Cargando…

Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance

INTRODUCTION: Previous studies have shown through theoretical analyses that the ratio of the partial pressure of oxygen in arterial blood (PaO(2)) to the inspired oxygen fraction (FiO(2)) varies with the FiO(2 )level. The aim of the present study was to evaluate the relevance of this variation both...

Descripción completa

Detalles Bibliográficos
Autores principales: Karbing, Dan S, Kjærgaard, Søren, Smith, Bram W, Espersen, Kurt, Allerød, Charlotte, Andreassen, Steen, Rees, Stephen E
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2246207/
https://www.ncbi.nlm.nih.gov/pubmed/17988390
http://dx.doi.org/10.1186/cc6174
_version_ 1782150740482981888
author Karbing, Dan S
Kjærgaard, Søren
Smith, Bram W
Espersen, Kurt
Allerød, Charlotte
Andreassen, Steen
Rees, Stephen E
author_facet Karbing, Dan S
Kjærgaard, Søren
Smith, Bram W
Espersen, Kurt
Allerød, Charlotte
Andreassen, Steen
Rees, Stephen E
author_sort Karbing, Dan S
collection PubMed
description INTRODUCTION: Previous studies have shown through theoretical analyses that the ratio of the partial pressure of oxygen in arterial blood (PaO(2)) to the inspired oxygen fraction (FiO(2)) varies with the FiO(2 )level. The aim of the present study was to evaluate the relevance of this variation both theoretically and experimentally using mathematical model simulations, comparing these ratio simulations with PaO(2)/FiO(2 )ratios measured in a range of different patients. METHODS: The study was designed as a retrospective study using data from 36 mechanically ventilated patients and 57 spontaneously breathing patients studied on one or more occasions. Patients were classified into four disease groups (normal, mild hypoxemia, acute lung injury and acute respiratory distress syndrome) according to their PaO(2)/FiO(2 )ratio. On each occasion the patients were studied using four to eight different FiO(2 )values, achieving arterial oxygen saturations in the range 85–100%. At each FiO(2 )level, measurements were taken of ventilation, of arterial acid–base and of oxygenation status. Two mathematical models were fitted to the data: a one-parameter 'effective shunt' model, and a two-parameter shunt and ventilation/perfusion model. These models and patient data were used to investigate the variation in the PaO(2)/FiO(2 )ratio with FiO(2), and to quantify how many patients changed disease classification due to variation in the PaO(2)/FiO(2 )ratio. An F test was used to assess the statistical difference between the two models' fit to the data. A confusion matrix was used to quantify the number of patients changing disease classification. RESULTS: The two-parameter model gave a statistically better fit to patient data (P < 0.005). When using this model to simulate variation in the PaO(2)/FiO(2 )ratio, disease classification changed in 30% of the patients when changing the FiO(2 )level. CONCLUSION: The PaO(2)/FiO(2 )ratio depends on both the FiO(2 )level and the arterial oxygen saturation level. As a minimum, the FiO(2 )level at which the PaO(2)/FiO(2 )ratio is measured should be defined when quantifying the effects of therapeutic interventions or when specifying diagnostic criteria for acute lung injury and acute respiratory distress syndrome. Alternatively, oxygenation problems could be described using parameters describing shunt and ventilation/perfusion mismatch.
format Text
id pubmed-2246207
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-22462072008-02-20 Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance Karbing, Dan S Kjærgaard, Søren Smith, Bram W Espersen, Kurt Allerød, Charlotte Andreassen, Steen Rees, Stephen E Crit Care Research INTRODUCTION: Previous studies have shown through theoretical analyses that the ratio of the partial pressure of oxygen in arterial blood (PaO(2)) to the inspired oxygen fraction (FiO(2)) varies with the FiO(2 )level. The aim of the present study was to evaluate the relevance of this variation both theoretically and experimentally using mathematical model simulations, comparing these ratio simulations with PaO(2)/FiO(2 )ratios measured in a range of different patients. METHODS: The study was designed as a retrospective study using data from 36 mechanically ventilated patients and 57 spontaneously breathing patients studied on one or more occasions. Patients were classified into four disease groups (normal, mild hypoxemia, acute lung injury and acute respiratory distress syndrome) according to their PaO(2)/FiO(2 )ratio. On each occasion the patients were studied using four to eight different FiO(2 )values, achieving arterial oxygen saturations in the range 85–100%. At each FiO(2 )level, measurements were taken of ventilation, of arterial acid–base and of oxygenation status. Two mathematical models were fitted to the data: a one-parameter 'effective shunt' model, and a two-parameter shunt and ventilation/perfusion model. These models and patient data were used to investigate the variation in the PaO(2)/FiO(2 )ratio with FiO(2), and to quantify how many patients changed disease classification due to variation in the PaO(2)/FiO(2 )ratio. An F test was used to assess the statistical difference between the two models' fit to the data. A confusion matrix was used to quantify the number of patients changing disease classification. RESULTS: The two-parameter model gave a statistically better fit to patient data (P < 0.005). When using this model to simulate variation in the PaO(2)/FiO(2 )ratio, disease classification changed in 30% of the patients when changing the FiO(2 )level. CONCLUSION: The PaO(2)/FiO(2 )ratio depends on both the FiO(2 )level and the arterial oxygen saturation level. As a minimum, the FiO(2 )level at which the PaO(2)/FiO(2 )ratio is measured should be defined when quantifying the effects of therapeutic interventions or when specifying diagnostic criteria for acute lung injury and acute respiratory distress syndrome. Alternatively, oxygenation problems could be described using parameters describing shunt and ventilation/perfusion mismatch. BioMed Central 2007 2007-11-07 /pmc/articles/PMC2246207/ /pubmed/17988390 http://dx.doi.org/10.1186/cc6174 Text en Copyright © 2007 Karbing et al., licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Karbing, Dan S
Kjærgaard, Søren
Smith, Bram W
Espersen, Kurt
Allerød, Charlotte
Andreassen, Steen
Rees, Stephen E
Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance
title Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance
title_full Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance
title_fullStr Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance
title_full_unstemmed Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance
title_short Variation in the PaO(2)/FiO(2 )ratio with FiO(2): mathematical and experimental description, and clinical relevance
title_sort variation in the pao(2)/fio(2 )ratio with fio(2): mathematical and experimental description, and clinical relevance
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2246207/
https://www.ncbi.nlm.nih.gov/pubmed/17988390
http://dx.doi.org/10.1186/cc6174
work_keys_str_mv AT karbingdans variationinthepao2fio2ratiowithfio2mathematicalandexperimentaldescriptionandclinicalrelevance
AT kjærgaardsøren variationinthepao2fio2ratiowithfio2mathematicalandexperimentaldescriptionandclinicalrelevance
AT smithbramw variationinthepao2fio2ratiowithfio2mathematicalandexperimentaldescriptionandclinicalrelevance
AT espersenkurt variationinthepao2fio2ratiowithfio2mathematicalandexperimentaldescriptionandclinicalrelevance
AT allerødcharlotte variationinthepao2fio2ratiowithfio2mathematicalandexperimentaldescriptionandclinicalrelevance
AT andreassensteen variationinthepao2fio2ratiowithfio2mathematicalandexperimentaldescriptionandclinicalrelevance
AT reesstephene variationinthepao2fio2ratiowithfio2mathematicalandexperimentaldescriptionandclinicalrelevance