Cargando…

A method for improving SELDI-TOF mass spectrometry data quality

BACKGROUND: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) is a powerful tool for rapidly generating high-throughput protein profiles from a large number of samples. However, the events that occur between the first and last sample run are likely to intro...

Descripción completa

Detalles Bibliográficos
Autores principales: Whistler, Toni, Rollin, Dominique, Vernon, Suzanne D
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2040139/
https://www.ncbi.nlm.nih.gov/pubmed/17803814
http://dx.doi.org/10.1186/1477-5956-5-14
_version_ 1782137070329790464
author Whistler, Toni
Rollin, Dominique
Vernon, Suzanne D
author_facet Whistler, Toni
Rollin, Dominique
Vernon, Suzanne D
author_sort Whistler, Toni
collection PubMed
description BACKGROUND: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) is a powerful tool for rapidly generating high-throughput protein profiles from a large number of samples. However, the events that occur between the first and last sample run are likely to introduce technical variation in the results. METHODS: We fractionated and analyzed quality control and investigational serum samples on 3 Protein Chips and used statistical methods to identify poor-quality spectra and to identify and reduce technical variation. RESULTS: Using diagnostic plots, we were able to visually depict all spectra and to identify and remove those that were of poor quality. We detected a technical variation associated with when the samples were run (referred to as batch effect) and corrected for this variation using analysis of variance. These corrections increased the number of peaks that were reproducibly detected. CONCLUSION: By removing poor-quality, outlier spectra, we were able to increase peak detection, and by reducing the variance introduced when samples are processed and analyzed in batches, we were able to increase the reproducibility of peak detection.
format Text
id pubmed-2040139
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-20401392007-10-23 A method for improving SELDI-TOF mass spectrometry data quality Whistler, Toni Rollin, Dominique Vernon, Suzanne D Proteome Sci Methodology BACKGROUND: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) is a powerful tool for rapidly generating high-throughput protein profiles from a large number of samples. However, the events that occur between the first and last sample run are likely to introduce technical variation in the results. METHODS: We fractionated and analyzed quality control and investigational serum samples on 3 Protein Chips and used statistical methods to identify poor-quality spectra and to identify and reduce technical variation. RESULTS: Using diagnostic plots, we were able to visually depict all spectra and to identify and remove those that were of poor quality. We detected a technical variation associated with when the samples were run (referred to as batch effect) and corrected for this variation using analysis of variance. These corrections increased the number of peaks that were reproducibly detected. CONCLUSION: By removing poor-quality, outlier spectra, we were able to increase peak detection, and by reducing the variance introduced when samples are processed and analyzed in batches, we were able to increase the reproducibility of peak detection. BioMed Central 2007-09-05 /pmc/articles/PMC2040139/ /pubmed/17803814 http://dx.doi.org/10.1186/1477-5956-5-14 Text en Copyright © 2007 Whistler et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Whistler, Toni
Rollin, Dominique
Vernon, Suzanne D
A method for improving SELDI-TOF mass spectrometry data quality
title A method for improving SELDI-TOF mass spectrometry data quality
title_full A method for improving SELDI-TOF mass spectrometry data quality
title_fullStr A method for improving SELDI-TOF mass spectrometry data quality
title_full_unstemmed A method for improving SELDI-TOF mass spectrometry data quality
title_short A method for improving SELDI-TOF mass spectrometry data quality
title_sort method for improving seldi-tof mass spectrometry data quality
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2040139/
https://www.ncbi.nlm.nih.gov/pubmed/17803814
http://dx.doi.org/10.1186/1477-5956-5-14
work_keys_str_mv AT whistlertoni amethodforimprovingselditofmassspectrometrydataquality
AT rollindominique amethodforimprovingselditofmassspectrometrydataquality
AT vernonsuzanned amethodforimprovingselditofmassspectrometrydataquality
AT whistlertoni methodforimprovingselditofmassspectrometrydataquality
AT rollindominique methodforimprovingselditofmassspectrometrydataquality
AT vernonsuzanned methodforimprovingselditofmassspectrometrydataquality