Cargando…

CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE

The bee's characteristic response to a movement of its visual field is used for the study of the relation between critical frequency of flicker and illumination. The critical flicker frequency varies with illumination in such a way that with increasing flicker frequency the intensity of illumin...

Descripción completa

Detalles Bibliográficos
Autor principal: Wolf, Ernst
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1933
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2141263/
https://www.ncbi.nlm.nih.gov/pubmed/19872764
_version_ 1782144173536706560
author Wolf, Ernst
author_facet Wolf, Ernst
author_sort Wolf, Ernst
collection PubMed
description The bee's characteristic response to a movement of its visual field is used for the study of the relation between critical frequency of flicker and illumination. The critical flicker frequency varies with illumination in such a way that with increasing flicker frequency the intensity of illumination must be increased to produce a threshold response in the bee. The illuminations required to give a response in a bee at different flicker frequencies closely correspond to the intensities for threshold response in visual acuity tests. This is due to the different thresholds of excitability of the elements of the ommatidial mosaic. An analysis of the variation of the values for threshold intensities at the several flicker frequencies shows that the variation depends upon flicker frequency and upon the number of elements functioning at different intensities.
format Text
id pubmed-2141263
institution National Center for Biotechnology Information
language English
publishDate 1933
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21412632008-04-23 CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE Wolf, Ernst J Gen Physiol Article The bee's characteristic response to a movement of its visual field is used for the study of the relation between critical frequency of flicker and illumination. The critical flicker frequency varies with illumination in such a way that with increasing flicker frequency the intensity of illumination must be increased to produce a threshold response in the bee. The illuminations required to give a response in a bee at different flicker frequencies closely correspond to the intensities for threshold response in visual acuity tests. This is due to the different thresholds of excitability of the elements of the ommatidial mosaic. An analysis of the variation of the values for threshold intensities at the several flicker frequencies shows that the variation depends upon flicker frequency and upon the number of elements functioning at different intensities. The Rockefeller University Press 1933-09-20 /pmc/articles/PMC2141263/ /pubmed/19872764 Text en Copyright © Copyright, 1933, by The Rockefeller Institute for Medical Research This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
Wolf, Ernst
CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE
title CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE
title_full CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE
title_fullStr CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE
title_full_unstemmed CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE
title_short CRITICAL FREQUENCY OF FLICKER AS A FUNCTION OF INTENSITY OF ILLUMINATION FOR THE EYE OF THE BEE
title_sort critical frequency of flicker as a function of intensity of illumination for the eye of the bee
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2141263/
https://www.ncbi.nlm.nih.gov/pubmed/19872764
work_keys_str_mv AT wolfernst criticalfrequencyofflickerasafunctionofintensityofilluminationfortheeyeofthebee