Cargando…
Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis
Spectroscopic optical coherence tomography (spectroscopic OCT) is an echographic-like optical method for biomedical functional imaging. Current spectroscopic optical coherence tomography (OCT) methods rely on a posteriori numerical calculation. We present an alternative for optically accessing the s...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2276868/ https://www.ncbi.nlm.nih.gov/pubmed/18385813 http://dx.doi.org/10.1155/2008/752340 |
_version_ | 1782152013162741760 |
---|---|
author | Froehly, L. Ouadour, M. Furfaro, L. Sandoz, P. Leproux, P. Huss, G. Couderc, V. |
author_facet | Froehly, L. Ouadour, M. Furfaro, L. Sandoz, P. Leproux, P. Huss, G. Couderc, V. |
author_sort | Froehly, L. |
collection | PubMed |
description | Spectroscopic optical coherence tomography (spectroscopic OCT) is an echographic-like optical method for biomedical functional imaging. Current spectroscopic optical coherence tomography (OCT) methods rely on a posteriori numerical calculation. We present an alternative for optically accessing the spectroscopic information in OCT, that is, without postprocessing, by using a grating-based correlation and a wavelength demultiplexing system. Spectrally resolved A-scan is directly recorded on the image sensor. Due to the grating-based system, no correlation scan is necessary. The signal is registered in the wavelength-depth plane on a 2D camera that provides a large number of resolved points. In the frame of this paper, we present the principle of the system as well as demonstration results. Advantages and drawback of this system compared to others are discussed. |
format | Text |
id | pubmed-2276868 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-22768682008-04-02 Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis Froehly, L. Ouadour, M. Furfaro, L. Sandoz, P. Leproux, P. Huss, G. Couderc, V. Int J Biomed Imaging Research Article Spectroscopic optical coherence tomography (spectroscopic OCT) is an echographic-like optical method for biomedical functional imaging. Current spectroscopic optical coherence tomography (OCT) methods rely on a posteriori numerical calculation. We present an alternative for optically accessing the spectroscopic information in OCT, that is, without postprocessing, by using a grating-based correlation and a wavelength demultiplexing system. Spectrally resolved A-scan is directly recorded on the image sensor. Due to the grating-based system, no correlation scan is necessary. The signal is registered in the wavelength-depth plane on a 2D camera that provides a large number of resolved points. In the frame of this paper, we present the principle of the system as well as demonstration results. Advantages and drawback of this system compared to others are discussed. Hindawi Publishing Corporation 2008 2008-03-13 /pmc/articles/PMC2276868/ /pubmed/18385813 http://dx.doi.org/10.1155/2008/752340 Text en Copyright © 2008 L. Froehly et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Froehly, L. Ouadour, M. Furfaro, L. Sandoz, P. Leproux, P. Huss, G. Couderc, V. Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis |
title | Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis |
title_full | Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis |
title_fullStr | Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis |
title_full_unstemmed | Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis |
title_short | Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis |
title_sort | spectroscopic oct by grating-based temporal correlation coupled to optical spectral analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2276868/ https://www.ncbi.nlm.nih.gov/pubmed/18385813 http://dx.doi.org/10.1155/2008/752340 |
work_keys_str_mv | AT froehlyl spectroscopicoctbygratingbasedtemporalcorrelationcoupledtoopticalspectralanalysis AT ouadourm spectroscopicoctbygratingbasedtemporalcorrelationcoupledtoopticalspectralanalysis AT furfarol spectroscopicoctbygratingbasedtemporalcorrelationcoupledtoopticalspectralanalysis AT sandozp spectroscopicoctbygratingbasedtemporalcorrelationcoupledtoopticalspectralanalysis AT leprouxp spectroscopicoctbygratingbasedtemporalcorrelationcoupledtoopticalspectralanalysis AT hussg spectroscopicoctbygratingbasedtemporalcorrelationcoupledtoopticalspectralanalysis AT coudercv spectroscopicoctbygratingbasedtemporalcorrelationcoupledtoopticalspectralanalysis |