Cargando…

Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol

BACKGROUND: Much of the experimental work in soft tissue mechanics has been focused on fitting approximate relations for specific tissue types from aggregate data on multiple samples of the tissue. Such relations are needed for modeling applications and have reasonable predictability – especially gi...

Descripción completa

Detalles Bibliográficos
Autores principales: Jhun, Choon-Sik, Criscione, John C
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2259303/
https://www.ncbi.nlm.nih.gov/pubmed/18211719
http://dx.doi.org/10.1186/1475-925X-7-4
_version_ 1782151368581054464
author Jhun, Choon-Sik
Criscione, John C
author_facet Jhun, Choon-Sik
Criscione, John C
author_sort Jhun, Choon-Sik
collection PubMed
description BACKGROUND: Much of the experimental work in soft tissue mechanics has been focused on fitting approximate relations for specific tissue types from aggregate data on multiple samples of the tissue. Such relations are needed for modeling applications and have reasonable predictability – especially given the natural variance in specimens. There is, however, much theoretical and experimental work to be done in determining constitutive behaviors for particular specimens and tissues. In so doing, it may be possible to exploit the natural variation in tissue ultrastructure – so to relate ultrastructure composition to tissue behavior. Thus, this study focuses on an experimental method for determining constitutive behaviors and illustrates the method with analysis of a porcine pulmonary artery strip. The method characterizes the elastic part of the response (implicitly in terms of stretch) and the inelastic part in terms of short term stretch history (i.e., stretch-rate) H(t2), longer term stretch history H(t1), and time since the start of testing T. METHODS: A uniaxial testing protocol with a random stretch and random stretch-rate was developed. The average stress at a particular stretch was chosen as the hyperelastic stress response, and deviation from the mean at this particular stretch is chosen as the inelastic deviation. Multivariable Linear Regression Analysis (MLRA) was utilized to verify if H(t2), H(t1), and T are important factors for characterizing the inelastic deviation. For acquiring H(t2 )and H(t1), an integral function type of stretch history was employed with time constants chosen from the relaxation spectrum of an identical size strip from the same tissue with the same orientation. Finally, statistical models that characterize the inelasticity were developed at various, nominal values of stretch, and their predictive capability was examined. RESULTS: Inelastic deviation from hyperelasticity was high (31%) for low stretch and declined significantly with increasing stretch to a nadir of 3.6% for a stretch of 1.7. The inelastic deviation then increased with increasing stretch at the same point in the stress-strain curve where stiffness began to increase strikingly. MLRA showed that T is a major inelastic parameter at low deformation. For moderate and high deformations, H(t2 )and H(t1 )were dominant. DISCUSSION: A randomized uniaxial testing protocol was applied to a strip of porcine pulmonary artery to characterize the elasticity and inelasticity of a soft tissue. We were successful in determining the elastic response and the factors that gave rise to the inelastic deviation. This investigation seeks methods to better define, phenomenologically, the elastic and inelastic behavior of soft tissues.
format Text
id pubmed-2259303
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-22593032008-03-13 Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol Jhun, Choon-Sik Criscione, John C Biomed Eng Online Research BACKGROUND: Much of the experimental work in soft tissue mechanics has been focused on fitting approximate relations for specific tissue types from aggregate data on multiple samples of the tissue. Such relations are needed for modeling applications and have reasonable predictability – especially given the natural variance in specimens. There is, however, much theoretical and experimental work to be done in determining constitutive behaviors for particular specimens and tissues. In so doing, it may be possible to exploit the natural variation in tissue ultrastructure – so to relate ultrastructure composition to tissue behavior. Thus, this study focuses on an experimental method for determining constitutive behaviors and illustrates the method with analysis of a porcine pulmonary artery strip. The method characterizes the elastic part of the response (implicitly in terms of stretch) and the inelastic part in terms of short term stretch history (i.e., stretch-rate) H(t2), longer term stretch history H(t1), and time since the start of testing T. METHODS: A uniaxial testing protocol with a random stretch and random stretch-rate was developed. The average stress at a particular stretch was chosen as the hyperelastic stress response, and deviation from the mean at this particular stretch is chosen as the inelastic deviation. Multivariable Linear Regression Analysis (MLRA) was utilized to verify if H(t2), H(t1), and T are important factors for characterizing the inelastic deviation. For acquiring H(t2 )and H(t1), an integral function type of stretch history was employed with time constants chosen from the relaxation spectrum of an identical size strip from the same tissue with the same orientation. Finally, statistical models that characterize the inelasticity were developed at various, nominal values of stretch, and their predictive capability was examined. RESULTS: Inelastic deviation from hyperelasticity was high (31%) for low stretch and declined significantly with increasing stretch to a nadir of 3.6% for a stretch of 1.7. The inelastic deviation then increased with increasing stretch at the same point in the stress-strain curve where stiffness began to increase strikingly. MLRA showed that T is a major inelastic parameter at low deformation. For moderate and high deformations, H(t2 )and H(t1 )were dominant. DISCUSSION: A randomized uniaxial testing protocol was applied to a strip of porcine pulmonary artery to characterize the elasticity and inelasticity of a soft tissue. We were successful in determining the elastic response and the factors that gave rise to the inelastic deviation. This investigation seeks methods to better define, phenomenologically, the elastic and inelastic behavior of soft tissues. BioMed Central 2008-01-23 /pmc/articles/PMC2259303/ /pubmed/18211719 http://dx.doi.org/10.1186/1475-925X-7-4 Text en Copyright © 2008 Jhun and Criscione; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Jhun, Choon-Sik
Criscione, John C
Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
title Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
title_full Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
title_fullStr Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
title_full_unstemmed Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
title_short Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
title_sort characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2259303/
https://www.ncbi.nlm.nih.gov/pubmed/18211719
http://dx.doi.org/10.1186/1475-925X-7-4
work_keys_str_mv AT jhunchoonsik characterizationofmechanicalbehaviorofaporcinepulmonaryarterystripusingarandomizeduniaxialstretchandstretchrateprotocol
AT criscionejohnc characterizationofmechanicalbehaviorofaporcinepulmonaryarterystripusingarandomizeduniaxialstretchandstretchrateprotocol