Cargando…
THE M BAND : Studies with Fluorescent Antibody Staining
The M band can be extracted from fibrils suspended in 5 mM Tris buffer, pH 8.0, for 15 min. The M band is completely removed only from fibrils of sarcomere lengths greater than 2.1 µ. Extraction does not alter the fluorescent antimyosin staining pattern of the A band, thus providing strong evidence...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1971
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2108176/ https://www.ncbi.nlm.nih.gov/pubmed/4101522 |
Sumario: | The M band can be extracted from fibrils suspended in 5 mM Tris buffer, pH 8.0, for 15 min. The M band is completely removed only from fibrils of sarcomere lengths greater than 2.1 µ. Extraction does not alter the fluorescent antimyosin staining pattern of the A band, thus providing strong evidence that no alteration of the structural integrity of the thick filament has occurred. Fluorescent antibody staining of the M band of unextracted fibrils can be prevented specifically by absorbing the fluorescent antibody with extracted M band material prior to staining. This verifies the specificity of the extraction procedure. |
---|