Cargando…
Spectroscopic assays for measuring quantities of erythrocyte membrane "halves"
The quantities of outer and inner"halves" produced by freeze-fracturing human erythrocyte membranes have been measured by visible and fluorescence spectroscopy. Assays have been developed that are based on the use of two membrane surface markers: hemoglobin (Hb), a native marker for the cy...
Formato: | Texto |
---|---|
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1982
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2111999/ https://www.ncbi.nlm.nih.gov/pubmed/7056801 |
_version_ | 1782139854814969856 |
---|---|
collection | PubMed |
description | The quantities of outer and inner"halves" produced by freeze-fracturing human erythrocyte membranes have been measured by visible and fluorescence spectroscopy. Assays have been developed that are based on the use of two membrane surface markers: hemoglobin (Hb), a native marker for the cytoplasmic side of the membrane, and fluoresceinated concanavalin A (FITC-Con-A), a marker for the extracellular side. Hb absorbance is proportional to the fraction of cytoplasmic "half" membranes, and FITC fluorescence is proportional to the fraction of extracellular "halves." A procedure is described for the preparation of surface-labeled, intact erythrocytes suitable for the formation of homogeneous, planar cell monolayers of square-centimeter dimensions on polylysine-treated glass (PL-glass). Cell monolayers were frozen and fractured, and the fractions of absorbance and fluorescence in each of the two split portions determined. The PL-glass portion of membrane contained a substantially higher ratio of fluorescence to absorbance than unsplit controls, and its paired portion, a complementary lower ratio, demonstrating that the PL-glass portion was significantly enriched in extracellular "half" membrane. Experiments investigating split membrane recovery show that the double labeled membrane splitting technique is well suited to analysis of the transmembrane distribution of membrane lipids and polypeptides using methods that do not require quantitation by electron microscopy. |
format | Text |
id | pubmed-2111999 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1982 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-21119992008-05-01 Spectroscopic assays for measuring quantities of erythrocyte membrane "halves" J Cell Biol Articles The quantities of outer and inner"halves" produced by freeze-fracturing human erythrocyte membranes have been measured by visible and fluorescence spectroscopy. Assays have been developed that are based on the use of two membrane surface markers: hemoglobin (Hb), a native marker for the cytoplasmic side of the membrane, and fluoresceinated concanavalin A (FITC-Con-A), a marker for the extracellular side. Hb absorbance is proportional to the fraction of cytoplasmic "half" membranes, and FITC fluorescence is proportional to the fraction of extracellular "halves." A procedure is described for the preparation of surface-labeled, intact erythrocytes suitable for the formation of homogeneous, planar cell monolayers of square-centimeter dimensions on polylysine-treated glass (PL-glass). Cell monolayers were frozen and fractured, and the fractions of absorbance and fluorescence in each of the two split portions determined. The PL-glass portion of membrane contained a substantially higher ratio of fluorescence to absorbance than unsplit controls, and its paired portion, a complementary lower ratio, demonstrating that the PL-glass portion was significantly enriched in extracellular "half" membrane. Experiments investigating split membrane recovery show that the double labeled membrane splitting technique is well suited to analysis of the transmembrane distribution of membrane lipids and polypeptides using methods that do not require quantitation by electron microscopy. The Rockefeller University Press 1982-01-01 /pmc/articles/PMC2111999/ /pubmed/7056801 Text en This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/). |
spellingShingle | Articles Spectroscopic assays for measuring quantities of erythrocyte membrane "halves" |
title | Spectroscopic assays for measuring quantities of erythrocyte membrane "halves" |
title_full | Spectroscopic assays for measuring quantities of erythrocyte membrane "halves" |
title_fullStr | Spectroscopic assays for measuring quantities of erythrocyte membrane "halves" |
title_full_unstemmed | Spectroscopic assays for measuring quantities of erythrocyte membrane "halves" |
title_short | Spectroscopic assays for measuring quantities of erythrocyte membrane "halves" |
title_sort | spectroscopic assays for measuring quantities of erythrocyte membrane "halves" |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2111999/ https://www.ncbi.nlm.nih.gov/pubmed/7056801 |