Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling
Extravascular signal decay rate R2 or R [Formula: see text] as a function of blood oxygenation, geometry, and field strength was calculated using a Monte Carlo (MC) algorithm for a wider parameter range than hitherto by others. The relaxation rates of gradient-recalled-echo (GRE) and Hahn-spin-echo...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2216119/ https://www.ncbi.nlm.nih.gov/pubmed/18273394 http://dx.doi.org/10.1155/2007/70309 |
_version_ | 1782149108975271936 |
---|---|
author | Mueller-Bierl, Bernd Michael Uludag, Kamil Pereira, Philippe L. Schick, Fritz |
author_facet | Mueller-Bierl, Bernd Michael Uludag, Kamil Pereira, Philippe L. Schick, Fritz |
author_sort | Mueller-Bierl, Bernd Michael |
collection | PubMed |
description | Extravascular signal decay rate R2 or R [Formula: see text] as a function of blood oxygenation, geometry, and field strength was calculated using a Monte Carlo (MC) algorithm for a wider parameter range than hitherto by others. The relaxation rates of gradient-recalled-echo (GRE) and Hahn-spin-echo (HSE) imaging in the presence of blood vessels (ranging from capillaries to veins) have been computed for a wide range of field strengths up to 9.4T and 50% blood deoxygenation. The maximum HSE decay was found to be shifted to lower radii in higher compared to lower field strengths. For GRE, however, the relaxation rate was greatest for large vessels at any field strength. In addition, assessments of computational reliability have been carried out by investigating the influence of the time step, the Monte Carlo step procedure, boundary conditions, the number of angles between the vessel and the exterior field [Formula: see text] , the influence of neighboring vessels having the same orientation as the central vessel, and the number of proton spins. The results were compared with those obtained from a field distribution of the vessel computed by an analytic formula describing the field distribution of an ideal object (an infinitely long cylinder). It was found that the time step is not critical for values equal to or lower than 200 microseconds. The choice of the MC step procedure (three-dimensional Gaussian diffusion, constant one- or three-dimensional diffusion step) also failed to influence the results significantly; in contrast, the free boundary conditions, as well as taking too few angles into account, did introduce errors. Next neighbor vessels with the same orientation as the main vessel did not contribute significantly to signal decay. The total number of particles simulated was also found to play a minor role in computing R2/ R [Formula: see text] . |
format | Text |
id | pubmed-2216119 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-22161192008-02-13 Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling Mueller-Bierl, Bernd Michael Uludag, Kamil Pereira, Philippe L. Schick, Fritz Int J Biomed Imaging Research Article Extravascular signal decay rate R2 or R [Formula: see text] as a function of blood oxygenation, geometry, and field strength was calculated using a Monte Carlo (MC) algorithm for a wider parameter range than hitherto by others. The relaxation rates of gradient-recalled-echo (GRE) and Hahn-spin-echo (HSE) imaging in the presence of blood vessels (ranging from capillaries to veins) have been computed for a wide range of field strengths up to 9.4T and 50% blood deoxygenation. The maximum HSE decay was found to be shifted to lower radii in higher compared to lower field strengths. For GRE, however, the relaxation rate was greatest for large vessels at any field strength. In addition, assessments of computational reliability have been carried out by investigating the influence of the time step, the Monte Carlo step procedure, boundary conditions, the number of angles between the vessel and the exterior field [Formula: see text] , the influence of neighboring vessels having the same orientation as the central vessel, and the number of proton spins. The results were compared with those obtained from a field distribution of the vessel computed by an analytic formula describing the field distribution of an ideal object (an infinitely long cylinder). It was found that the time step is not critical for values equal to or lower than 200 microseconds. The choice of the MC step procedure (three-dimensional Gaussian diffusion, constant one- or three-dimensional diffusion step) also failed to influence the results significantly; in contrast, the free boundary conditions, as well as taking too few angles into account, did introduce errors. Next neighbor vessels with the same orientation as the main vessel did not contribute significantly to signal decay. The total number of particles simulated was also found to play a minor role in computing R2/ R [Formula: see text] . Hindawi Publishing Corporation 2007 2007-10-02 /pmc/articles/PMC2216119/ /pubmed/18273394 http://dx.doi.org/10.1155/2007/70309 Text en Copyright © 2007 Bernd Michael Mueller-Bierl et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mueller-Bierl, Bernd Michael Uludag, Kamil Pereira, Philippe L. Schick, Fritz Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling |
title | Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling |
title_full | Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling |
title_fullStr | Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling |
title_full_unstemmed | Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling |
title_short | Magnetic Field Distribution and Signal Decay in Functional MRI in Very High Fields (up to 9.4 T) Using Monte Carlo Diffusion Modeling |
title_sort | magnetic field distribution and signal decay in functional mri in very high fields (up to 9.4 t) using monte carlo diffusion modeling |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2216119/ https://www.ncbi.nlm.nih.gov/pubmed/18273394 http://dx.doi.org/10.1155/2007/70309 |
work_keys_str_mv | AT muellerbierlberndmichael magneticfielddistributionandsignaldecayinfunctionalmriinveryhighfieldsupto94tusingmontecarlodiffusionmodeling AT uludagkamil magneticfielddistributionandsignaldecayinfunctionalmriinveryhighfieldsupto94tusingmontecarlodiffusionmodeling AT pereiraphilippel magneticfielddistributionandsignaldecayinfunctionalmriinveryhighfieldsupto94tusingmontecarlodiffusionmodeling AT schickfritz magneticfielddistributionandsignaldecayinfunctionalmriinveryhighfieldsupto94tusingmontecarlodiffusionmodeling |