Cargando…

Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints

OBJECTIVES: To generate insight into the differences between utility measures EuroQol 5D (EQ-5D), Health Utilities Index Mark II (HUI2) and Mark III (HUI3) and their impact on the incremental cost-effectiveness ratio (ICER) for hearing aid fitting METHODS: Persons with hearing complaints completed E...

Descripción completa

Detalles Bibliográficos
Autores principales: Grutters, Janneke P. C., Joore, Manuela A., van der Horst, Frans, Verschuure, Hans, Dreschler, Wouter A., Anteunis, Lucien J. C.
Formato: Texto
Lenguaje:English
Publicado: Springer Netherlands 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2039846/
https://www.ncbi.nlm.nih.gov/pubmed/17647093
http://dx.doi.org/10.1007/s11136-007-9237-x
_version_ 1782137061782847488
author Grutters, Janneke P. C.
Joore, Manuela A.
van der Horst, Frans
Verschuure, Hans
Dreschler, Wouter A.
Anteunis, Lucien J. C.
author_facet Grutters, Janneke P. C.
Joore, Manuela A.
van der Horst, Frans
Verschuure, Hans
Dreschler, Wouter A.
Anteunis, Lucien J. C.
author_sort Grutters, Janneke P. C.
collection PubMed
description OBJECTIVES: To generate insight into the differences between utility measures EuroQol 5D (EQ-5D), Health Utilities Index Mark II (HUI2) and Mark III (HUI3) and their impact on the incremental cost-effectiveness ratio (ICER) for hearing aid fitting METHODS: Persons with hearing complaints completed EQ-5D, HUI2 and HUI3 at baseline and, when applicable, after hearing aid fitting. Practicality, construct validity, agreement, responsiveness and impact on the ICER were examined. RESULTS: All measures had high completion rates. HUI3 was capable of discriminating between clinically distinctive groups. Utility scores (n = 315) for EQ-5D UK and Dutch tariff (0.83; 0.86), HUI2 (0.77) and HUI3 (0.61) were significantly different, agreement was low to moderate. Change after hearing aid fitting (n = 70) for HUI2 (0.07) and HUI3 (0.12) was statistically significant, unlike the EQ-5D UK (0.01) and Dutch (0.00) tariff. ICERs varied from €647,209/QALY for the EQ-5D Dutch tariff to €15,811/QALY for HUI3. CONCLUSION: Utility scores, utility gain and ICERs heavily depend on the measure that is used to elicit them. This study indicates HUI3 as the instrument of first choice when measuring utility in a population with hearing complaints, but emphasizes the importance of a clear notion of what constitutes utility with regard to economic analyses.
format Text
id pubmed-2039846
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-20398462007-10-29 Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints Grutters, Janneke P. C. Joore, Manuela A. van der Horst, Frans Verschuure, Hans Dreschler, Wouter A. Anteunis, Lucien J. C. Qual Life Res Article OBJECTIVES: To generate insight into the differences between utility measures EuroQol 5D (EQ-5D), Health Utilities Index Mark II (HUI2) and Mark III (HUI3) and their impact on the incremental cost-effectiveness ratio (ICER) for hearing aid fitting METHODS: Persons with hearing complaints completed EQ-5D, HUI2 and HUI3 at baseline and, when applicable, after hearing aid fitting. Practicality, construct validity, agreement, responsiveness and impact on the ICER were examined. RESULTS: All measures had high completion rates. HUI3 was capable of discriminating between clinically distinctive groups. Utility scores (n = 315) for EQ-5D UK and Dutch tariff (0.83; 0.86), HUI2 (0.77) and HUI3 (0.61) were significantly different, agreement was low to moderate. Change after hearing aid fitting (n = 70) for HUI2 (0.07) and HUI3 (0.12) was statistically significant, unlike the EQ-5D UK (0.01) and Dutch (0.00) tariff. ICERs varied from €647,209/QALY for the EQ-5D Dutch tariff to €15,811/QALY for HUI3. CONCLUSION: Utility scores, utility gain and ICERs heavily depend on the measure that is used to elicit them. This study indicates HUI3 as the instrument of first choice when measuring utility in a population with hearing complaints, but emphasizes the importance of a clear notion of what constitutes utility with regard to economic analyses. Springer Netherlands 2007-07-24 2007-10 /pmc/articles/PMC2039846/ /pubmed/17647093 http://dx.doi.org/10.1007/s11136-007-9237-x Text en © Springer Science+Business Media B.V. 2007
spellingShingle Article
Grutters, Janneke P. C.
Joore, Manuela A.
van der Horst, Frans
Verschuure, Hans
Dreschler, Wouter A.
Anteunis, Lucien J. C.
Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
title Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
title_full Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
title_fullStr Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
title_full_unstemmed Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
title_short Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints
title_sort choosing between measures: comparison of eq-5d, hui2 and hui3 in persons with hearing complaints
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2039846/
https://www.ncbi.nlm.nih.gov/pubmed/17647093
http://dx.doi.org/10.1007/s11136-007-9237-x
work_keys_str_mv AT gruttersjannekepc choosingbetweenmeasurescomparisonofeq5dhui2andhui3inpersonswithhearingcomplaints
AT jooremanuelaa choosingbetweenmeasurescomparisonofeq5dhui2andhui3inpersonswithhearingcomplaints
AT vanderhorstfrans choosingbetweenmeasurescomparisonofeq5dhui2andhui3inpersonswithhearingcomplaints
AT verschuurehans choosingbetweenmeasurescomparisonofeq5dhui2andhui3inpersonswithhearingcomplaints
AT dreschlerwoutera choosingbetweenmeasurescomparisonofeq5dhui2andhui3inpersonswithhearingcomplaints
AT anteunislucienjc choosingbetweenmeasurescomparisonofeq5dhui2andhui3inpersonswithhearingcomplaints