Cargando…

Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order

Voltage clamp fluorometry (VCF) combines conventional two-electrode voltage clamp with fluorescence measurements to detect protein conformational changes, as sensed by a fluorophore covalently attached to the protein. We have applied VCF to a type IIb Na(+)-coupled phosphate cotransporter (NaPi-IIb)...

Descripción completa

Detalles Bibliográficos
Autores principales: Virkki, Leila V., Murer, Heini, Forster, Ian C.
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2151518/
https://www.ncbi.nlm.nih.gov/pubmed/16636203
http://dx.doi.org/10.1085/jgp.200609496
_version_ 1782144732724461568
author Virkki, Leila V.
Murer, Heini
Forster, Ian C.
author_facet Virkki, Leila V.
Murer, Heini
Forster, Ian C.
author_sort Virkki, Leila V.
collection PubMed
description Voltage clamp fluorometry (VCF) combines conventional two-electrode voltage clamp with fluorescence measurements to detect protein conformational changes, as sensed by a fluorophore covalently attached to the protein. We have applied VCF to a type IIb Na(+)-coupled phosphate cotransporter (NaPi-IIb), in which a novel cysteine was introduced in the putative third extracellular loop and expressed in Xenopus oocytes. Labeling this cysteine (S448C) with methanethiosulfonate (MTS) reagents blocked cotransport function, however previous electrophysiological studies (Lambert G., I.C. Forster, G. Stange, J. Biber, and H. Murer. 1999. J. Gen. Physiol. 114:637–651) suggest that substrate interactions with the protein can still occur, thus permitting study of a limited subset of states. After labeling S448C with the fluorophore tetramethylrhodamine MTS, we detected voltage- and substrate-dependent changes in fluorescence (ΔF), which suggested that this site lies in an environment that is affected by conformational change in the protein. ΔF was substrate dependent (no ΔF was detectable in 0 mM Na(+)) and showed little correlation with presteady-state charge movements, indicating that the two signals provide insight into different underlying physical processes. Interpretation of ion substitution experiments indicated that the substrate binding order differs from our previous model (Forster, I., N. Hernando, J. Biber, and H. Murer. 1998. J. Gen. Physiol. 112:1–18). In the new model, two (rather than one) Na(+) ions precede P(i) binding, and only the second Na(+) binding transition is voltage dependent. Moreover, we show that Li(+), which does not drive cotransport, interacts with the first Na(+) binding transition. The results were incorporated in a new model of the transport cycle of type II Na(+)/P(i) cotransporters, the validity of which is supported by simulations that successfully predict the voltage and substrate dependency of the experimentally determined fluorescence changes.
format Text
id pubmed-2151518
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-21515182008-01-17 Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order Virkki, Leila V. Murer, Heini Forster, Ian C. J Gen Physiol Articles Voltage clamp fluorometry (VCF) combines conventional two-electrode voltage clamp with fluorescence measurements to detect protein conformational changes, as sensed by a fluorophore covalently attached to the protein. We have applied VCF to a type IIb Na(+)-coupled phosphate cotransporter (NaPi-IIb), in which a novel cysteine was introduced in the putative third extracellular loop and expressed in Xenopus oocytes. Labeling this cysteine (S448C) with methanethiosulfonate (MTS) reagents blocked cotransport function, however previous electrophysiological studies (Lambert G., I.C. Forster, G. Stange, J. Biber, and H. Murer. 1999. J. Gen. Physiol. 114:637–651) suggest that substrate interactions with the protein can still occur, thus permitting study of a limited subset of states. After labeling S448C with the fluorophore tetramethylrhodamine MTS, we detected voltage- and substrate-dependent changes in fluorescence (ΔF), which suggested that this site lies in an environment that is affected by conformational change in the protein. ΔF was substrate dependent (no ΔF was detectable in 0 mM Na(+)) and showed little correlation with presteady-state charge movements, indicating that the two signals provide insight into different underlying physical processes. Interpretation of ion substitution experiments indicated that the substrate binding order differs from our previous model (Forster, I., N. Hernando, J. Biber, and H. Murer. 1998. J. Gen. Physiol. 112:1–18). In the new model, two (rather than one) Na(+) ions precede P(i) binding, and only the second Na(+) binding transition is voltage dependent. Moreover, we show that Li(+), which does not drive cotransport, interacts with the first Na(+) binding transition. The results were incorporated in a new model of the transport cycle of type II Na(+)/P(i) cotransporters, the validity of which is supported by simulations that successfully predict the voltage and substrate dependency of the experimentally determined fluorescence changes. The Rockefeller University Press 2006-05 /pmc/articles/PMC2151518/ /pubmed/16636203 http://dx.doi.org/10.1085/jgp.200609496 Text en Copyright © 2006, The Rockefeller University Press This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Articles
Virkki, Leila V.
Murer, Heini
Forster, Ian C.
Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order
title Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order
title_full Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order
title_fullStr Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order
title_full_unstemmed Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order
title_short Voltage Clamp Fluorometric Measurements on a Type II Na(+)-coupled P(i) Cotransporter: Shedding Light on Substrate Binding Order
title_sort voltage clamp fluorometric measurements on a type ii na(+)-coupled p(i) cotransporter: shedding light on substrate binding order
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2151518/
https://www.ncbi.nlm.nih.gov/pubmed/16636203
http://dx.doi.org/10.1085/jgp.200609496
work_keys_str_mv AT virkkileilav voltageclampfluorometricmeasurementsonatypeiinacoupledpicotransportersheddinglightonsubstratebindingorder
AT murerheini voltageclampfluorometricmeasurementsonatypeiinacoupledpicotransportersheddinglightonsubstratebindingorder
AT forsterianc voltageclampfluorometricmeasurementsonatypeiinacoupledpicotransportersheddinglightonsubstratebindingorder