Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients

BACKGROUND: The implantation of stentless valves is technically demanding and the outcome may depend on the performance of surgeons. We studied systematically the role of surgeons and other possible determinants for mid-term survival, postoperative gradients and Quality of Life (QoL) after aortic va...

Descripción completa

Detalles Bibliográficos
Autores principales: Albert, Alexander, Florath, Ines, Rosendahl, Ulrich, Hassanein, Wael, Hodenberg, Eberhard V, Bauer, Stefan, Ennker, Ina, Ennker, Jürgen
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2146998/
https://www.ncbi.nlm.nih.gov/pubmed/17919325
http://dx.doi.org/10.1186/1749-8090-2-40
_version_ 1782144339958300672
author Albert, Alexander
Florath, Ines
Rosendahl, Ulrich
Hassanein, Wael
Hodenberg, Eberhard V
Bauer, Stefan
Ennker, Ina
Ennker, Jürgen
author_facet Albert, Alexander
Florath, Ines
Rosendahl, Ulrich
Hassanein, Wael
Hodenberg, Eberhard V
Bauer, Stefan
Ennker, Ina
Ennker, Jürgen
author_sort Albert, Alexander
collection PubMed
description BACKGROUND: The implantation of stentless valves is technically demanding and the outcome may depend on the performance of surgeons. We studied systematically the role of surgeons and other possible determinants for mid-term survival, postoperative gradients and Quality of Life (QoL) after aortic valve replacement (AVR) with Freestyle(® )stentless bioprostheses. METHODS: Between 1996 and 2003, 587 patients (mean 75 years) underwent AVR with stentless Medtronic Freestyle(® )bioprostheses. Follow-up was 99% complete. Determinants of morbidity, mortality, survival time and QoL were evaluated by multiple, time-related, regression analysis. Risk models were built for all sections of the Nottingham Health Profile (NHP): energy, pain, emotional reaction, sleep, social isolation and physical mobility RESULTS: Actuarial freedom from aortic valve re-operation, structural valve deterioration, non-structural valve dysfunction, prosthetic valve endocarditis and thromboembolic events at 6 years were 95.9 ± 2.1%, 100%, 98.7 ± 0.5%, 97.0 ± 1.5%, 79.6 ± 4.3%, respectively. The actuarial freedom from bleeding events at 6 years was 93.1 ± 1.9%. Estimated survival at 6 years was similar to the age-matched German population (61.4 ± 3.8 %). Predictors of survival time were: diabetes mellitus, atrial fibrillation, peripheral vascular disease, renal dysfunction, female gender > 80 years and patients < 165 cm with BMI < 24. Predictive models showed characteristic profiles and good discriminative powers (c-indexes > 0.7) for each of the 6 QoL sections. Early transvalvular gradients were identified as independent risk factors for impaired physical mobility (c-index 0.77, p < 0.002). A saturated propensity score identified besides patient related factors (e.g. preoperative gradients, ejection fraction, haematological factors) indexed geometric orifice area, subcoronary implantation technique and individual surgeons as predictors of high gradients. CONCLUSION: In addition to the valve size (in relation to body size), subcoronary technique (versus total root) and various patient-related factors the risk of elevated gradients after stentless valve implantation depends, considerably on the individual surgeon. Although there was no effect on survival time and most aspects of QoL, higher postoperative transvalvular gradients affect physical mobility after AVR.
format Text
id pubmed-2146998
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-21469982007-12-19 Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients Albert, Alexander Florath, Ines Rosendahl, Ulrich Hassanein, Wael Hodenberg, Eberhard V Bauer, Stefan Ennker, Ina Ennker, Jürgen J Cardiothorac Surg Research Article BACKGROUND: The implantation of stentless valves is technically demanding and the outcome may depend on the performance of surgeons. We studied systematically the role of surgeons and other possible determinants for mid-term survival, postoperative gradients and Quality of Life (QoL) after aortic valve replacement (AVR) with Freestyle(® )stentless bioprostheses. METHODS: Between 1996 and 2003, 587 patients (mean 75 years) underwent AVR with stentless Medtronic Freestyle(® )bioprostheses. Follow-up was 99% complete. Determinants of morbidity, mortality, survival time and QoL were evaluated by multiple, time-related, regression analysis. Risk models were built for all sections of the Nottingham Health Profile (NHP): energy, pain, emotional reaction, sleep, social isolation and physical mobility RESULTS: Actuarial freedom from aortic valve re-operation, structural valve deterioration, non-structural valve dysfunction, prosthetic valve endocarditis and thromboembolic events at 6 years were 95.9 ± 2.1%, 100%, 98.7 ± 0.5%, 97.0 ± 1.5%, 79.6 ± 4.3%, respectively. The actuarial freedom from bleeding events at 6 years was 93.1 ± 1.9%. Estimated survival at 6 years was similar to the age-matched German population (61.4 ± 3.8 %). Predictors of survival time were: diabetes mellitus, atrial fibrillation, peripheral vascular disease, renal dysfunction, female gender > 80 years and patients < 165 cm with BMI < 24. Predictive models showed characteristic profiles and good discriminative powers (c-indexes > 0.7) for each of the 6 QoL sections. Early transvalvular gradients were identified as independent risk factors for impaired physical mobility (c-index 0.77, p < 0.002). A saturated propensity score identified besides patient related factors (e.g. preoperative gradients, ejection fraction, haematological factors) indexed geometric orifice area, subcoronary implantation technique and individual surgeons as predictors of high gradients. CONCLUSION: In addition to the valve size (in relation to body size), subcoronary technique (versus total root) and various patient-related factors the risk of elevated gradients after stentless valve implantation depends, considerably on the individual surgeon. Although there was no effect on survival time and most aspects of QoL, higher postoperative transvalvular gradients affect physical mobility after AVR. BioMed Central 2007-10-05 /pmc/articles/PMC2146998/ /pubmed/17919325 http://dx.doi.org/10.1186/1749-8090-2-40 Text en Copyright © 2007 Albert et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Albert, Alexander
Florath, Ines
Rosendahl, Ulrich
Hassanein, Wael
Hodenberg, Eberhard V
Bauer, Stefan
Ennker, Ina
Ennker, Jürgen
Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients
title Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients
title_full Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients
title_fullStr Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients
title_full_unstemmed Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients
title_short Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle(® )stentless bioprosthesis and its consequences: A follow-up study in 587 patients
title_sort effect of surgeon on transprosthetic gradients after aortic valve replacement with freestyle(® )stentless bioprosthesis and its consequences: a follow-up study in 587 patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2146998/
https://www.ncbi.nlm.nih.gov/pubmed/17919325
http://dx.doi.org/10.1186/1749-8090-2-40
work_keys_str_mv AT albertalexander effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients
AT florathines effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients
AT rosendahlulrich effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients
AT hassaneinwael effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients
AT hodenbergeberhardv effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients
AT bauerstefan effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients
AT ennkerina effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients
AT ennkerjurgen effectofsurgeonontransprostheticgradientsafteraorticvalvereplacementwithfreestylestentlessbioprosthesisanditsconsequencesafollowupstudyin587patients