Cargando…

A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER

A reliable knowledge of the thickness of the alveolo-capillary "membrane" or air-blood barrier is of physiologic interest since it is intimately related to a quantitative estimation of such functional events as gas diffusion or tissue metabolism in the lung. The characteristic thickness of...

Descripción completa

Detalles Bibliográficos
Autores principales: Weibel, Ewald R., Knight, Bruce W.
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1964
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2106384/
https://www.ncbi.nlm.nih.gov/pubmed/14189911
_version_ 1782138479417753600
author Weibel, Ewald R.
Knight, Bruce W.
author_facet Weibel, Ewald R.
Knight, Bruce W.
author_sort Weibel, Ewald R.
collection PubMed
description A reliable knowledge of the thickness of the alveolo-capillary "membrane" or air-blood barrier is of physiologic interest since it is intimately related to a quantitative estimation of such functional events as gas diffusion or tissue metabolism in the lung. The characteristic thickness of the air-blood barrier with respect to gas diffusion is its harmonic mean thickness, while the arithmetic mean thickness is related to the mass of tissue building the barrier and consuming oxygen in the lung. Two morphometric methods are proposed by which these two dimensions can be estimated from random measurements in the electron microscope in a reliable, simple, and efficient manner. By applying these methods to three rat lungs the arithmetic mean thickness of the barrier was found to measure 1.25 µ, the harmonic mean thickness, 0.57 µ. On the basis of these measurements a geometric model of the barrier in the form of a corrugated membrane was derived. Its dimensions showed close similarity to those of the natural barrier. This analysis suggested furthermore that the gas conductance of the barrier is nearly optimal if one considers the mass of tissue and the minimal barrier thickness as fixed properties which are determined by other functional requirements on the alveolo-capillary membrane.
format Text
id pubmed-2106384
institution National Center for Biotechnology Information
language English
publishDate 1964
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21063842008-05-01 A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER Weibel, Ewald R. Knight, Bruce W. J Cell Biol Article A reliable knowledge of the thickness of the alveolo-capillary "membrane" or air-blood barrier is of physiologic interest since it is intimately related to a quantitative estimation of such functional events as gas diffusion or tissue metabolism in the lung. The characteristic thickness of the air-blood barrier with respect to gas diffusion is its harmonic mean thickness, while the arithmetic mean thickness is related to the mass of tissue building the barrier and consuming oxygen in the lung. Two morphometric methods are proposed by which these two dimensions can be estimated from random measurements in the electron microscope in a reliable, simple, and efficient manner. By applying these methods to three rat lungs the arithmetic mean thickness of the barrier was found to measure 1.25 µ, the harmonic mean thickness, 0.57 µ. On the basis of these measurements a geometric model of the barrier in the form of a corrugated membrane was derived. Its dimensions showed close similarity to those of the natural barrier. This analysis suggested furthermore that the gas conductance of the barrier is nearly optimal if one considers the mass of tissue and the minimal barrier thickness as fixed properties which are determined by other functional requirements on the alveolo-capillary membrane. The Rockefeller University Press 1964-06-01 /pmc/articles/PMC2106384/ /pubmed/14189911 Text en Copyright © 1964 by The Rockefeller Institute Press This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
Weibel, Ewald R.
Knight, Bruce W.
A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER
title A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER
title_full A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER
title_fullStr A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER
title_full_unstemmed A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER
title_short A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER
title_sort morphometric study on the thickness of the pulmonary air-blood barrier
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2106384/
https://www.ncbi.nlm.nih.gov/pubmed/14189911
work_keys_str_mv AT weibelewaldr amorphometricstudyonthethicknessofthepulmonaryairbloodbarrier
AT knightbrucew amorphometricstudyonthethicknessofthepulmonaryairbloodbarrier
AT weibelewaldr morphometricstudyonthethicknessofthepulmonaryairbloodbarrier
AT knightbrucew morphometricstudyonthethicknessofthepulmonaryairbloodbarrier