Cargando…

STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST.

A simplified and compact agitator for growth inhibition tests with serum-leucocyte mixtures has been described. Several modifications have been made as well in the technique of the test, which have eliminated occasional irregularities that necessitated discarding the results of the individual experi...

Descripción completa

Detalles Bibliográficos
Autores principales: Robertson, Oswald H., Woo, Shutai T., Cheer, Sheo Nan
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1924
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2128583/
https://www.ncbi.nlm.nih.gov/pubmed/19868934
_version_ 1782142104578818048
author Robertson, Oswald H.
Woo, Shutai T.
Cheer, Sheo Nan
author_facet Robertson, Oswald H.
Woo, Shutai T.
Cheer, Sheo Nan
author_sort Robertson, Oswald H.
collection PubMed
description A simplified and compact agitator for growth inhibition tests with serum-leucocyte mixtures has been described. Several modifications have been made as well in the technique of the test, which have eliminated occasional irregularities that necessitated discarding the results of the individual experiment. Such irregularities were found to be due chiefly to injury of the pneumococci brought about by prolonged suspension in gelatin-Locke's solution which resulted in failure of the organisms to grow in the control serum-leucocyte tubes. This deterioration of the pneumococcus suspension may be greatly lessened or entirely prevented by the addition of a small quantity of a balanced phosphate mixture to the gelatin-Locke's solution. The use of small tubes made of Pyrex glass has also eliminated the former, not infrequent, occurrence of early hemolysis which was sometimes intense enough to disturb the results of the test. It has been found that washed rabbit leucocytes, suspended in their homologous serum, may be kept in the ice box for as long a period as 2 days without showing any apparent diminution of their functional activity in the serum-leucocyte test.
format Text
id pubmed-2128583
institution National Center for Biotechnology Information
language English
publishDate 1924
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21285832008-04-18 STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST. Robertson, Oswald H. Woo, Shutai T. Cheer, Sheo Nan J Exp Med Article A simplified and compact agitator for growth inhibition tests with serum-leucocyte mixtures has been described. Several modifications have been made as well in the technique of the test, which have eliminated occasional irregularities that necessitated discarding the results of the individual experiment. Such irregularities were found to be due chiefly to injury of the pneumococci brought about by prolonged suspension in gelatin-Locke's solution which resulted in failure of the organisms to grow in the control serum-leucocyte tubes. This deterioration of the pneumococcus suspension may be greatly lessened or entirely prevented by the addition of a small quantity of a balanced phosphate mixture to the gelatin-Locke's solution. The use of small tubes made of Pyrex glass has also eliminated the former, not infrequent, occurrence of early hemolysis which was sometimes intense enough to disturb the results of the test. It has been found that washed rabbit leucocytes, suspended in their homologous serum, may be kept in the ice box for as long a period as 2 days without showing any apparent diminution of their functional activity in the serum-leucocyte test. The Rockefeller University Press 1924-09-30 /pmc/articles/PMC2128583/ /pubmed/19868934 Text en Copyright © Copyright, 1924, by The Rockefeller Institute for Medical Research New York This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
Robertson, Oswald H.
Woo, Shutai T.
Cheer, Sheo Nan
STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST.
title STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST.
title_full STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST.
title_fullStr STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST.
title_full_unstemmed STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST.
title_short STUDIES ON PNEUMOCOCCUS GROWTH INHIBITION : IV. A SIMPLIFIED AGITATOR FOR GROWTH INHIBITION TESTS WITH SERUM-LEUCOCYTE MIXTURES; AND CERTAIN MODIFICATIONS IN THE TECHNIQUE OF THE TEST.
title_sort studies on pneumococcus growth inhibition : iv. a simplified agitator for growth inhibition tests with serum-leucocyte mixtures; and certain modifications in the technique of the test.
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2128583/
https://www.ncbi.nlm.nih.gov/pubmed/19868934
work_keys_str_mv AT robertsonoswaldh studiesonpneumococcusgrowthinhibitionivasimplifiedagitatorforgrowthinhibitiontestswithserumleucocytemixturesandcertainmodificationsinthetechniqueofthetest
AT wooshutait studiesonpneumococcusgrowthinhibitionivasimplifiedagitatorforgrowthinhibitiontestswithserumleucocytemixturesandcertainmodificationsinthetechniqueofthetest
AT cheersheonan studiesonpneumococcusgrowthinhibitionivasimplifiedagitatorforgrowthinhibitiontestswithserumleucocytemixturesandcertainmodificationsinthetechniqueofthetest