Cargando…
QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS
The present study was designed to devise and characterize an indirect or sandwich radioimmunolabeling technique for the study of lymphocyte surface receptors of immunoglobulin nature. Mouse lymphocytes from various sources were treated by the method of Shortman et al. to remove debris and damaged ce...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1972
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2180525/ https://www.ncbi.nlm.nih.gov/pubmed/4110525 |
_version_ | 1782145566771249152 |
---|---|
author | Nossal, G. J. V. Warner, N. L. Lewis, Heather Sprent, J. |
author_facet | Nossal, G. J. V. Warner, N. L. Lewis, Heather Sprent, J. |
author_sort | Nossal, G. J. V. |
collection | PubMed |
description | The present study was designed to devise and characterize an indirect or sandwich radioimmunolabeling technique for the study of lymphocyte surface receptors of immunoglobulin nature. Mouse lymphocytes from various sources were treated by the method of Shortman et al. to remove debris and damaged cells. This was an important preliminary step, as without it, little meaning could be attached to bulk scintillation counting of labeled cell suspensions, in view of the marked tendency of dead or damaged cells to adsorb protein nonspecifically. Next, cells were reacted at 0°C for 30 min with graded dilutions of unlabeled rabbit antisera against defined mouse Ig chains. After washing, the cells were reacted with a sheep anti-rabbit globulin reagent labeled with (125)I, again at graded concentrations. After further washing, lymphocyte labeling was quantitated by both bulk scintillation counting and radioautography. Conditions were defined in which nonthymus-derived cells (B cells) but not thymus-derived cells (T cells) could be labeled. Most B cells displayed κ- and µ-chains on their surface, but some also displayed α- and γ(2)-chains, though in smaller amounts. When the concentration of both the first and the second reagents were raised considerably, conditions were defined under which virtually all T cells could be labeled by polyvalent antiglobulin sera, anti-κ sera, or, with more difficulty, by anti-µ sera. A large series of control experiments confirmed the serologic specificity of this labeling. It was shown that under equivalent conditions, B cells bind 100–400 times more antiglobulin than do T cells. The theoretical implications of the results are briefly discussed. It is argued that the sandwich approach offers certain technical advantages over direct labeling procedures for further analyses of T cell receptors and for studies of receptor metabolism. |
format | Text |
id | pubmed-2180525 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1972 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-21805252008-04-17 QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS Nossal, G. J. V. Warner, N. L. Lewis, Heather Sprent, J. J Exp Med Article The present study was designed to devise and characterize an indirect or sandwich radioimmunolabeling technique for the study of lymphocyte surface receptors of immunoglobulin nature. Mouse lymphocytes from various sources were treated by the method of Shortman et al. to remove debris and damaged cells. This was an important preliminary step, as without it, little meaning could be attached to bulk scintillation counting of labeled cell suspensions, in view of the marked tendency of dead or damaged cells to adsorb protein nonspecifically. Next, cells were reacted at 0°C for 30 min with graded dilutions of unlabeled rabbit antisera against defined mouse Ig chains. After washing, the cells were reacted with a sheep anti-rabbit globulin reagent labeled with (125)I, again at graded concentrations. After further washing, lymphocyte labeling was quantitated by both bulk scintillation counting and radioautography. Conditions were defined in which nonthymus-derived cells (B cells) but not thymus-derived cells (T cells) could be labeled. Most B cells displayed κ- and µ-chains on their surface, but some also displayed α- and γ(2)-chains, though in smaller amounts. When the concentration of both the first and the second reagents were raised considerably, conditions were defined under which virtually all T cells could be labeled by polyvalent antiglobulin sera, anti-κ sera, or, with more difficulty, by anti-µ sera. A large series of control experiments confirmed the serologic specificity of this labeling. It was shown that under equivalent conditions, B cells bind 100–400 times more antiglobulin than do T cells. The theoretical implications of the results are briefly discussed. It is argued that the sandwich approach offers certain technical advantages over direct labeling procedures for further analyses of T cell receptors and for studies of receptor metabolism. The Rockefeller University Press 1972-01-31 /pmc/articles/PMC2180525/ /pubmed/4110525 Text en Copyright © 1972 by The Rockefeller University Press This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/). |
spellingShingle | Article Nossal, G. J. V. Warner, N. L. Lewis, Heather Sprent, J. QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS |
title | QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS |
title_full | QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS |
title_fullStr | QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS |
title_full_unstemmed | QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS |
title_short | QUANTITATIVE FEATURES OF A SANDWICH RADIOIMMUNOLABELING TECHNIQUE FOR LYMPHOCYTE SURFACE RECEPTORS |
title_sort | quantitative features of a sandwich radioimmunolabeling technique for lymphocyte surface receptors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2180525/ https://www.ncbi.nlm.nih.gov/pubmed/4110525 |
work_keys_str_mv | AT nossalgjv quantitativefeaturesofasandwichradioimmunolabelingtechniqueforlymphocytesurfacereceptors AT warnernl quantitativefeaturesofasandwichradioimmunolabelingtechniqueforlymphocytesurfacereceptors AT lewisheather quantitativefeaturesofasandwichradioimmunolabelingtechniqueforlymphocytesurfacereceptors AT sprentj quantitativefeaturesofasandwichradioimmunolabelingtechniqueforlymphocytesurfacereceptors |