A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions

INTRODUCTION: Characterizing and differentiating between malignant tumors, benign tumors, and normal breast tissue is increasingly important in the patient presenting with breast problems. Near-infrared diffuse optical imaging and spectroscopy is capable of measuring multiple physiologic parameters...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Ronald X, Young, Donn C, Mao, Jimmy J, Povoski, Stephen P
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2246191/
https://www.ncbi.nlm.nih.gov/pubmed/18088411
http://dx.doi.org/10.1186/bcr1837
_version_ 1782150736726982656
author Xu, Ronald X
Young, Donn C
Mao, Jimmy J
Povoski, Stephen P
author_facet Xu, Ronald X
Young, Donn C
Mao, Jimmy J
Povoski, Stephen P
author_sort Xu, Ronald X
collection PubMed
description INTRODUCTION: Characterizing and differentiating between malignant tumors, benign tumors, and normal breast tissue is increasingly important in the patient presenting with breast problems. Near-infrared diffuse optical imaging and spectroscopy is capable of measuring multiple physiologic parameters of biological tissue systems and may have clinical applications for assessing the development and progression of neoplastic processes, including breast cancer. The currently available application of near-infrared imaging technology for the breast, however, is compromised by low spatial resolution, tissue heterogeneity, and interpatient variation. MATERIALS AND METHODS: We tested a dynamic near-infrared imaging schema for the characterization of suspicious breast lesions identified on diagnostic clinical ultrasound. A portable handheld near-infrared tissue imaging device (P-Scan; ViOptix Inc., Fremont, CA, USA) was utilized. An external mechanical compression force was applied to breast tissue. The tissue oxygen saturation and hemoglobin concentration were recorded simultaneously by the handheld near-infrared imaging device. Twelve categories of dynamic tissue parameters were derived based on real-time measurements of the tissue hemoglobin concentration and the oxygen saturation. RESULTS: Fifty suspicious breast lesions were evaluated in 48 patients. Statistical analyses were carried out on 36 out of 50 datasets that satisfied our inclusion criteria. Suspicious breast lesions identified on diagnostic clinical ultrasound had lower oxygenation and higher hemoglobin concentration than the surrounding normal breast tissue. Furthermore, histopathologic-proven malignant breast tumors had a lower differential hemoglobin contrast (that is, the difference of hemoglobin concentration variability between the suspicious breast lesion and the normal breast parenchyma located remotely elsewhere within the ipsilateral breast) as compared with histopathologic-proven benign breast lesions. CONCLUSION: The proposed dynamic near-infrared imaging schema has the potential to differentiate benign processes from those of malignant breast tumors. Further development and refinement of the dynamic imaging device and additional subsequent clinical testing are necessary for optimizing the accuracy of detection.
format Text
id pubmed-2246191
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-22461912008-06-04 A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions Xu, Ronald X Young, Donn C Mao, Jimmy J Povoski, Stephen P Breast Cancer Res Research Article INTRODUCTION: Characterizing and differentiating between malignant tumors, benign tumors, and normal breast tissue is increasingly important in the patient presenting with breast problems. Near-infrared diffuse optical imaging and spectroscopy is capable of measuring multiple physiologic parameters of biological tissue systems and may have clinical applications for assessing the development and progression of neoplastic processes, including breast cancer. The currently available application of near-infrared imaging technology for the breast, however, is compromised by low spatial resolution, tissue heterogeneity, and interpatient variation. MATERIALS AND METHODS: We tested a dynamic near-infrared imaging schema for the characterization of suspicious breast lesions identified on diagnostic clinical ultrasound. A portable handheld near-infrared tissue imaging device (P-Scan; ViOptix Inc., Fremont, CA, USA) was utilized. An external mechanical compression force was applied to breast tissue. The tissue oxygen saturation and hemoglobin concentration were recorded simultaneously by the handheld near-infrared imaging device. Twelve categories of dynamic tissue parameters were derived based on real-time measurements of the tissue hemoglobin concentration and the oxygen saturation. RESULTS: Fifty suspicious breast lesions were evaluated in 48 patients. Statistical analyses were carried out on 36 out of 50 datasets that satisfied our inclusion criteria. Suspicious breast lesions identified on diagnostic clinical ultrasound had lower oxygenation and higher hemoglobin concentration than the surrounding normal breast tissue. Furthermore, histopathologic-proven malignant breast tumors had a lower differential hemoglobin contrast (that is, the difference of hemoglobin concentration variability between the suspicious breast lesion and the normal breast parenchyma located remotely elsewhere within the ipsilateral breast) as compared with histopathologic-proven benign breast lesions. CONCLUSION: The proposed dynamic near-infrared imaging schema has the potential to differentiate benign processes from those of malignant breast tumors. Further development and refinement of the dynamic imaging device and additional subsequent clinical testing are necessary for optimizing the accuracy of detection. BioMed Central 2007 2007-12-18 /pmc/articles/PMC2246191/ /pubmed/18088411 http://dx.doi.org/10.1186/bcr1837 Text en Copyright © 2008 Xu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Xu, Ronald X
Young, Donn C
Mao, Jimmy J
Povoski, Stephen P
A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
title A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
title_full A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
title_fullStr A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
title_full_unstemmed A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
title_short A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
title_sort prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2246191/
https://www.ncbi.nlm.nih.gov/pubmed/18088411
http://dx.doi.org/10.1186/bcr1837
work_keys_str_mv AT xuronaldx aprospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions
AT youngdonnc aprospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions
AT maojimmyj aprospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions
AT povoskistephenp aprospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions
AT xuronaldx prospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions
AT youngdonnc prospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions
AT maojimmyj prospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions
AT povoskistephenp prospectivepilotclinicaltrialevaluatingtheutilityofadynamicnearinfraredimagingdeviceforcharacterizingsuspiciousbreastlesions