Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies
Morbidity and mortality rates are higher in patients with severe left ventricular (LV) systolic dysfunction and ECG-derived prolonged QRS interval than in those with normal QRS duration. QRS duration is currently used on the grounds that it reflects the presence of ventricular dyssynchrony. However,...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2034540/ https://www.ncbi.nlm.nih.gov/pubmed/17822551 http://dx.doi.org/10.1186/1476-7120-5-28 |
_version_ | 1782137017878970368 |
---|---|
author | Galderisi, Maurizio Cattaneo, Fabio Mondillo, Sergio |
author_facet | Galderisi, Maurizio Cattaneo, Fabio Mondillo, Sergio |
author_sort | Galderisi, Maurizio |
collection | PubMed |
description | Morbidity and mortality rates are higher in patients with severe left ventricular (LV) systolic dysfunction and ECG-derived prolonged QRS interval than in those with normal QRS duration. QRS duration is currently used on the grounds that it reflects the presence of ventricular dyssynchrony. However, 30–40% of patients selected on the basis of a prolonged QRS do not receive benefit by cardiac resynchronization therapy (CRT) since they do not show any significant inverse LV remodeling and QRS duration does not accurately distinguish responders to CRT. Consequently, mechanical dyssynchrony (particularly intra-ventricular dyssynchrony) seems to be much more important than electrical dyssinchrony. Pre- and post-echocardiographic assessment should require the combination of conventional and specific applications ranging from M-mode and pulsed/continuous Doppler, to pulsed Tissue Doppler, the off-line analysis of colour Tissue Velocity Imaging, Strain Rate Imaging, and real time three-dimensional reconstruction However, there is not no consensus about the best approach and the best ultrasound parameter for selecting candidates to CRT and ECG representation of abnormal cardiac conduction still remains as the main criterion in guidelines. This review is a practical update of ultrasound methods and measurements of atrio-ventricular, inter-ventricular and intra-ventricular dyssynchrony and describes experiences which used either conventional Doppler echocardiography and more advanced techniques. By these experiences, the global amount of LV dyssynchrony seems to be critical: the greater intra-ventricular dyssynchrony, the higher the possibility of significant LV inverse remodeling. After CRT, it is necessary also to evaluate the optimal atrio-ventricular delay and ventricular-ventricular delay setting that maximizes LV systolic function. |
format | Text |
id | pubmed-2034540 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-20345402007-10-19 Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies Galderisi, Maurizio Cattaneo, Fabio Mondillo, Sergio Cardiovasc Ultrasound Review Morbidity and mortality rates are higher in patients with severe left ventricular (LV) systolic dysfunction and ECG-derived prolonged QRS interval than in those with normal QRS duration. QRS duration is currently used on the grounds that it reflects the presence of ventricular dyssynchrony. However, 30–40% of patients selected on the basis of a prolonged QRS do not receive benefit by cardiac resynchronization therapy (CRT) since they do not show any significant inverse LV remodeling and QRS duration does not accurately distinguish responders to CRT. Consequently, mechanical dyssynchrony (particularly intra-ventricular dyssynchrony) seems to be much more important than electrical dyssinchrony. Pre- and post-echocardiographic assessment should require the combination of conventional and specific applications ranging from M-mode and pulsed/continuous Doppler, to pulsed Tissue Doppler, the off-line analysis of colour Tissue Velocity Imaging, Strain Rate Imaging, and real time three-dimensional reconstruction However, there is not no consensus about the best approach and the best ultrasound parameter for selecting candidates to CRT and ECG representation of abnormal cardiac conduction still remains as the main criterion in guidelines. This review is a practical update of ultrasound methods and measurements of atrio-ventricular, inter-ventricular and intra-ventricular dyssynchrony and describes experiences which used either conventional Doppler echocardiography and more advanced techniques. By these experiences, the global amount of LV dyssynchrony seems to be critical: the greater intra-ventricular dyssynchrony, the higher the possibility of significant LV inverse remodeling. After CRT, it is necessary also to evaluate the optimal atrio-ventricular delay and ventricular-ventricular delay setting that maximizes LV systolic function. BioMed Central 2007-09-06 /pmc/articles/PMC2034540/ /pubmed/17822551 http://dx.doi.org/10.1186/1476-7120-5-28 Text en Copyright © 2007 Galderisi et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Galderisi, Maurizio Cattaneo, Fabio Mondillo, Sergio Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies |
title | Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies |
title_full | Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies |
title_fullStr | Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies |
title_full_unstemmed | Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies |
title_short | Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies |
title_sort | doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2034540/ https://www.ncbi.nlm.nih.gov/pubmed/17822551 http://dx.doi.org/10.1186/1476-7120-5-28 |
work_keys_str_mv | AT galderisimaurizio dopplerechocardiographyandmyocardialdyssynchronyapracticalupdateofoldandnewultrasoundtechnologies AT cattaneofabio dopplerechocardiographyandmyocardialdyssynchronyapracticalupdateofoldandnewultrasoundtechnologies AT mondillosergio dopplerechocardiographyandmyocardialdyssynchronyapracticalupdateofoldandnewultrasoundtechnologies |