Cargando…
STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS.
This investigation comprises a study of venous pulse, carotid, cardiographic, and heart sound records from twenty-one men with normal hearts. The heart sounds were recorded by the method of Einthoven. When correction is made for transmission, the first heart sound begins, on an average, 0.131 of a s...
Autor principal: | |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1911
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2124846/ https://www.ncbi.nlm.nih.gov/pubmed/19867499 |
_version_ | 1782141757921689600 |
---|---|
author | Eyster, J. A. E. |
author_facet | Eyster, J. A. E. |
author_sort | Eyster, J. A. E. |
collection | PubMed |
description | This investigation comprises a study of venous pulse, carotid, cardiographic, and heart sound records from twenty-one men with normal hearts. The heart sounds were recorded by the method of Einthoven. When correction is made for transmission, the first heart sound begins, on an average, 0.131 of a second before the c-wave of the venous pulse, and has an average duration of 0.128 of a second. The second heart sound begins a few hundredths of a second before the v-wave and has a duration of 0.091 of a second. The third heart sound occurs shortly before or is coincident with the beginning of the h-wave. It has an average duration of about 0.03 of a second. Considerable variation from the average positions are noted in individual cases. This is especially true in the relation between the second heart sound and the v-wave. Measurements of the venous pulse and heart sound intervals show that the a-c, c-v, and v-h venous pulse intervals, the first to second and the second to third heart sound intervals, and systole tend to remain fairly constant in length when cardiac cycles of different length are considered. The v-a, h-a, and x-a venous pulse intervals, the third to first heart sound interval, and diastole tend to vary in length with variations in total length of the cycle. Records of the venous pulse and heart sound obtained from dogs show a similar relation to that found in man. The main difference observed was an earlier occurrence of the first heart sound before the c-wave of the venous pulse. |
format | Text |
id | pubmed-2124846 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1911 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-21248462008-04-18 STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS. Eyster, J. A. E. J Exp Med Article This investigation comprises a study of venous pulse, carotid, cardiographic, and heart sound records from twenty-one men with normal hearts. The heart sounds were recorded by the method of Einthoven. When correction is made for transmission, the first heart sound begins, on an average, 0.131 of a second before the c-wave of the venous pulse, and has an average duration of 0.128 of a second. The second heart sound begins a few hundredths of a second before the v-wave and has a duration of 0.091 of a second. The third heart sound occurs shortly before or is coincident with the beginning of the h-wave. It has an average duration of about 0.03 of a second. Considerable variation from the average positions are noted in individual cases. This is especially true in the relation between the second heart sound and the v-wave. Measurements of the venous pulse and heart sound intervals show that the a-c, c-v, and v-h venous pulse intervals, the first to second and the second to third heart sound intervals, and systole tend to remain fairly constant in length when cardiac cycles of different length are considered. The v-a, h-a, and x-a venous pulse intervals, the third to first heart sound interval, and diastole tend to vary in length with variations in total length of the cycle. Records of the venous pulse and heart sound obtained from dogs show a similar relation to that found in man. The main difference observed was an earlier occurrence of the first heart sound before the c-wave of the venous pulse. The Rockefeller University Press 1911-12-01 /pmc/articles/PMC2124846/ /pubmed/19867499 Text en Copyright © Copyright, 1911, by The Rockefeller Institute for Medical Research New York This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/). |
spellingShingle | Article Eyster, J. A. E. STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS. |
title | STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS. |
title_full | STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS. |
title_fullStr | STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS. |
title_full_unstemmed | STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS. |
title_short | STUDIES ON THE VENOUS PULSE : II. THE TIME RELATIONS OF THEVENOUS PULSE AND THE HEART SOUNDS. |
title_sort | studies on the venous pulse : ii. the time relations of thevenous pulse and the heart sounds. |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2124846/ https://www.ncbi.nlm.nih.gov/pubmed/19867499 |
work_keys_str_mv | AT eysterjae studiesonthevenouspulseiithetimerelationsofthevenouspulseandtheheartsounds |