-02 ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging Asvestas, Pantelis A. Delibasis, Konstantinos K. Mouravliansky, Nikolaos A. Matsopoulos, George K. Int J Biomed Imaging Research Article The purpose of the paper is to present and evaluate the performance of a new software-based registration system for patient setup verification, during radiotherapy, using electronic portal images. The estimation of setup errors, using the proposed system, can be accomplished by means of two alternate registration methods. (a) The portal image of the current fraction of the treatment is registered directly with the reference image (digitally reconstructed radiograph (DRR) or simulator image) using a modified manual technique. (b) The portal image of the current fraction of the treatment is registered with the portal image of the first fraction of the treatment (reference portal image) by applying a nearly automated technique based on self-organizing maps, whereas the reference portal has already been registered with a DRR or a simulator image. The proposed system was tested on phantom data and on data from six patients. The root mean square error (RMSE) of the setup estimates was 0.8 ± 0.3 (mean value ± standard deviation) for the phantom data and 0.3 ± 0.3 for the patient data, respectively, by applying the two methodologies. Furthermore, statistical analysis by means of the Wilcoxon nonparametric signed test showed that the results that were obtained by the two methods did not differ significantly (P value > 0.05). Hindawi Publishing Corporation 2007 2006-11-29 /pmc/articles/PMC1987368/ /pubmed/18521182 http://dx.doi.org/10.1155/2007/61523 Text en Copyright © 2007 Pantelis A. Asvestas et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Asvestas, Pantelis A.
Delibasis, Konstantinos K.
Mouravliansky, Nikolaos A.
Matsopoulos, George K.
ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging
title ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging
title_full ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging
title_fullStr ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging
title_full_unstemmed ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging
title_short ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging
title_sort esterr-pro: a setup verification software system using electronic portal imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1987368/
https://www.ncbi.nlm.nih.gov/pubmed/18521182
http://dx.doi.org/10.1155/2007/61523
work_keys_str_mv AT asvestaspantelisa esterrproasetupverificationsoftwaresystemusingelectronicportalimaging
AT delibasiskonstantinosk esterrproasetupverificationsoftwaresystemusingelectronicportalimaging
AT mouravlianskynikolaosa esterrproasetupverificationsoftwaresystemusingelectronicportalimaging
AT matsopoulosgeorgek esterrproasetupverificationsoftwaresystemusingelectronicportalimaging