REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE
Certain phenomena affecting contrast obtained from tissue sections with the electron microscope have been investigated and a technique is described for reducing destruction by the electron beam of fine details in sections. It has been concluded that loss of embedding material is slightly higher at e...
Autor principal: | |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1957
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2224129/ https://www.ncbi.nlm.nih.gov/pubmed/13481033 |
_version_ | 1782149497972850688 |
---|---|
author | Watson, Michael L. |
author_facet | Watson, Michael L. |
author_sort | Watson, Michael L. |
collection | PubMed |
description | Certain phenomena affecting contrast obtained from tissue sections with the electron microscope have been investigated and a technique is described for reducing destruction by the electron beam of fine details in sections. It has been concluded that loss of embedding material is slightly higher at exposed surfaces of sections than it is at surfaces covered by substrate film. Covering of both surfaces of sections with thin films of formvar, collodion, or carbon materially improves the general appearance, reduces distortion, and sometimes reduces loss of tissue mass from the section as result of exposure to the electron beam. This improvement is considered to result from the relatively high melting-point of the covering films which serve to eliminate or reduce surface-tension or other forces operating in methacrylate softened by the electron beam. |
format | Text |
id | pubmed-2224129 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1957 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-22241292008-05-01 REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE Watson, Michael L. J Biophys Biochem Cytol Article Certain phenomena affecting contrast obtained from tissue sections with the electron microscope have been investigated and a technique is described for reducing destruction by the electron beam of fine details in sections. It has been concluded that loss of embedding material is slightly higher at exposed surfaces of sections than it is at surfaces covered by substrate film. Covering of both surfaces of sections with thin films of formvar, collodion, or carbon materially improves the general appearance, reduces distortion, and sometimes reduces loss of tissue mass from the section as result of exposure to the electron beam. This improvement is considered to result from the relatively high melting-point of the covering films which serve to eliminate or reduce surface-tension or other forces operating in methacrylate softened by the electron beam. The Rockefeller University Press 1957-11-25 /pmc/articles/PMC2224129/ /pubmed/13481033 Text en Copyright © Copyright, 1957, by The Rockefeller Institute for Medical Research |
spellingShingle | Article Watson, Michael L. REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE |
title | REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE |
title_full | REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE |
title_fullStr | REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE |
title_full_unstemmed | REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE |
title_short | REDUCTION OF HEATING ARTIFACTS IN THIN SECTIONS EXAMINED IN THE ELECTRON MICROSCOPE |
title_sort | reduction of heating artifacts in thin sections examined in the electron microscope |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2224129/ https://www.ncbi.nlm.nih.gov/pubmed/13481033 |
work_keys_str_mv | AT watsonmichaell reductionofheatingartifactsinthinsectionsexaminedintheelectronmicroscope |