Cargando…
DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR
1. Triethylene glycol in excess of saturation, introduced as a vapor into a cloud chamber in which a dynamic cloud of either meningopneumonitis virus or psittacosis virus was developed simultaneously with, or in most instances subsequently to, the glycol cloud, induced distinct reduction in concentr...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1947
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2135670/ https://www.ncbi.nlm.nih.gov/pubmed/19871600 |
_version_ | 1782142949758337024 |
---|---|
author | Rosebury, Theodor Meiklejohn, Gordon Kingsland, Lawrence C. Boldt, Martin H. |
author_facet | Rosebury, Theodor Meiklejohn, Gordon Kingsland, Lawrence C. Boldt, Martin H. |
author_sort | Rosebury, Theodor |
collection | PubMed |
description | 1. Triethylene glycol in excess of saturation, introduced as a vapor into a cloud chamber in which a dynamic cloud of either meningopneumonitis virus or psittacosis virus was developed simultaneously with, or in most instances subsequently to, the glycol cloud, induced distinct reduction in concentration of air-home virus, as measured both by cloud sampling in capillary impingers and by exposure of mice to the cloud. The relative humidity in the chamber was held between 35 and about 60 per cent. 2. Reduction of virus concentration in samplers, in glycol runs as compared with controls, ranged from 0 to 93 per cent (average, 62 per cent). 3. Reduction of infective response in mice, based on counts of focal lesions on lung surfaces, ranged from 55 to 98 per cent (average 73 per cent). |
format | Text |
id | pubmed-2135670 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1947 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-21356702008-04-18 DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR Rosebury, Theodor Meiklejohn, Gordon Kingsland, Lawrence C. Boldt, Martin H. J Exp Med Article 1. Triethylene glycol in excess of saturation, introduced as a vapor into a cloud chamber in which a dynamic cloud of either meningopneumonitis virus or psittacosis virus was developed simultaneously with, or in most instances subsequently to, the glycol cloud, induced distinct reduction in concentration of air-home virus, as measured both by cloud sampling in capillary impingers and by exposure of mice to the cloud. The relative humidity in the chamber was held between 35 and about 60 per cent. 2. Reduction of virus concentration in samplers, in glycol runs as compared with controls, ranged from 0 to 93 per cent (average, 62 per cent). 3. Reduction of infective response in mice, based on counts of focal lesions on lung surfaces, ranged from 55 to 98 per cent (average 73 per cent). The Rockefeller University Press 1947-01-01 /pmc/articles/PMC2135670/ /pubmed/19871600 Text en Copyright © Copyright, 1947, by The Rockefeller Institute for Medical Research New York This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/). |
spellingShingle | Article Rosebury, Theodor Meiklejohn, Gordon Kingsland, Lawrence C. Boldt, Martin H. DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR |
title | DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR |
title_full | DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR |
title_fullStr | DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR |
title_full_unstemmed | DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR |
title_short | DISINFECTION OF CLOUDS OF MENINGOPNEUMONITIS AND PSITTACOSIS VIRUSES WITH TRIETHYLENE GLYCOL VAPOR |
title_sort | disinfection of clouds of meningopneumonitis and psittacosis viruses with triethylene glycol vapor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2135670/ https://www.ncbi.nlm.nih.gov/pubmed/19871600 |
work_keys_str_mv | AT roseburytheodor disinfectionofcloudsofmeningopneumonitisandpsittacosisviruseswithtriethyleneglycolvapor AT meiklejohngordon disinfectionofcloudsofmeningopneumonitisandpsittacosisviruseswithtriethyleneglycolvapor AT kingslandlawrencec disinfectionofcloudsofmeningopneumonitisandpsittacosisviruseswithtriethyleneglycolvapor AT boldtmartinh disinfectionofcloudsofmeningopneumonitisandpsittacosisviruseswithtriethyleneglycolvapor |