Cargando…

THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA

The viability of pneumococcus, Type I, sprayed into the atmosphere from a liquid suspension was measured as a function of the relative humidity. When broth, saliva, or 0.5 per cent saline solution is employed as the suspending medium, a very high mortality rate is observed at relative humidities in...

Descripción completa

Detalles Bibliográficos
Autores principales: Dunklin, Edward W., Puck, Theodore T.
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1948
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2135764/
https://www.ncbi.nlm.nih.gov/pubmed/18911172
_version_ 1782142971550892032
author Dunklin, Edward W.
Puck, Theodore T.
author_facet Dunklin, Edward W.
Puck, Theodore T.
author_sort Dunklin, Edward W.
collection PubMed
description The viability of pneumococcus, Type I, sprayed into the atmosphere from a liquid suspension was measured as a function of the relative humidity. When broth, saliva, or 0.5 per cent saline solution is employed as the suspending medium, a very high mortality rate is observed at relative humidities in the vicinity of 50 per cent. However, at humidities above or below this value the microorganisms survive for long periods. Measurement of the rate of settling of droplets employed in these experiments demonstrated that the disappearance of microorganisms from the air is a true lethal process, rather than a manifestation of aerosol collision processes. When a saline-free fluid was used, the sharp peak in death rate at intermediate relative humidities disappears. The lethal effect of intermediate relative humidities on pneumococci atomized from a saline-containing suspension is increased when the particle size of the atomized droplets is increased or when the temperature is raised. Cultures of hemolytic streptococcus group C and staphylococcus sprayed from a broth medium exhibit the same general survival pattern as a function of relative humidity although the mortality rates are smaller than that of the pneumococcus. These effects can be explained by assuming the existence of a critical degree of cellular dehydration at which microorganisms become much more sensitive to toxic agents than in states where either more or less water is bound to the cell. The results presented here may be significant in elucidating certain aspects of the epidemiology of air-borne infections.
format Text
id pubmed-2135764
institution National Center for Biotechnology Information
language English
publishDate 1948
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21357642008-04-18 THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA Dunklin, Edward W. Puck, Theodore T. J Exp Med Article The viability of pneumococcus, Type I, sprayed into the atmosphere from a liquid suspension was measured as a function of the relative humidity. When broth, saliva, or 0.5 per cent saline solution is employed as the suspending medium, a very high mortality rate is observed at relative humidities in the vicinity of 50 per cent. However, at humidities above or below this value the microorganisms survive for long periods. Measurement of the rate of settling of droplets employed in these experiments demonstrated that the disappearance of microorganisms from the air is a true lethal process, rather than a manifestation of aerosol collision processes. When a saline-free fluid was used, the sharp peak in death rate at intermediate relative humidities disappears. The lethal effect of intermediate relative humidities on pneumococci atomized from a saline-containing suspension is increased when the particle size of the atomized droplets is increased or when the temperature is raised. Cultures of hemolytic streptococcus group C and staphylococcus sprayed from a broth medium exhibit the same general survival pattern as a function of relative humidity although the mortality rates are smaller than that of the pneumococcus. These effects can be explained by assuming the existence of a critical degree of cellular dehydration at which microorganisms become much more sensitive to toxic agents than in states where either more or less water is bound to the cell. The results presented here may be significant in elucidating certain aspects of the epidemiology of air-borne infections. The Rockefeller University Press 1948-01-31 /pmc/articles/PMC2135764/ /pubmed/18911172 Text en Copyright © Copyright, 1948, by The Rockefeller Institute for Medical Research New York This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
Dunklin, Edward W.
Puck, Theodore T.
THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA
title THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA
title_full THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA
title_fullStr THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA
title_full_unstemmed THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA
title_short THE LETHAL EFFECT OF RELATIVE HUMIDITY ON AIR-BORNE BACTERIA
title_sort lethal effect of relative humidity on air-borne bacteria
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2135764/
https://www.ncbi.nlm.nih.gov/pubmed/18911172
work_keys_str_mv AT dunklinedwardw thelethaleffectofrelativehumidityonairbornebacteria
AT pucktheodoret thelethaleffectofrelativehumidityonairbornebacteria
AT dunklinedwardw lethaleffectofrelativehumidityonairbornebacteria
AT pucktheodoret lethaleffectofrelativehumidityonairbornebacteria