Cargando…
The reliability of knee joint position testing using electrogoniometry
BACKGROUND: The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric(® )electrogoniometer. The clinical utility of electrogoniometry was also addressed. METHODS: The first study examined the inter- and intr...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2263037/ https://www.ncbi.nlm.nih.gov/pubmed/18211714 http://dx.doi.org/10.1186/1471-2474-9-6 |
_version_ | 1782151433420800000 |
---|---|
author | Piriyaprasarth, Pagamas Morris, Meg E Winter, Adele Bialocerkowski, Andrea E |
author_facet | Piriyaprasarth, Pagamas Morris, Meg E Winter, Adele Bialocerkowski, Andrea E |
author_sort | Piriyaprasarth, Pagamas |
collection | PubMed |
description | BACKGROUND: The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric(® )electrogoniometer. The clinical utility of electrogoniometry was also addressed. METHODS: The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. RESULTS: In the first study, inter-tester reliability (ICC([2,10])) ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC([3,10])) ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. CONCLUSION: Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer. |
format | Text |
id | pubmed-2263037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-22630372008-03-06 The reliability of knee joint position testing using electrogoniometry Piriyaprasarth, Pagamas Morris, Meg E Winter, Adele Bialocerkowski, Andrea E BMC Musculoskelet Disord Research Article BACKGROUND: The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric(® )electrogoniometer. The clinical utility of electrogoniometry was also addressed. METHODS: The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. RESULTS: In the first study, inter-tester reliability (ICC([2,10])) ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC([3,10])) ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. CONCLUSION: Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer. BioMed Central 2008-01-22 /pmc/articles/PMC2263037/ /pubmed/18211714 http://dx.doi.org/10.1186/1471-2474-9-6 Text en Copyright © 2008 Piriyaprasarth et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Piriyaprasarth, Pagamas Morris, Meg E Winter, Adele Bialocerkowski, Andrea E The reliability of knee joint position testing using electrogoniometry |
title | The reliability of knee joint position testing using electrogoniometry |
title_full | The reliability of knee joint position testing using electrogoniometry |
title_fullStr | The reliability of knee joint position testing using electrogoniometry |
title_full_unstemmed | The reliability of knee joint position testing using electrogoniometry |
title_short | The reliability of knee joint position testing using electrogoniometry |
title_sort | reliability of knee joint position testing using electrogoniometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2263037/ https://www.ncbi.nlm.nih.gov/pubmed/18211714 http://dx.doi.org/10.1186/1471-2474-9-6 |
work_keys_str_mv | AT piriyaprasarthpagamas thereliabilityofkneejointpositiontestingusingelectrogoniometry AT morrismege thereliabilityofkneejointpositiontestingusingelectrogoniometry AT winteradele thereliabilityofkneejointpositiontestingusingelectrogoniometry AT bialocerkowskiandreae thereliabilityofkneejointpositiontestingusingelectrogoniometry AT piriyaprasarthpagamas reliabilityofkneejointpositiontestingusingelectrogoniometry AT morrismege reliabilityofkneejointpositiontestingusingelectrogoniometry AT winteradele reliabilityofkneejointpositiontestingusingelectrogoniometry AT bialocerkowskiandreae reliabilityofkneejointpositiontestingusingelectrogoniometry |