Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system

BACKGROUND: Carotid intima-media thickness (CIMT) measured by B-mode ultrasonography is a marker of atherosclerosis and is commonly used as an outcome in intervention trials. We have developed DICOM-based software that measures CIMT rapidly on multiple end-diastolic image frames. The aims of this st...

Descripción completa

Detalles Bibliográficos
Autores principales: Potter, Kathleen, Green, Daniel J, Reed, Christopher J, Woodman, Richard J, Watts, Gerald F, McQuillan, Brendan M, Burke, Valerie, Hankey, Graeme J, Arnolda, Leonard F
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2100042/
https://www.ncbi.nlm.nih.gov/pubmed/17892537
http://dx.doi.org/10.1186/1476-7120-5-29
_version_ 1782138322412371968
author Potter, Kathleen
Green, Daniel J
Reed, Christopher J
Woodman, Richard J
Watts, Gerald F
McQuillan, Brendan M
Burke, Valerie
Hankey, Graeme J
Arnolda, Leonard F
author_facet Potter, Kathleen
Green, Daniel J
Reed, Christopher J
Woodman, Richard J
Watts, Gerald F
McQuillan, Brendan M
Burke, Valerie
Hankey, Graeme J
Arnolda, Leonard F
author_sort Potter, Kathleen
collection PubMed
description BACKGROUND: Carotid intima-media thickness (CIMT) measured by B-mode ultrasonography is a marker of atherosclerosis and is commonly used as an outcome in intervention trials. We have developed DICOM-based software that measures CIMT rapidly on multiple end-diastolic image frames. The aims of this study were to compare the performance of our new software with older bitmap-based CIMT measurement software and to determine whether a ten-fold increase in the number of measurements used to calculate mean CIMT would improve reproducibility. METHODS: Two independent sonographers recorded replicate carotid scans in thirty volunteers and two blinded observers measured CIMT off-line using the new DICOM-based software and older bitmap-based software. A Bland-Altman plot was used to compare CIMT results from the two software programs and t-tests were used to compare analysis times. F-tests were used to compare the co-efficients of variation (CVs) from a standard six-frame measurement protocol with CVs from a sixty-frame measurement protocol. Ordinary least products (OLP) regression was used to test for sonographer and observer biases. RESULTS: The new DICOM-based software was much faster than older bitmap-based software (average measurement time for one scan 3.4 ± 0.6 minutes versus 8.4 ± 1.8 minutes, p < 0.0001) but CIMT measurements were larger than those made using the alternative software (+0.02 mm, 95%CI 0.01–0.03 mm). The sixty-frame measurement protocol had worse reproducibility than the six-frame protocol (inter-observer CV 5.1% vs 3.5%, p = 0.004) and inter and intra-observer biases were more pronounced in the sixty-frame than the six-frame results. CONCLUSION: While the use of DICOM-based software significantly reduced analysis time, a ten-fold increase in the number of measurements used to calculate CIMT did not improve reproducibility. In addition, we found that observer biases caused differences in mean CIMT of a magnitude commonly reported as significant in intervention trials. Our results highlight the importance of good study design with concurrent controls and the need to ensure that no observer drift occurs between baseline and follow-up measurements when CIMT is used to monitor the effect of an intervention.
format Text
id pubmed-2100042
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-21000422007-12-01 Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system Potter, Kathleen Green, Daniel J Reed, Christopher J Woodman, Richard J Watts, Gerald F McQuillan, Brendan M Burke, Valerie Hankey, Graeme J Arnolda, Leonard F Cardiovasc Ultrasound Research BACKGROUND: Carotid intima-media thickness (CIMT) measured by B-mode ultrasonography is a marker of atherosclerosis and is commonly used as an outcome in intervention trials. We have developed DICOM-based software that measures CIMT rapidly on multiple end-diastolic image frames. The aims of this study were to compare the performance of our new software with older bitmap-based CIMT measurement software and to determine whether a ten-fold increase in the number of measurements used to calculate mean CIMT would improve reproducibility. METHODS: Two independent sonographers recorded replicate carotid scans in thirty volunteers and two blinded observers measured CIMT off-line using the new DICOM-based software and older bitmap-based software. A Bland-Altman plot was used to compare CIMT results from the two software programs and t-tests were used to compare analysis times. F-tests were used to compare the co-efficients of variation (CVs) from a standard six-frame measurement protocol with CVs from a sixty-frame measurement protocol. Ordinary least products (OLP) regression was used to test for sonographer and observer biases. RESULTS: The new DICOM-based software was much faster than older bitmap-based software (average measurement time for one scan 3.4 ± 0.6 minutes versus 8.4 ± 1.8 minutes, p < 0.0001) but CIMT measurements were larger than those made using the alternative software (+0.02 mm, 95%CI 0.01–0.03 mm). The sixty-frame measurement protocol had worse reproducibility than the six-frame protocol (inter-observer CV 5.1% vs 3.5%, p = 0.004) and inter and intra-observer biases were more pronounced in the sixty-frame than the six-frame results. CONCLUSION: While the use of DICOM-based software significantly reduced analysis time, a ten-fold increase in the number of measurements used to calculate CIMT did not improve reproducibility. In addition, we found that observer biases caused differences in mean CIMT of a magnitude commonly reported as significant in intervention trials. Our results highlight the importance of good study design with concurrent controls and the need to ensure that no observer drift occurs between baseline and follow-up measurements when CIMT is used to monitor the effect of an intervention. BioMed Central 2007-09-24 /pmc/articles/PMC2100042/ /pubmed/17892537 http://dx.doi.org/10.1186/1476-7120-5-29 Text en Copyright © 2007 Potter et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Potter, Kathleen
Green, Daniel J
Reed, Christopher J
Woodman, Richard J
Watts, Gerald F
McQuillan, Brendan M
Burke, Valerie
Hankey, Graeme J
Arnolda, Leonard F
Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system
title Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system
title_full Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system
title_fullStr Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system
title_full_unstemmed Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system
title_short Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system
title_sort carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a dicom-based software system
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2100042/
https://www.ncbi.nlm.nih.gov/pubmed/17892537
http://dx.doi.org/10.1186/1476-7120-5-29
work_keys_str_mv AT potterkathleen carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT greendanielj carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT reedchristopherj carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT woodmanrichardj carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT wattsgeraldf carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT mcquillanbrendanm carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT burkevalerie carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT hankeygraemej carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem
AT arnoldaleonardf carotidintimamedialthicknessmeasuredonmultipleultrasoundframesevaluationofadicombasedsoftwaresystem