Cargando…

The reliability of knee joint position testing using electrogoniometry

BACKGROUND: The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric(® )electrogoniometer. The clinical utility of electrogoniometry was also addressed. METHODS: The first study examined the inter- and intr...

Descripción completa

Detalles Bibliográficos
Autores principales: Piriyaprasarth, Pagamas, Morris, Meg E, Winter, Adele, Bialocerkowski, Andrea E
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2263037/
https://www.ncbi.nlm.nih.gov/pubmed/18211714
http://dx.doi.org/10.1186/1471-2474-9-6
_version_ 1782151433420800000
author Piriyaprasarth, Pagamas
Morris, Meg E
Winter, Adele
Bialocerkowski, Andrea E
author_facet Piriyaprasarth, Pagamas
Morris, Meg E
Winter, Adele
Bialocerkowski, Andrea E
author_sort Piriyaprasarth, Pagamas
collection PubMed
description BACKGROUND: The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric(® )electrogoniometer. The clinical utility of electrogoniometry was also addressed. METHODS: The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. RESULTS: In the first study, inter-tester reliability (ICC([2,10])) ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC([3,10])) ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. CONCLUSION: Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.
format Text
id pubmed-2263037
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-22630372008-03-06 The reliability of knee joint position testing using electrogoniometry Piriyaprasarth, Pagamas Morris, Meg E Winter, Adele Bialocerkowski, Andrea E BMC Musculoskelet Disord Research Article BACKGROUND: The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric(® )electrogoniometer. The clinical utility of electrogoniometry was also addressed. METHODS: The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. RESULTS: In the first study, inter-tester reliability (ICC([2,10])) ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC([3,10])) ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. CONCLUSION: Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer. BioMed Central 2008-01-22 /pmc/articles/PMC2263037/ /pubmed/18211714 http://dx.doi.org/10.1186/1471-2474-9-6 Text en Copyright © 2008 Piriyaprasarth et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Piriyaprasarth, Pagamas
Morris, Meg E
Winter, Adele
Bialocerkowski, Andrea E
The reliability of knee joint position testing using electrogoniometry
title The reliability of knee joint position testing using electrogoniometry
title_full The reliability of knee joint position testing using electrogoniometry
title_fullStr The reliability of knee joint position testing using electrogoniometry
title_full_unstemmed The reliability of knee joint position testing using electrogoniometry
title_short The reliability of knee joint position testing using electrogoniometry
title_sort reliability of knee joint position testing using electrogoniometry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2263037/
https://www.ncbi.nlm.nih.gov/pubmed/18211714
http://dx.doi.org/10.1186/1471-2474-9-6
work_keys_str_mv AT piriyaprasarthpagamas thereliabilityofkneejointpositiontestingusingelectrogoniometry
AT morrismege thereliabilityofkneejointpositiontestingusingelectrogoniometry
AT winteradele thereliabilityofkneejointpositiontestingusingelectrogoniometry
AT bialocerkowskiandreae thereliabilityofkneejointpositiontestingusingelectrogoniometry
AT piriyaprasarthpagamas reliabilityofkneejointpositiontestingusingelectrogoniometry
AT morrismege reliabilityofkneejointpositiontestingusingelectrogoniometry
AT winteradele reliabilityofkneejointpositiontestingusingelectrogoniometry
AT bialocerkowskiandreae reliabilityofkneejointpositiontestingusingelectrogoniometry