Cargando…

Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis

BACKGROUND: The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires...

Descripción completa

Detalles Bibliográficos
Autores principales: Carrol, Enitan D, Salway, Fiona, Pepper, Stuart D, Saunders, Emma, Mankhambo, Limangeni A, Ollier, William E, Hart, C Anthony, Day, Phillip
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2031894/
https://www.ncbi.nlm.nih.gov/pubmed/17850649
http://dx.doi.org/10.1186/1471-2172-8-20
_version_ 1782136802773041152
author Carrol, Enitan D
Salway, Fiona
Pepper, Stuart D
Saunders, Emma
Mankhambo, Limangeni A
Ollier, William E
Hart, C Anthony
Day, Phillip
author_facet Carrol, Enitan D
Salway, Fiona
Pepper, Stuart D
Saunders, Emma
Mankhambo, Limangeni A
Ollier, William E
Hart, C Anthony
Day, Phillip
author_sort Carrol, Enitan D
collection PubMed
description BACKGROUND: The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires 2.5 mL blood, which makes routine implementation impractical for paediatric use. The aim of this study was to modify the PAXgene™ Blood RNA System kit protocol for application to small, sick chidren, without compromising RNA integrity, and subsequently to perform quantitative analysis of ICAM and interleukin-6 gene expression. Aliquots of 0.86 mL PAXgene™ reagent were put into microtubes and 0.3 mL whole blood added to maintain the same recommended proportions as in the PAXgene™ evacuated tube system. RNA quality was assessed using the Agilent BioAnalyser 2100 and an in-house TaqMan™ assay which measures GAPDH transcript integrity by determining 3' to 5' ratios. qPCR analysis was performed on an additional panel of 7 housekeeping genes. Three reference genes (HPRT1, YWHAZ and GAPDH) were identified using the GeNORM algorithm, which were subsequently used to normalising target gene expression levels. ICAM-1 and IL-6 gene expression were measured in 87 Malawian children with invasive pneumococcal disease. RESULTS: Total RNA yield was between 1,114 and 2,950 ng and the BioAnalyser 2100 demonstrated discernible 18s and 28s bands. The cycle threshold values obtained for the seven housekeeping genes were between 15 and 30 and showed good consistency. Median relative ICAM and IL-6 gene expression were significantly reduced in non-survivors compared to survivors (ICAM: 3.56 vs 4.41, p = 0.04, and IL-6: 2.16 vs 6.73, p = 0.02). CONCLUSION: We have successfully modified the PAXgene™ blood collection system for use in small children and demonstrated preservation of RNA integrity and successful quantitative real-time PCR analysis.
format Text
id pubmed-2031894
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-20318942007-10-17 Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis Carrol, Enitan D Salway, Fiona Pepper, Stuart D Saunders, Emma Mankhambo, Limangeni A Ollier, William E Hart, C Anthony Day, Phillip BMC Immunol Research Article BACKGROUND: The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires 2.5 mL blood, which makes routine implementation impractical for paediatric use. The aim of this study was to modify the PAXgene™ Blood RNA System kit protocol for application to small, sick chidren, without compromising RNA integrity, and subsequently to perform quantitative analysis of ICAM and interleukin-6 gene expression. Aliquots of 0.86 mL PAXgene™ reagent were put into microtubes and 0.3 mL whole blood added to maintain the same recommended proportions as in the PAXgene™ evacuated tube system. RNA quality was assessed using the Agilent BioAnalyser 2100 and an in-house TaqMan™ assay which measures GAPDH transcript integrity by determining 3' to 5' ratios. qPCR analysis was performed on an additional panel of 7 housekeeping genes. Three reference genes (HPRT1, YWHAZ and GAPDH) were identified using the GeNORM algorithm, which were subsequently used to normalising target gene expression levels. ICAM-1 and IL-6 gene expression were measured in 87 Malawian children with invasive pneumococcal disease. RESULTS: Total RNA yield was between 1,114 and 2,950 ng and the BioAnalyser 2100 demonstrated discernible 18s and 28s bands. The cycle threshold values obtained for the seven housekeeping genes were between 15 and 30 and showed good consistency. Median relative ICAM and IL-6 gene expression were significantly reduced in non-survivors compared to survivors (ICAM: 3.56 vs 4.41, p = 0.04, and IL-6: 2.16 vs 6.73, p = 0.02). CONCLUSION: We have successfully modified the PAXgene™ blood collection system for use in small children and demonstrated preservation of RNA integrity and successful quantitative real-time PCR analysis. BioMed Central 2007-09-12 /pmc/articles/PMC2031894/ /pubmed/17850649 http://dx.doi.org/10.1186/1471-2172-8-20 Text en Copyright © 2007 Carrol et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Carrol, Enitan D
Salway, Fiona
Pepper, Stuart D
Saunders, Emma
Mankhambo, Limangeni A
Ollier, William E
Hart, C Anthony
Day, Phillip
Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis
title Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis
title_full Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis
title_fullStr Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis
title_full_unstemmed Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis
title_short Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis
title_sort successful downstream application of the paxgene blood rna system from small blood samples in paediatric patients for quantitative pcr analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2031894/
https://www.ncbi.nlm.nih.gov/pubmed/17850649
http://dx.doi.org/10.1186/1471-2172-8-20
work_keys_str_mv AT carrolenitand successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis
AT salwayfiona successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis
AT pepperstuartd successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis
AT saundersemma successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis
AT mankhambolimangenia successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis
AT ollierwilliame successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis
AT hartcanthony successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis
AT dayphillip successfuldownstreamapplicationofthepaxgenebloodrnasystemfromsmallbloodsamplesinpaediatricpatientsforquantitativepcranalysis