Cargando…

Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis

We propose a novel framework to reduce background electroencephalogram (EEG) artifacts from multitrial visual-evoked potentials (VEPs) signals for use in brain-computer interface (BCI) design. An algorithm based on cyclostationary (CS) analysis is introduced to locate the suitable frequency ranges t...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Cota Navin, Palaniappan, Ramaswamy
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2266790/
https://www.ncbi.nlm.nih.gov/pubmed/18354722
http://dx.doi.org/10.1155/2007/28692
_version_ 1782151562382016512
author Gupta, Cota Navin
Palaniappan, Ramaswamy
author_facet Gupta, Cota Navin
Palaniappan, Ramaswamy
author_sort Gupta, Cota Navin
collection PubMed
description We propose a novel framework to reduce background electroencephalogram (EEG) artifacts from multitrial visual-evoked potentials (VEPs) signals for use in brain-computer interface (BCI) design. An algorithm based on cyclostationary (CS) analysis is introduced to locate the suitable frequency ranges that contain the stimulus-related VEP components. CS technique does not require VEP recordings to be phase locked and exploits the intertrial similarities of the VEP components in the frequency domain. The obtained cyclic frequency spectrum enables detection of VEP frequency band. Next, bandpass or lowpass filtering is performed to reduce the EEG artifacts using these identified frequency ranges. This is followed by overlapping band EEG artifact reduction using genetic algorithm and independent component analysis (G-ICA) which uses mutual information (MI) criterion to separate EEG artifacts from VEP. The CS and GA methods need to be applied only to the training data; for the test data, the knowledge of the cyclic frequency bands and unmixing matrix would be sufficient for enhanced VEP detection. Hence, the framework could be used for online VEP detection. This framework was tested with various datasets and it showed satisfactory results with very few trials. Since the framework is general, it could be applied to the enhancement of evoked potential signals for any application.
format Text
id pubmed-2266790
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-22667902008-03-19 Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis Gupta, Cota Navin Palaniappan, Ramaswamy Comput Intell Neurosci Research Article We propose a novel framework to reduce background electroencephalogram (EEG) artifacts from multitrial visual-evoked potentials (VEPs) signals for use in brain-computer interface (BCI) design. An algorithm based on cyclostationary (CS) analysis is introduced to locate the suitable frequency ranges that contain the stimulus-related VEP components. CS technique does not require VEP recordings to be phase locked and exploits the intertrial similarities of the VEP components in the frequency domain. The obtained cyclic frequency spectrum enables detection of VEP frequency band. Next, bandpass or lowpass filtering is performed to reduce the EEG artifacts using these identified frequency ranges. This is followed by overlapping band EEG artifact reduction using genetic algorithm and independent component analysis (G-ICA) which uses mutual information (MI) criterion to separate EEG artifacts from VEP. The CS and GA methods need to be applied only to the training data; for the test data, the knowledge of the cyclic frequency bands and unmixing matrix would be sufficient for enhanced VEP detection. Hence, the framework could be used for online VEP detection. This framework was tested with various datasets and it showed satisfactory results with very few trials. Since the framework is general, it could be applied to the enhancement of evoked potential signals for any application. Hindawi Publishing Corporation 2007 2007-09-11 /pmc/articles/PMC2266790/ /pubmed/18354722 http://dx.doi.org/10.1155/2007/28692 Text en Copyright © 2007 C. N. Gupta and R. Palaniappan. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Gupta, Cota Navin
Palaniappan, Ramaswamy
Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis
title Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis
title_full Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis
title_fullStr Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis
title_full_unstemmed Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis
title_short Enhanced Detection of Visual-Evoked Potentials in Brain-Computer Interface Using Genetic Algorithm and Cyclostationary Analysis
title_sort enhanced detection of visual-evoked potentials in brain-computer interface using genetic algorithm and cyclostationary analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2266790/
https://www.ncbi.nlm.nih.gov/pubmed/18354722
http://dx.doi.org/10.1155/2007/28692
work_keys_str_mv AT guptacotanavin enhanceddetectionofvisualevokedpotentialsinbraincomputerinterfaceusinggeneticalgorithmandcyclostationaryanalysis
AT palaniappanramaswamy enhanceddetectionofvisualevokedpotentialsinbraincomputerinterfaceusinggeneticalgorithmandcyclostationaryanalysis