Ultrasound settings significantly alter arterial lumen and wall thickness measurements

BACKGROUND: Flow-mediated dilation (FMD) and carotid intima-medial thickness (CIMT), measured by ultrasound, are widely used to test the efficacy of cardioprotective interventions. Although assessment methods vary, automated edge-detecting image analysis software is routinely used to measure changes...

Descripción completa

Detalles Bibliográficos
Autores principales: Potter, Kathleen, Reed, Christopher J, Green, Daniel J, Hankey, Graeme J, Arnolda, Leonard F
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2254584/
https://www.ncbi.nlm.nih.gov/pubmed/18208623
http://dx.doi.org/10.1186/1476-7120-6-6
_version_ 1782151198568087552
author Potter, Kathleen
Reed, Christopher J
Green, Daniel J
Hankey, Graeme J
Arnolda, Leonard F
author_facet Potter, Kathleen
Reed, Christopher J
Green, Daniel J
Hankey, Graeme J
Arnolda, Leonard F
author_sort Potter, Kathleen
collection PubMed
description BACKGROUND: Flow-mediated dilation (FMD) and carotid intima-medial thickness (CIMT), measured by ultrasound, are widely used to test the efficacy of cardioprotective interventions. Although assessment methods vary, automated edge-detecting image analysis software is routinely used to measure changes in FMD and CIMT. We aimed to quantify the effect that commonly adjusted ultrasound settings have on arterial lumen and wall thickness measurements made with CIMT measurement software. METHODS: We constructed phantom arteries from a tissue-mimicking agar compound and scanned them in a water bath with a 10 MHz multi-frequency linear-array probe attached to a high-resolution ultrasound machine. B-mode images of the phantoms were recorded with dynamic range (DR) and gain set at five decibel (dB) increments from 40 dB to 60 dB and -10 dB to +10 dB respectively. Lumen diameter and wall-thickness were measured off-line using CIMT measurement software. RESULTS: Lumen measurements: there was a strong linear relationship between DR and gain and measured lumen diameter. For a given gain level, a 5 dB increase in DR reduced the measured lumen diameter by 0.02 ± 0.004 mm (p < 0.001). For a given DR level, a 5 dB increase in gain reduced measured lumen diameter by 0.04 ± 0.004 mm (p < 0.001). A 5 mm increase in distance between the ultrasound probe and the artery reduced measured lumen diameter by 0.04 ± 0.03 mm (p < 0.001) CIMT measurements: For a fixed gain level, a 5 dB increase in DR increased measured wall thickness by 0.003 ± 0.002 mm (p < 0.001). The effects of increasing gain were not consistent and appeared to vary depending on the distance between the artery and the ultrasound probe and the thickness of the artery wall. CONCLUSION: DR, gain and probe distance significantly alter lumen diameter and CIMT measurements made using image analysis software. When CIMT and FMD are used to test the efficacy of cardioprotective interventions, the DR, gain and probe position used to record baseline scans should be documented and replicated in post-treatment scans in individual trial subjects. If more than one sonographer or imaging centre is used to collect data, the study protocol should document specific DR and gain settings to be used in all subjects.
format Text
id pubmed-2254584
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-22545842008-02-27 Ultrasound settings significantly alter arterial lumen and wall thickness measurements Potter, Kathleen Reed, Christopher J Green, Daniel J Hankey, Graeme J Arnolda, Leonard F Cardiovasc Ultrasound Research BACKGROUND: Flow-mediated dilation (FMD) and carotid intima-medial thickness (CIMT), measured by ultrasound, are widely used to test the efficacy of cardioprotective interventions. Although assessment methods vary, automated edge-detecting image analysis software is routinely used to measure changes in FMD and CIMT. We aimed to quantify the effect that commonly adjusted ultrasound settings have on arterial lumen and wall thickness measurements made with CIMT measurement software. METHODS: We constructed phantom arteries from a tissue-mimicking agar compound and scanned them in a water bath with a 10 MHz multi-frequency linear-array probe attached to a high-resolution ultrasound machine. B-mode images of the phantoms were recorded with dynamic range (DR) and gain set at five decibel (dB) increments from 40 dB to 60 dB and -10 dB to +10 dB respectively. Lumen diameter and wall-thickness were measured off-line using CIMT measurement software. RESULTS: Lumen measurements: there was a strong linear relationship between DR and gain and measured lumen diameter. For a given gain level, a 5 dB increase in DR reduced the measured lumen diameter by 0.02 ± 0.004 mm (p < 0.001). For a given DR level, a 5 dB increase in gain reduced measured lumen diameter by 0.04 ± 0.004 mm (p < 0.001). A 5 mm increase in distance between the ultrasound probe and the artery reduced measured lumen diameter by 0.04 ± 0.03 mm (p < 0.001) CIMT measurements: For a fixed gain level, a 5 dB increase in DR increased measured wall thickness by 0.003 ± 0.002 mm (p < 0.001). The effects of increasing gain were not consistent and appeared to vary depending on the distance between the artery and the ultrasound probe and the thickness of the artery wall. CONCLUSION: DR, gain and probe distance significantly alter lumen diameter and CIMT measurements made using image analysis software. When CIMT and FMD are used to test the efficacy of cardioprotective interventions, the DR, gain and probe position used to record baseline scans should be documented and replicated in post-treatment scans in individual trial subjects. If more than one sonographer or imaging centre is used to collect data, the study protocol should document specific DR and gain settings to be used in all subjects. BioMed Central 2008-01-22 /pmc/articles/PMC2254584/ /pubmed/18208623 http://dx.doi.org/10.1186/1476-7120-6-6 Text en Copyright © 2008 Potter et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Potter, Kathleen
Reed, Christopher J
Green, Daniel J
Hankey, Graeme J
Arnolda, Leonard F
Ultrasound settings significantly alter arterial lumen and wall thickness measurements
title Ultrasound settings significantly alter arterial lumen and wall thickness measurements
title_full Ultrasound settings significantly alter arterial lumen and wall thickness measurements
title_fullStr Ultrasound settings significantly alter arterial lumen and wall thickness measurements
title_full_unstemmed Ultrasound settings significantly alter arterial lumen and wall thickness measurements
title_short Ultrasound settings significantly alter arterial lumen and wall thickness measurements
title_sort ultrasound settings significantly alter arterial lumen and wall thickness measurements
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2254584/
https://www.ncbi.nlm.nih.gov/pubmed/18208623
http://dx.doi.org/10.1186/1476-7120-6-6
work_keys_str_mv AT potterkathleen ultrasoundsettingssignificantlyalterarteriallumenandwallthicknessmeasurements
AT reedchristopherj ultrasoundsettingssignificantlyalterarteriallumenandwallthicknessmeasurements
AT greendanielj ultrasoundsettingssignificantlyalterarteriallumenandwallthicknessmeasurements
AT hankeygraemej ultrasoundsettingssignificantlyalterarteriallumenandwallthicknessmeasurements
AT arnoldaleonardf ultrasoundsettingssignificantlyalterarteriallumenandwallthicknessmeasurements