Cargando…

CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES

Flicker response curves have been obtained at 21.5°C. for three genera of fresh water teleosts: Enneacanthus (sunfish), Xiphophorus (swordtail), Platypoecilius (Platy), by the determination of mean critical intensities for response at fixed flicker frequencies, and for a certain homogeneous group of...

Descripción completa

Detalles Bibliográficos
Autores principales: Crozier, W. J., Wolf, E., Zerrahn-Wolf, Gertrud
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1937
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2141928/
https://www.ncbi.nlm.nih.gov/pubmed/19873037
_version_ 1782144257573781504
author Crozier, W. J.
Wolf, E.
Zerrahn-Wolf, Gertrud
author_facet Crozier, W. J.
Wolf, E.
Zerrahn-Wolf, Gertrud
author_sort Crozier, W. J.
collection PubMed
description Flicker response curves have been obtained at 21.5°C. for three genera of fresh water teleosts: Enneacanthus (sunfish), Xiphophorus (swordtail), Platypoecilius (Platy), by the determination of mean critical intensities for response at fixed flicker frequencies, and for a certain homogeneous group of backcross hybrids of swordtail x Platy (Black Helleri). The curves exhibit marked differences in form and proportions. The same type of analysis is applicable to each, however. A low intensity rod-governed section has added to it a more extensive cone portion. Each part is accurately described by the equation F = F(max.)/(1 + e (-p log(-p logI/I(i)))), where F = flicker frequency, I = associated mean critical intensity, and I(i) is the intensity at the inflection point of the sigmoid curve relating F to log I. There is no correlation between quantitative features of the rod and cone portions. Threshold intensities, p, I(i), and F(max.) are separately and independently determined. The hybrid Black Helleri show quantitative agreement with the Xiphophorus parental stock in the values of p for rods and cones, and in the cone F(max.); the rod F(max.) is very similar to that for the Platy stock; the general level of effective intensities is rather like that of the Platy form. This provides, among other things, a new kind of support for the duplicity doctrine. Various races of Platypoecilius maculatus, and P. variatus, give closely agreeing values of I(m) at different flicker frequencies; and two species of sunfish also agree. The effect of cross-breeding is thus not a superficial thing. It indicates the possibility of further genetic investigation. The variability of the critical intensity for response to flicker follows the rules previously found to hold for other forms. The variation is the expression of a property of the tested organism. It is shown that, on the assumption of a frequency distribution of receptor element thresholds as a function of log I, with fluctuation in the excitabilities of the marginally excited elements, it is to be expected that the dispersion of critical flicker frequencies in repeated measurements will pass through a maximum as log I is increased, whereas the dispersion of critical intensities will be proportional to I(m); and that the proportionality factor in the case of different organisms bears no relation to the form or position of the respective curves relating mean critical intensity to flicker frequency. These deductions agree with the experimental findings.
format Text
id pubmed-2141928
institution National Center for Biotechnology Information
language English
publishDate 1937
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21419282008-04-23 CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES Crozier, W. J. Wolf, E. Zerrahn-Wolf, Gertrud J Gen Physiol Article Flicker response curves have been obtained at 21.5°C. for three genera of fresh water teleosts: Enneacanthus (sunfish), Xiphophorus (swordtail), Platypoecilius (Platy), by the determination of mean critical intensities for response at fixed flicker frequencies, and for a certain homogeneous group of backcross hybrids of swordtail x Platy (Black Helleri). The curves exhibit marked differences in form and proportions. The same type of analysis is applicable to each, however. A low intensity rod-governed section has added to it a more extensive cone portion. Each part is accurately described by the equation F = F(max.)/(1 + e (-p log(-p logI/I(i)))), where F = flicker frequency, I = associated mean critical intensity, and I(i) is the intensity at the inflection point of the sigmoid curve relating F to log I. There is no correlation between quantitative features of the rod and cone portions. Threshold intensities, p, I(i), and F(max.) are separately and independently determined. The hybrid Black Helleri show quantitative agreement with the Xiphophorus parental stock in the values of p for rods and cones, and in the cone F(max.); the rod F(max.) is very similar to that for the Platy stock; the general level of effective intensities is rather like that of the Platy form. This provides, among other things, a new kind of support for the duplicity doctrine. Various races of Platypoecilius maculatus, and P. variatus, give closely agreeing values of I(m) at different flicker frequencies; and two species of sunfish also agree. The effect of cross-breeding is thus not a superficial thing. It indicates the possibility of further genetic investigation. The variability of the critical intensity for response to flicker follows the rules previously found to hold for other forms. The variation is the expression of a property of the tested organism. It is shown that, on the assumption of a frequency distribution of receptor element thresholds as a function of log I, with fluctuation in the excitabilities of the marginally excited elements, it is to be expected that the dispersion of critical flicker frequencies in repeated measurements will pass through a maximum as log I is increased, whereas the dispersion of critical intensities will be proportional to I(m); and that the proportionality factor in the case of different organisms bears no relation to the form or position of the respective curves relating mean critical intensity to flicker frequency. These deductions agree with the experimental findings. The Rockefeller University Press 1937-09-20 /pmc/articles/PMC2141928/ /pubmed/19873037 Text en Copyright © Copyright, 1937, by The Rockefeller Institute for Medical Research This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
Crozier, W. J.
Wolf, E.
Zerrahn-Wolf, Gertrud
CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES
title CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES
title_full CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES
title_fullStr CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES
title_full_unstemmed CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES
title_short CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES
title_sort critical illumination and flicker frequency in related fishes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2141928/
https://www.ncbi.nlm.nih.gov/pubmed/19873037
work_keys_str_mv AT crozierwj criticalilluminationandflickerfrequencyinrelatedfishes
AT wolfe criticalilluminationandflickerfrequencyinrelatedfishes
AT zerrahnwolfgertrud criticalilluminationandflickerfrequencyinrelatedfishes