Cargando…
Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney
Transtubular and peritubular face electrical potential differences (P.D.) of the proximal tubules of the kidney of the amphibian Necturus maculosus have been measured in situ. These measurements have been carried out both under normal conditions, when the tubular fluid originates in the glomerular f...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1961
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2195121/ https://www.ncbi.nlm.nih.gov/pubmed/13784944 |
_version_ | 1782147771357200384 |
---|---|
author | Whittembury, Guillermo Windhager, Erich E. |
author_facet | Whittembury, Guillermo Windhager, Erich E. |
author_sort | Whittembury, Guillermo |
collection | PubMed |
description | Transtubular and peritubular face electrical potential differences (P.D.) of the proximal tubules of the kidney of the amphibian Necturus maculosus have been measured in situ. These measurements have been carried out both under normal conditions, when the tubular fluid originates in the glomerular filtrate, and under conditions when the composition of the tubular fluid has been altered using the stopped flow microperfusion technique. Under normal conditions the transtubular potential difference is 20 mv. (lumen-negative) and the P.D. across the peritubular face is 74 mv. (cell-negative). The P.D. across the luminal face is thus 54 mv. (cell-negative). This electrical asymmetry is not influenced by replacing the normal tubular fluid by NaCl, NaCl + mannitol, or by alteration in the intraluminal pH from 7 to 4. On the other hand, replacement of Na by K or choline and the addition of small amounts of DNP to the perfusate diminish this asymmetry. |
format | Text |
id | pubmed-2195121 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1961 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-21951212008-04-23 Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney Whittembury, Guillermo Windhager, Erich E. J Gen Physiol Article Transtubular and peritubular face electrical potential differences (P.D.) of the proximal tubules of the kidney of the amphibian Necturus maculosus have been measured in situ. These measurements have been carried out both under normal conditions, when the tubular fluid originates in the glomerular filtrate, and under conditions when the composition of the tubular fluid has been altered using the stopped flow microperfusion technique. Under normal conditions the transtubular potential difference is 20 mv. (lumen-negative) and the P.D. across the peritubular face is 74 mv. (cell-negative). The P.D. across the luminal face is thus 54 mv. (cell-negative). This electrical asymmetry is not influenced by replacing the normal tubular fluid by NaCl, NaCl + mannitol, or by alteration in the intraluminal pH from 7 to 4. On the other hand, replacement of Na by K or choline and the addition of small amounts of DNP to the perfusate diminish this asymmetry. The Rockefeller University Press 1961-03-01 /pmc/articles/PMC2195121/ /pubmed/13784944 Text en Copyright © Copyright, 1961, by The Rockefeller Institute This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/). |
spellingShingle | Article Whittembury, Guillermo Windhager, Erich E. Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney |
title | Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney |
title_full | Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney |
title_fullStr | Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney |
title_full_unstemmed | Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney |
title_short | Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus Kidney |
title_sort | electrical potential difference measurements in perfused single proximal tubules of necturus kidney |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2195121/ https://www.ncbi.nlm.nih.gov/pubmed/13784944 |
work_keys_str_mv | AT whittemburyguillermo electricalpotentialdifferencemeasurementsinperfusedsingleproximaltubulesofnecturuskidney AT windhagereriche electricalpotentialdifferencemeasurementsinperfusedsingleproximaltubulesofnecturuskidney |