Cargando…

THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION

1. The foveal visual acuity of eleven subjects was studied in relation to illumination under normal atmospheric conditions and at simulated altitudes of 10,000 feet (14.3 per cent O(2)) and 18,000 feet (10.3 per cent O(2)). A mask was used to administer the desired mixtures of oxygen and nitrogen. A...

Descripción completa

Detalles Bibliográficos
Autores principales: McFarland, R. A., Halperin, M. H.
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1940
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2237947/
https://www.ncbi.nlm.nih.gov/pubmed/19873178
_version_ 1782150425889210368
author McFarland, R. A.
Halperin, M. H.
author_facet McFarland, R. A.
Halperin, M. H.
author_sort McFarland, R. A.
collection PubMed
description 1. The foveal visual acuity of eleven subjects was studied in relation to illumination under normal atmospheric conditions and at simulated altitudes of 10,000 feet (14.3 per cent O(2)) and 18,000 feet (10.3 per cent O(2)). A mask was used to administer the desired mixtures of oxygen and nitrogen. At the end of each experiment, measurements were made while inhaling 100 per cent oxygen from a cylinder. A red filter (No. 70 Wratten) was used so as to study only the behavior of the cones of the retina. 2. The logarithm of illumination was plotted horizontally (abscissa) and the logarithm of visual acuity vertically (ordinate). The reduced oxygen tensions resulted in a shift of the curve to the right, along the intensity axis, the extent of the change being 0.24 of a log unit at 14.3 per cent O(2) and 0.47 of a log unit at 10.3 per cent O(2). These effects were completely counteracted within a few minutes by inhaling oxygen. 3. As a consequence of the shape of the curve, such a shift to the right resulted in a relatively large decrease of visual acuity at low illuminations. At increasing light intensities anoxia produced less and less change, until at very high illuminations the decrease was negligible. Thus with 10.34 per cent O(2) the visual acuity at 0.144 photons decreased an average of 0.344 of a log unit, to 45 per cent of its normal value. At 1320 photons, however, it decreased only 0.026 of a log unit, to 94 per cent of its normal value for that intensity.
format Text
id pubmed-2237947
institution National Center for Biotechnology Information
language English
publishDate 1940
publisher The Rockefeller University Press
record_format MEDLINE/PubMed
spelling pubmed-22379472008-04-23 THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION McFarland, R. A. Halperin, M. H. J Gen Physiol Article 1. The foveal visual acuity of eleven subjects was studied in relation to illumination under normal atmospheric conditions and at simulated altitudes of 10,000 feet (14.3 per cent O(2)) and 18,000 feet (10.3 per cent O(2)). A mask was used to administer the desired mixtures of oxygen and nitrogen. At the end of each experiment, measurements were made while inhaling 100 per cent oxygen from a cylinder. A red filter (No. 70 Wratten) was used so as to study only the behavior of the cones of the retina. 2. The logarithm of illumination was plotted horizontally (abscissa) and the logarithm of visual acuity vertically (ordinate). The reduced oxygen tensions resulted in a shift of the curve to the right, along the intensity axis, the extent of the change being 0.24 of a log unit at 14.3 per cent O(2) and 0.47 of a log unit at 10.3 per cent O(2). These effects were completely counteracted within a few minutes by inhaling oxygen. 3. As a consequence of the shape of the curve, such a shift to the right resulted in a relatively large decrease of visual acuity at low illuminations. At increasing light intensities anoxia produced less and less change, until at very high illuminations the decrease was negligible. Thus with 10.34 per cent O(2) the visual acuity at 0.144 photons decreased an average of 0.344 of a log unit, to 45 per cent of its normal value. At 1320 photons, however, it decreased only 0.026 of a log unit, to 94 per cent of its normal value for that intensity. The Rockefeller University Press 1940-05-20 /pmc/articles/PMC2237947/ /pubmed/19873178 Text en Copyright © Copyright, 1940, The Rockefeller Institute for Medical Research This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 4.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Article
McFarland, R. A.
Halperin, M. H.
THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION
title THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION
title_full THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION
title_fullStr THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION
title_full_unstemmed THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION
title_short THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION
title_sort relation between foveal visual acuity and illumination under reduced oxygen tension
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2237947/
https://www.ncbi.nlm.nih.gov/pubmed/19873178
work_keys_str_mv AT mcfarlandra therelationbetweenfovealvisualacuityandilluminationunderreducedoxygentension
AT halperinmh therelationbetweenfovealvisualacuityandilluminationunderreducedoxygentension
AT mcfarlandra relationbetweenfovealvisualacuityandilluminationunderreducedoxygentension
AT halperinmh relationbetweenfovealvisualacuityandilluminationunderreducedoxygentension