Cargando…
Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments
The equivalent circuit that has been used in the analysis of nerve voltage-clamp data is that of the membrane capacity in parallel with the membrane resistance. Voltage-clamp experiments on frog atrial tissue indicate that this circuit will not suffice for this cardiac tissue. The change in membrane...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
1971
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2226042/ https://www.ncbi.nlm.nih.gov/pubmed/5122371 |
_version_ | 1782149764842782720 |
---|---|
author | Tarr, Merrill Trank, John |
author_facet | Tarr, Merrill Trank, John |
author_sort | Tarr, Merrill |
collection | PubMed |
description | The equivalent circuit that has been used in the analysis of nerve voltage-clamp data is that of the membrane capacity in parallel with the membrane resistance. Voltage-clamp experiments on frog atrial tissue indicate that this circuit will not suffice for this cardiac tissue. The change in membrane current associated with a step change in membrane potential does not show a rapid spike of capacitive current as would be expected for the simple parallel resistance-capacitance network. Rather, there is a step change in current followed by an exponential decay in current with a time constant of about 1 msec. This relatively slow capacitive charging current suggests that there is a resistance in series with the membrane capacity. A possible equivalent circuit is that of a series resistance external to the parallel resistance-capacitance network of the cell membranes. Another possible circuit assumes that the series resistance is an integral part of the cell membrane. The data presented in this paper demonstrate that the equivalent circuit of a bundle of frog atrial muscle is that of an external resistance in series with the cell membranes. |
format | Text |
id | pubmed-2226042 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1971 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-22260422008-04-23 Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments Tarr, Merrill Trank, John J Gen Physiol Article The equivalent circuit that has been used in the analysis of nerve voltage-clamp data is that of the membrane capacity in parallel with the membrane resistance. Voltage-clamp experiments on frog atrial tissue indicate that this circuit will not suffice for this cardiac tissue. The change in membrane current associated with a step change in membrane potential does not show a rapid spike of capacitive current as would be expected for the simple parallel resistance-capacitance network. Rather, there is a step change in current followed by an exponential decay in current with a time constant of about 1 msec. This relatively slow capacitive charging current suggests that there is a resistance in series with the membrane capacity. A possible equivalent circuit is that of a series resistance external to the parallel resistance-capacitance network of the cell membranes. Another possible circuit assumes that the series resistance is an integral part of the cell membrane. The data presented in this paper demonstrate that the equivalent circuit of a bundle of frog atrial muscle is that of an external resistance in series with the cell membranes. The Rockefeller University Press 1971-11-01 /pmc/articles/PMC2226042/ /pubmed/5122371 Text en Copyright © 1971 by The Rockefeller University Press This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/). |
spellingShingle | Article Tarr, Merrill Trank, John Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments |
title | Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments |
title_full | Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments |
title_fullStr | Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments |
title_full_unstemmed | Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments |
title_short | Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments |
title_sort | equivalent circuit of frog atrial tissue as determined by voltage clamp-unclamp experiments |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2226042/ https://www.ncbi.nlm.nih.gov/pubmed/5122371 |
work_keys_str_mv | AT tarrmerrill equivalentcircuitoffrogatrialtissueasdeterminedbyvoltageclampunclampexperiments AT trankjohn equivalentcircuitoffrogatrialtissueasdeterminedbyvoltageclampunclampexperiments |