Cargando…

Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.

Tumours with necrotic regions have an inadequate blood supply and are expected to differ from well-vascularised tumours in response to treatment. The purpose of the present work was to investigate whether proton magnetic resonance imaging (MRI) might be used to detect necrotic regions in tumours. MR...

Descripción completa

Detalles Bibliográficos
Autores principales: Jakobsen, I., Kaalhus, O., Lyng, H., Rofstad, E. K.
Formato: Texto
Lenguaje:English
Publicado: Nature Publishing Group 1995
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2033651/
https://www.ncbi.nlm.nih.gov/pubmed/7880724
_version_ 1782136883796508672
author Jakobsen, I.
Kaalhus, O.
Lyng, H.
Rofstad, E. K.
author_facet Jakobsen, I.
Kaalhus, O.
Lyng, H.
Rofstad, E. K.
author_sort Jakobsen, I.
collection PubMed
description Tumours with necrotic regions have an inadequate blood supply and are expected to differ from well-vascularised tumours in response to treatment. The purpose of the present work was to investigate whether proton magnetic resonance imaging (MRI) might be used to detect necrotic regions in tumours. MR images and histological sections from individual tumours of three different amelanotic human melanoma xenograft lines (BEX-t, HUX-t, SAX-t) were analysed in pairs. MRI was performed at 1.5 T using two spin-echo pulse sequences, one with a repetition time (TR) of 600 ms and echo times (TEs) of 20, 40, 60 and 80 ms and the other with a TR of 2000 ms and TEs of 20, 40, 60 and 80 ms. Spin-lattice relaxation time (T1), spin-spin relaxation time (T2) and proton density (N0) were calculated for each volume element corresponding to a pixel. Synthetic MR images, pure T1, T2 and N0 images and spin-echo images with chosen values for TR and TE were generated from these data. T1, T2 and N0 distributions of tumour subregions, corresponding to necrotic regions and regions of viable tissue as defined by histological criteria, were also generated. T1 and T2 were significantly shorter in the necrotic regions than in the regions of viable tissue in all tumours. These differences were sufficiently large to allow the generation of synthetic spin-echo images showing clear contrast between necrosis and viable tissue. Maximum contrast was achieved with TRs within the range 2800-4000 ms and TEs within the range 160-200 ms. Necrotic tissue could also be distinguished from viable tissue in pure T1 and T2 images. Consequently, the possibility exists that MRI might be used for detection of necrotic regions in tumours and hence for prediction of tumour treatment response. IMAGES:
format Text
id pubmed-2033651
institution National Center for Biotechnology Information
language English
publishDate 1995
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-20336512009-09-10 Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging. Jakobsen, I. Kaalhus, O. Lyng, H. Rofstad, E. K. Br J Cancer Research Article Tumours with necrotic regions have an inadequate blood supply and are expected to differ from well-vascularised tumours in response to treatment. The purpose of the present work was to investigate whether proton magnetic resonance imaging (MRI) might be used to detect necrotic regions in tumours. MR images and histological sections from individual tumours of three different amelanotic human melanoma xenograft lines (BEX-t, HUX-t, SAX-t) were analysed in pairs. MRI was performed at 1.5 T using two spin-echo pulse sequences, one with a repetition time (TR) of 600 ms and echo times (TEs) of 20, 40, 60 and 80 ms and the other with a TR of 2000 ms and TEs of 20, 40, 60 and 80 ms. Spin-lattice relaxation time (T1), spin-spin relaxation time (T2) and proton density (N0) were calculated for each volume element corresponding to a pixel. Synthetic MR images, pure T1, T2 and N0 images and spin-echo images with chosen values for TR and TE were generated from these data. T1, T2 and N0 distributions of tumour subregions, corresponding to necrotic regions and regions of viable tissue as defined by histological criteria, were also generated. T1 and T2 were significantly shorter in the necrotic regions than in the regions of viable tissue in all tumours. These differences were sufficiently large to allow the generation of synthetic spin-echo images showing clear contrast between necrosis and viable tissue. Maximum contrast was achieved with TRs within the range 2800-4000 ms and TEs within the range 160-200 ms. Necrotic tissue could also be distinguished from viable tissue in pure T1 and T2 images. Consequently, the possibility exists that MRI might be used for detection of necrotic regions in tumours and hence for prediction of tumour treatment response. IMAGES: Nature Publishing Group 1995-03 /pmc/articles/PMC2033651/ /pubmed/7880724 Text en https://creativecommons.org/licenses/by/4.0/This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit https://creativecommons.org/licenses/by/4.0/.
spellingShingle Research Article
Jakobsen, I.
Kaalhus, O.
Lyng, H.
Rofstad, E. K.
Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.
title Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.
title_full Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.
title_fullStr Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.
title_full_unstemmed Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.
title_short Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.
title_sort detection of necrosis in human tumour xenografts by proton magnetic resonance imaging.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2033651/
https://www.ncbi.nlm.nih.gov/pubmed/7880724
work_keys_str_mv AT jakobseni detectionofnecrosisinhumantumourxenograftsbyprotonmagneticresonanceimaging
AT kaalhuso detectionofnecrosisinhumantumourxenograftsbyprotonmagneticresonanceimaging
AT lyngh detectionofnecrosisinhumantumourxenograftsbyprotonmagneticresonanceimaging
AT rofstadek detectionofnecrosisinhumantumourxenograftsbyprotonmagneticresonanceimaging