Cargando…

A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants

BACKGROUND: The aim of this study was to evaluate bone mineral density (BMD) at baseline and at 18 and 36 months of use of etonogestrel (ENG)-and levonorgestrel (LNG)-releasing contraceptive implants. This is a continuation of a previous study in which BMD was evaluated at baseline and at 18 months...

Descripción completa

Detalles Bibliográficos
Autores principales: Monteiro-Dantas, Cecilia, Espejo-Arce, Ximena, Lui-Filho, Jeffrey F, Fernandes, Arlete M, Monteiro, Ilza, Bahamondes, Luis
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2200638/
https://www.ncbi.nlm.nih.gov/pubmed/17997844
http://dx.doi.org/10.1186/1742-4755-4-11
_version_ 1782148289818263552
author Monteiro-Dantas, Cecilia
Espejo-Arce, Ximena
Lui-Filho, Jeffrey F
Fernandes, Arlete M
Monteiro, Ilza
Bahamondes, Luis
author_facet Monteiro-Dantas, Cecilia
Espejo-Arce, Ximena
Lui-Filho, Jeffrey F
Fernandes, Arlete M
Monteiro, Ilza
Bahamondes, Luis
author_sort Monteiro-Dantas, Cecilia
collection PubMed
description BACKGROUND: The aim of this study was to evaluate bone mineral density (BMD) at baseline and at 18 and 36 months of use of etonogestrel (ENG)-and levonorgestrel (LNG)-releasing contraceptive implants. This is a continuation of a previous study in which BMD was evaluated at baseline and at 18 months of use. METHODS: A total of 111 women, 19–43 years of age, wererandomly allocated to use one of the two implants. At 36 months of follow-up, only 36 and 39 women were still using the ENG- and LNG-releasing implants, respectively. BMD was evaluated at the distal and at the ultra-distal radius of the non-dominant forearm using dual-energy X-ray absorptiometry. RESULTS: There was no difference in the BMD of users of either implant at 18 and at 36 months. BMD was significantly lower at 18 and at 36 months at the distal radius in both groups of users compared to pre-insertion values; however, no difference was found at the ultra-distal radius. CONCLUSION: Women 19–43 years of age using either one of these two contraceptive implants for 36 months had lower BMD values at the distal radius compared to pre-insertion values; however, no difference was found at the ultra-distal radius.
format Text
id pubmed-2200638
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-22006382008-01-16 A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants Monteiro-Dantas, Cecilia Espejo-Arce, Ximena Lui-Filho, Jeffrey F Fernandes, Arlete M Monteiro, Ilza Bahamondes, Luis Reprod Health Research BACKGROUND: The aim of this study was to evaluate bone mineral density (BMD) at baseline and at 18 and 36 months of use of etonogestrel (ENG)-and levonorgestrel (LNG)-releasing contraceptive implants. This is a continuation of a previous study in which BMD was evaluated at baseline and at 18 months of use. METHODS: A total of 111 women, 19–43 years of age, wererandomly allocated to use one of the two implants. At 36 months of follow-up, only 36 and 39 women were still using the ENG- and LNG-releasing implants, respectively. BMD was evaluated at the distal and at the ultra-distal radius of the non-dominant forearm using dual-energy X-ray absorptiometry. RESULTS: There was no difference in the BMD of users of either implant at 18 and at 36 months. BMD was significantly lower at 18 and at 36 months at the distal radius in both groups of users compared to pre-insertion values; however, no difference was found at the ultra-distal radius. CONCLUSION: Women 19–43 years of age using either one of these two contraceptive implants for 36 months had lower BMD values at the distal radius compared to pre-insertion values; however, no difference was found at the ultra-distal radius. BioMed Central 2007-11-12 /pmc/articles/PMC2200638/ /pubmed/17997844 http://dx.doi.org/10.1186/1742-4755-4-11 Text en Copyright © 2007 Monteiro-Dantas et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Monteiro-Dantas, Cecilia
Espejo-Arce, Ximena
Lui-Filho, Jeffrey F
Fernandes, Arlete M
Monteiro, Ilza
Bahamondes, Luis
A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants
title A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants
title_full A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants
title_fullStr A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants
title_full_unstemmed A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants
title_short A three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants
title_sort three-year longitudinal evaluation of the forearm bone density of users of etonogestrel- and levonorgestrel-releasing contraceptive implants
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2200638/
https://www.ncbi.nlm.nih.gov/pubmed/17997844
http://dx.doi.org/10.1186/1742-4755-4-11
work_keys_str_mv AT monteirodantascecilia athreeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT espejoarceximena athreeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT luifilhojeffreyf athreeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT fernandesarletem athreeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT monteiroilza athreeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT bahamondesluis athreeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT monteirodantascecilia threeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT espejoarceximena threeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT luifilhojeffreyf threeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT fernandesarletem threeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT monteiroilza threeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants
AT bahamondesluis threeyearlongitudinalevaluationoftheforearmbonedensityofusersofetonogestrelandlevonorgestrelreleasingcontraceptiveimplants