Cargando…
Temperature dependence of ion permeation at the endplate channel
The dependence of acetylcholine receptor mean single-channel conductance on temperature was studied at garter snake twitch-muscle endplates using fluctuation analysis. In normal saline under conditions where most of the endplate current was carried by Na+, the channel conductance increased continuou...
Formato: | Texto |
---|---|
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1983
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2216562/ https://www.ncbi.nlm.nih.gov/pubmed/6306140 |
Ejemplares similares
-
Effects of ammonium ions on endplate channels
Publicado: (1980) -
Ion permeation in potassium ion channels
por: Coates, Leighton
Publicado: (2020) -
Current-dependent block of endplate channels by guanidine derivatives
Publicado: (1984) -
Temperature dependence of proton permeation through a voltage-gated proton channel
por: Kuno, Miyuki, et al.
Publicado: (2009) -
Deuterium oxide and temperature effects on the properties of endplate channels at the frog neuromuscular junction
Publicado: (1985)