Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6

The acidification of various ligands was measured on a cell by cell basis for cell suspensions by correlated dual fluorescence flow cytometry. Mouse 3T3 cells were incubated with a mixture of fluorescein- and rhodamine-conjugated ligands, and the ratio of fluorescein and rhodamine fluorescence was u...

Descripción completa

Detalles Bibliográficos
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1984
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2113196/
https://www.ncbi.nlm.nih.gov/pubmed/6144684
_version_ 1782140129022836736
collection PubMed
description The acidification of various ligands was measured on a cell by cell basis for cell suspensions by correlated dual fluorescence flow cytometry. Mouse 3T3 cells were incubated with a mixture of fluorescein- and rhodamine-conjugated ligands, and the ratio of fluorescein and rhodamine fluorescence was used as a measure of endosome pH. The calibration of this ratio by both fluorometry and flow cytometry is described. Dual parameter histograms of average endosome pH per cell versus amount of internalization were calculated from this data, for samples in the absence and presence of chloroquine added to neutralize acidic cellular vesicles. The kinetics of acidification of insulin were measured and compared with previous results obtained with the chloroquine ratio technique. Rapid acidification of internalized ligand was observed both for insulin, which was mostly internalized via nonspecific pathways, and for alpha 2-macroglobulin, which was mainly internalized by specific receptor-mediated endocytosis. The average pH observed for internalized insulin was less than pH 6 within 10 min after addition of insulin. At 30 min, the average pH began to decrease to approximately pH 5, presumably because of fusion of endosomes with lysosomes.
format Text
id pubmed-2113196
institution National Center for Biotechnology Information
language English
publishDate 1984
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21131962008-05-01 Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6 J Cell Biol Articles The acidification of various ligands was measured on a cell by cell basis for cell suspensions by correlated dual fluorescence flow cytometry. Mouse 3T3 cells were incubated with a mixture of fluorescein- and rhodamine-conjugated ligands, and the ratio of fluorescein and rhodamine fluorescence was used as a measure of endosome pH. The calibration of this ratio by both fluorometry and flow cytometry is described. Dual parameter histograms of average endosome pH per cell versus amount of internalization were calculated from this data, for samples in the absence and presence of chloroquine added to neutralize acidic cellular vesicles. The kinetics of acidification of insulin were measured and compared with previous results obtained with the chloroquine ratio technique. Rapid acidification of internalized ligand was observed both for insulin, which was mostly internalized via nonspecific pathways, and for alpha 2-macroglobulin, which was mainly internalized by specific receptor-mediated endocytosis. The average pH observed for internalized insulin was less than pH 6 within 10 min after addition of insulin. At 30 min, the average pH began to decrease to approximately pH 5, presumably because of fusion of endosomes with lysosomes. The Rockefeller University Press 1984-05-01 /pmc/articles/PMC2113196/ /pubmed/6144684 Text en This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Articles
Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6
title Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6
title_full Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6
title_fullStr Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6
title_full_unstemmed Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6
title_short Endosome pH measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to pH 6
title_sort endosome ph measured in single cells by dual fluorescence flow cytometry: rapid acidification of insulin to ph 6
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2113196/
https://www.ncbi.nlm.nih.gov/pubmed/6144684