Cargando…

MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study

Background: The audible release or cracking sound associated with spinal manipulation is familiar to practitioners of spinal manipulative therapy. Furthermore, some authors believe the articular crack to be at least in part responsible for the therapeutic benefits derived from spinal manipulative th...

Descripción completa

Detalles Bibliográficos
Autor principal: Reggars, John W.
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2051087/
https://www.ncbi.nlm.nih.gov/pubmed/17987189
_version_ 1782137205239578624
author Reggars, John W.
author_facet Reggars, John W.
author_sort Reggars, John W.
collection PubMed
description Background: The audible release or cracking sound associated with spinal manipulation is familiar to practitioners of spinal manipulative therapy. Furthermore, some authors believe the articular crack to be at least in part responsible for the therapeutic benefits derived from spinal manipulative therapy. Although some research has been directed towards the investigation of some aspects of this phenomenon, little research has be conducted in order to establish from which side and vertebral level the audible release occurs during the manipulative process. Objective: To assess the reliability and accuracy of multiple surface mounted microphones to detect the audible release of the target joint during manipulation of the third metacarpophalangeal joint. Design: Observational study. Setting: Private practice of chiropractic, Ringwood, Victoria, Australia. Participants: Twenty volunteers recruited from staff and patients of the private practice of chiropractic. Method: Eight omnidirectional microphones were affixed to the palmar surface of the hand. Microphone No.1 was positioned directly over the third metacarpophalangeal joint while the remaining microphones were arranged in a uniform pattern over the palmar surface of the hand. Manipulation in the form of long axis traction was then applied to the third metacarpophalangeal joint. Where an audible release was associated with the manipulation the resultant signals were captured via computer and stored for later analysis. Main Outcome Measure: A difference of greater than one volt in peak amplitude between the microphone positioned over the target joint and the other microphones. The student's t-test was then applied to the data in order to determine if the mean output of the target joint microphone was statistically different to the mean output of the other microphones. Results: A total of eighteen manipulations resulted in nineteen audible release signals. The mean voltage of channel 1 was consistently greater than all the other channels in this group of subjects. This difference was statistically significant for all the channels. Conclusion: This research suggests that multiple surface mounted microphones are capable of consistently detecting the audible release from the target joint, with manipulation directed to the third MCP joint. It is hoped that this method will be able to be applied to the audible release associated with spinal manipulative therapy and a better understanding of the manipulative process will ensue.
format Text
id pubmed-2051087
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-20510872007-11-06 MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study Reggars, John W. Australas Chiropr Osteopathy Article Background: The audible release or cracking sound associated with spinal manipulation is familiar to practitioners of spinal manipulative therapy. Furthermore, some authors believe the articular crack to be at least in part responsible for the therapeutic benefits derived from spinal manipulative therapy. Although some research has been directed towards the investigation of some aspects of this phenomenon, little research has be conducted in order to establish from which side and vertebral level the audible release occurs during the manipulative process. Objective: To assess the reliability and accuracy of multiple surface mounted microphones to detect the audible release of the target joint during manipulation of the third metacarpophalangeal joint. Design: Observational study. Setting: Private practice of chiropractic, Ringwood, Victoria, Australia. Participants: Twenty volunteers recruited from staff and patients of the private practice of chiropractic. Method: Eight omnidirectional microphones were affixed to the palmar surface of the hand. Microphone No.1 was positioned directly over the third metacarpophalangeal joint while the remaining microphones were arranged in a uniform pattern over the palmar surface of the hand. Manipulation in the form of long axis traction was then applied to the third metacarpophalangeal joint. Where an audible release was associated with the manipulation the resultant signals were captured via computer and stored for later analysis. Main Outcome Measure: A difference of greater than one volt in peak amplitude between the microphone positioned over the target joint and the other microphones. The student's t-test was then applied to the data in order to determine if the mean output of the target joint microphone was statistically different to the mean output of the other microphones. Results: A total of eighteen manipulations resulted in nineteen audible release signals. The mean voltage of channel 1 was consistently greater than all the other channels in this group of subjects. This difference was statistically significant for all the channels. Conclusion: This research suggests that multiple surface mounted microphones are capable of consistently detecting the audible release from the target joint, with manipulation directed to the third MCP joint. It is hoped that this method will be able to be applied to the audible release associated with spinal manipulative therapy and a better understanding of the manipulative process will ensue. BioMed Central 1999-03 /pmc/articles/PMC2051087/ /pubmed/17987189 Text en Chiropractic & Osteopathic College of Australasia
spellingShingle Article
Reggars, John W.
MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study
title MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study
title_full MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study
title_fullStr MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study
title_full_unstemmed MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study
title_short MULTIPLE CHANNEL RECORDING OF THE ARTICULAR CRACK ASSOCIATED WITH MANIPULATION OF THE METACARPOPHALANGEAL JOINT: An Observational Study
title_sort multiple channel recording of the articular crack associated with manipulation of the metacarpophalangeal joint: an observational study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2051087/
https://www.ncbi.nlm.nih.gov/pubmed/17987189
work_keys_str_mv AT reggarsjohnw multiplechannelrecordingofthearticularcrackassociatedwithmanipulationofthemetacarpophalangealjointanobservationalstudy