Cargando…

THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA

Many of the freshly gathered cells of Valonia ventricosa have a resistance to direct current which is variable and depends on the potential applied. It is low when low potentials are applied and rises sharply at higher values. The rise may be more than 100 per cent in the cell as a whole, which is e...

Descripción completa

Detalles Bibliográficos
Autor principal: Blinks, L. R.
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1930
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2141080/
https://www.ncbi.nlm.nih.gov/pubmed/19872564
_version_ 1782144130898460672
author Blinks, L. R.
author_facet Blinks, L. R.
author_sort Blinks, L. R.
collection PubMed
description Many of the freshly gathered cells of Valonia ventricosa have a resistance to direct current which is variable and depends on the potential applied. It is low when low potentials are applied and rises sharply at higher values. The rise may be more than 100 per cent in the cell as a whole, which is equivalent to several hundred per cent in the protoplasm alone. The rise becomes less as the cells stand in the laboratory, until a maximum is reached at all applied potentials, low and high, below the breakdown value (about 100 mv.): the cells are then said to be in a constant state. During the variable state, the resistance rises when the positive current enters the protoplasm from outside, and falls when it passes out from the vacuole (this is determined by killing one end with chloroform). The rise of resistance becomes faster with closely succeeding applications of potential. This is ascribed to the removal from the protoplasm of ions to which it is reversible. There is some evidence that these may be potassium ions. Much of the apparent resistance rise may be accounted for by a back E.M.F. caused by the flow of current.
format Text
id pubmed-2141080
institution National Center for Biotechnology Information
language English
publishDate 1930
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21410802008-04-23 THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA Blinks, L. R. J Gen Physiol Article Many of the freshly gathered cells of Valonia ventricosa have a resistance to direct current which is variable and depends on the potential applied. It is low when low potentials are applied and rises sharply at higher values. The rise may be more than 100 per cent in the cell as a whole, which is equivalent to several hundred per cent in the protoplasm alone. The rise becomes less as the cells stand in the laboratory, until a maximum is reached at all applied potentials, low and high, below the breakdown value (about 100 mv.): the cells are then said to be in a constant state. During the variable state, the resistance rises when the positive current enters the protoplasm from outside, and falls when it passes out from the vacuole (this is determined by killing one end with chloroform). The rise of resistance becomes faster with closely succeeding applications of potential. This is ascribed to the removal from the protoplasm of ions to which it is reversible. There is some evidence that these may be potassium ions. Much of the apparent resistance rise may be accounted for by a back E.M.F. caused by the flow of current. The Rockefeller University Press 1930-07-20 /pmc/articles/PMC2141080/ /pubmed/19872564 Text en Copyright © Copyright, 1930, by The Rockefeller Institute for Medical Research This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
Blinks, L. R.
THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA
title THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA
title_full THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA
title_fullStr THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA
title_full_unstemmed THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA
title_short THE VARIATION OF ELECTRICAL RESISTANCE WITH APPLIED POTENTIAL : I. INTACT VALONIA VENTRICOSA
title_sort variation of electrical resistance with applied potential : i. intact valonia ventricosa
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2141080/
https://www.ncbi.nlm.nih.gov/pubmed/19872564
work_keys_str_mv AT blinkslr thevariationofelectricalresistancewithappliedpotentialiintactvaloniaventricosa
AT blinkslr variationofelectricalresistancewithappliedpotentialiintactvaloniaventricosa