Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

BACKGROUND: The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displaceme...

Descripción completa

Detalles Bibliográficos
Autores principales: Macias, Nayeli, Alemán-Mateo, Heliodoro, Esparza-Romero, Julián, Valencia, Mauro E
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2020472/
https://www.ncbi.nlm.nih.gov/pubmed/17697388
http://dx.doi.org/10.1186/1475-2891-6-18
_version_ 1782136602248609792
author Macias, Nayeli
Alemán-Mateo, Heliodoro
Esparza-Romero, Julián
Valencia, Mauro E
author_facet Macias, Nayeli
Alemán-Mateo, Heliodoro
Esparza-Romero, Julián
Valencia, Mauro E
author_sort Macias, Nayeli
collection PubMed
description BACKGROUND: The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP) as standard method to measure body composition in Mexican adult men and women. METHODS: This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg) and height (Ht, cm) were obtained by standard anthropometric techniques. Resistance, R (ohms) and reactance, Xc (ohms) were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM). RESULTS AND DISCUSSION: The final model was: FFM (kg) = 0.7374 * (Ht(2 )/R) + 0.1763 * (BW) - 0.1773 * (Age) + 0.1198 * (Xc) - 2.4658. R(2 )was 0.97; the square root of the mean square error (SRMSE) was 1.99 kg, and the pure error (PE) was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg) and that measured by ADP (48.43 ± 11.3 kg). The new equation did not differ from the line of identity, had a high R(2 )and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg). CONCLUSION: The new bioelectrical impedance equation based on the two-compartment model (2C) was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample.
format Text
id pubmed-2020472
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-20204722007-10-13 Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults Macias, Nayeli Alemán-Mateo, Heliodoro Esparza-Romero, Julián Valencia, Mauro E Nutr J Research BACKGROUND: The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP) as standard method to measure body composition in Mexican adult men and women. METHODS: This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg) and height (Ht, cm) were obtained by standard anthropometric techniques. Resistance, R (ohms) and reactance, Xc (ohms) were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM). RESULTS AND DISCUSSION: The final model was: FFM (kg) = 0.7374 * (Ht(2 )/R) + 0.1763 * (BW) - 0.1773 * (Age) + 0.1198 * (Xc) - 2.4658. R(2 )was 0.97; the square root of the mean square error (SRMSE) was 1.99 kg, and the pure error (PE) was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg) and that measured by ADP (48.43 ± 11.3 kg). The new equation did not differ from the line of identity, had a high R(2 )and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg). CONCLUSION: The new bioelectrical impedance equation based on the two-compartment model (2C) was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample. BioMed Central 2007-08-15 /pmc/articles/PMC2020472/ /pubmed/17697388 http://dx.doi.org/10.1186/1475-2891-6-18 Text en Copyright © 2007 Macias et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Macias, Nayeli
Alemán-Mateo, Heliodoro
Esparza-Romero, Julián
Valencia, Mauro E
Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
title Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
title_full Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
title_fullStr Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
title_full_unstemmed Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
title_short Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
title_sort body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in mexican adults
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2020472/
https://www.ncbi.nlm.nih.gov/pubmed/17697388
http://dx.doi.org/10.1186/1475-2891-6-18
work_keys_str_mv AT maciasnayeli bodyfatmeasurementbybioelectricalimpedanceandairdisplacementplethysmographyacrossvalidationstudytodesignbioelectricalimpedanceequationsinmexicanadults
AT alemanmateoheliodoro bodyfatmeasurementbybioelectricalimpedanceandairdisplacementplethysmographyacrossvalidationstudytodesignbioelectricalimpedanceequationsinmexicanadults
AT esparzaromerojulian bodyfatmeasurementbybioelectricalimpedanceandairdisplacementplethysmographyacrossvalidationstudytodesignbioelectricalimpedanceequationsinmexicanadults
AT valenciamauroe bodyfatmeasurementbybioelectricalimpedanceandairdisplacementplethysmographyacrossvalidationstudytodesignbioelectricalimpedanceequationsinmexicanadults