Cargando…

A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES

A rapid method for measuring tissue pressures has been designed. A pressure of 250 mm. Hg is imposed on a manometer. Then the system is allowed to discharge into a needle cannula inserted in the tissue. The manometer forces out fluid (about 10 c.mm.) until the pressure within it is the same as that...

Descripción completa

Detalles Bibliográficos
Autores principales: Swann, H. G., Montgomery, A. V., Davis, John C., Mickle, E. R.
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1950
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2135999/
https://www.ncbi.nlm.nih.gov/pubmed/14784541
_version_ 1782143026283413504
author Swann, H. G.
Montgomery, A. V.
Davis, John C.
Mickle, E. R.
author_facet Swann, H. G.
Montgomery, A. V.
Davis, John C.
Mickle, E. R.
author_sort Swann, H. G.
collection PubMed
description A rapid method for measuring tissue pressures has been designed. A pressure of 250 mm. Hg is imposed on a manometer. Then the system is allowed to discharge into a needle cannula inserted in the tissue. The manometer forces out fluid (about 10 c.mm.) until the pressure within it is the same as that within the tissue. Records of the pressure changes are made. Each observation takes about a minute. The method gives results that are closely comparable with other reports of tissue pressures. With this method, the pressure in the following organs of dogs was found to be: kidney, 26 mm. Hg, cerebral cortex, 0 to 5 mm., muscle, 1 to 10 mm., spleen, S to 16 mm., subcutaneous tissue, 0 to 3 mm., and liver –2 to 14 mm. The reliability of the method was tested on the kidneys of decerebrate dogs. Measurements were found to be the same within narrow limits over a period of an hour; they were the same when taken simultaneously in different regions of the same kidney or in opposite kidneys. They were independent of the volume of fluid forced into the tissue. Similar pressures were observed with 1 or 5 or 10 holes bored in the shaft of the cannulating needle. The intrarenal pressure was also measured by inserting a needle cannula into the tissue and then allowing the pressure to reach equilibrium passively with a manometer. This method gave similar results. The intrarenal pressure has now found to be the same when measured by three different technics.
format Text
id pubmed-2135999
institution National Center for Biotechnology Information
language English
publishDate 1950
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21359992008-04-17 A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES Swann, H. G. Montgomery, A. V. Davis, John C. Mickle, E. R. J Exp Med Article A rapid method for measuring tissue pressures has been designed. A pressure of 250 mm. Hg is imposed on a manometer. Then the system is allowed to discharge into a needle cannula inserted in the tissue. The manometer forces out fluid (about 10 c.mm.) until the pressure within it is the same as that within the tissue. Records of the pressure changes are made. Each observation takes about a minute. The method gives results that are closely comparable with other reports of tissue pressures. With this method, the pressure in the following organs of dogs was found to be: kidney, 26 mm. Hg, cerebral cortex, 0 to 5 mm., muscle, 1 to 10 mm., spleen, S to 16 mm., subcutaneous tissue, 0 to 3 mm., and liver –2 to 14 mm. The reliability of the method was tested on the kidneys of decerebrate dogs. Measurements were found to be the same within narrow limits over a period of an hour; they were the same when taken simultaneously in different regions of the same kidney or in opposite kidneys. They were independent of the volume of fluid forced into the tissue. Similar pressures were observed with 1 or 5 or 10 holes bored in the shaft of the cannulating needle. The intrarenal pressure was also measured by inserting a needle cannula into the tissue and then allowing the pressure to reach equilibrium passively with a manometer. This method gave similar results. The intrarenal pressure has now found to be the same when measured by three different technics. The Rockefeller University Press 1950-11-30 /pmc/articles/PMC2135999/ /pubmed/14784541 Text en Copyright © Copyright, 1950, by The Rockefeller Institute for Medical Research New York This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
Swann, H. G.
Montgomery, A. V.
Davis, John C.
Mickle, E. R.
A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES
title A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES
title_full A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES
title_fullStr A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES
title_full_unstemmed A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES
title_short A METHOD FOR RAPID MEASUREMENT OF INTRARENAL AND OTHER TISSUE PRESSURES
title_sort method for rapid measurement of intrarenal and other tissue pressures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2135999/
https://www.ncbi.nlm.nih.gov/pubmed/14784541
work_keys_str_mv AT swannhg amethodforrapidmeasurementofintrarenalandothertissuepressures
AT montgomeryav amethodforrapidmeasurementofintrarenalandothertissuepressures
AT davisjohnc amethodforrapidmeasurementofintrarenalandothertissuepressures
AT mickleer amethodforrapidmeasurementofintrarenalandothertissuepressures
AT swannhg methodforrapidmeasurementofintrarenalandothertissuepressures
AT montgomeryav methodforrapidmeasurementofintrarenalandothertissuepressures
AT davisjohnc methodforrapidmeasurementofintrarenalandothertissuepressures
AT mickleer methodforrapidmeasurementofintrarenalandothertissuepressures