Cargando…

Human-machine interfaces based on EMG and EEG applied to robotic systems

BACKGROUND: Two different Human-Machine Interfaces (HMIs) were developed, both based on electro-biological signals. One is based on the EMG signal and the other is based on the EEG signal. Two major features of such interfaces are their relatively simple data acquisition and processing systems, whic...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferreira, Andre, Celeste, Wanderley C, Cheein, Fernando A, Bastos-Filho, Teodiano F, Sarcinelli-Filho, Mario, Carelli, Ricardo
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2292737/
https://www.ncbi.nlm.nih.gov/pubmed/18366775
http://dx.doi.org/10.1186/1743-0003-5-10
_version_ 1782152522445619200
author Ferreira, Andre
Celeste, Wanderley C
Cheein, Fernando A
Bastos-Filho, Teodiano F
Sarcinelli-Filho, Mario
Carelli, Ricardo
author_facet Ferreira, Andre
Celeste, Wanderley C
Cheein, Fernando A
Bastos-Filho, Teodiano F
Sarcinelli-Filho, Mario
Carelli, Ricardo
author_sort Ferreira, Andre
collection PubMed
description BACKGROUND: Two different Human-Machine Interfaces (HMIs) were developed, both based on electro-biological signals. One is based on the EMG signal and the other is based on the EEG signal. Two major features of such interfaces are their relatively simple data acquisition and processing systems, which need just a few hardware and software resources, so that they are, computationally and financially speaking, low cost solutions. Both interfaces were applied to robotic systems, and their performances are analyzed here. The EMG-based HMI was tested in a mobile robot, while the EEG-based HMI was tested in a mobile robot and a robotic manipulator as well. RESULTS: Experiments using the EMG-based HMI were carried out by eight individuals, who were asked to accomplish ten eye blinks with each eye, in order to test the eye blink detection algorithm. An average rightness rate of about 95% reached by individuals with the ability to blink both eyes allowed to conclude that the system could be used to command devices. Experiments with EEG consisted of inviting 25 people (some of them had suffered cases of meningitis and epilepsy) to test the system. All of them managed to deal with the HMI in only one training session. Most of them learnt how to use such HMI in less than 15 minutes. The minimum and maximum training times observed were 3 and 50 minutes, respectively. CONCLUSION: Such works are the initial parts of a system to help people with neuromotor diseases, including those with severe dysfunctions. The next steps are to convert a commercial wheelchair in an autonomous mobile vehicle; to implement the HMI onboard the autonomous wheelchair thus obtained to assist people with motor diseases, and to explore the potentiality of EEG signals, making the EEG-based HMI more robust and faster, aiming at using it to help individuals with severe motor dysfunctions.
format Text
id pubmed-2292737
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-22927372008-04-12 Human-machine interfaces based on EMG and EEG applied to robotic systems Ferreira, Andre Celeste, Wanderley C Cheein, Fernando A Bastos-Filho, Teodiano F Sarcinelli-Filho, Mario Carelli, Ricardo J Neuroeng Rehabil Research BACKGROUND: Two different Human-Machine Interfaces (HMIs) were developed, both based on electro-biological signals. One is based on the EMG signal and the other is based on the EEG signal. Two major features of such interfaces are their relatively simple data acquisition and processing systems, which need just a few hardware and software resources, so that they are, computationally and financially speaking, low cost solutions. Both interfaces were applied to robotic systems, and their performances are analyzed here. The EMG-based HMI was tested in a mobile robot, while the EEG-based HMI was tested in a mobile robot and a robotic manipulator as well. RESULTS: Experiments using the EMG-based HMI were carried out by eight individuals, who were asked to accomplish ten eye blinks with each eye, in order to test the eye blink detection algorithm. An average rightness rate of about 95% reached by individuals with the ability to blink both eyes allowed to conclude that the system could be used to command devices. Experiments with EEG consisted of inviting 25 people (some of them had suffered cases of meningitis and epilepsy) to test the system. All of them managed to deal with the HMI in only one training session. Most of them learnt how to use such HMI in less than 15 minutes. The minimum and maximum training times observed were 3 and 50 minutes, respectively. CONCLUSION: Such works are the initial parts of a system to help people with neuromotor diseases, including those with severe dysfunctions. The next steps are to convert a commercial wheelchair in an autonomous mobile vehicle; to implement the HMI onboard the autonomous wheelchair thus obtained to assist people with motor diseases, and to explore the potentiality of EEG signals, making the EEG-based HMI more robust and faster, aiming at using it to help individuals with severe motor dysfunctions. BioMed Central 2008-03-26 /pmc/articles/PMC2292737/ /pubmed/18366775 http://dx.doi.org/10.1186/1743-0003-5-10 Text en Copyright © 2008 Ferreira et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Ferreira, Andre
Celeste, Wanderley C
Cheein, Fernando A
Bastos-Filho, Teodiano F
Sarcinelli-Filho, Mario
Carelli, Ricardo
Human-machine interfaces based on EMG and EEG applied to robotic systems
title Human-machine interfaces based on EMG and EEG applied to robotic systems
title_full Human-machine interfaces based on EMG and EEG applied to robotic systems
title_fullStr Human-machine interfaces based on EMG and EEG applied to robotic systems
title_full_unstemmed Human-machine interfaces based on EMG and EEG applied to robotic systems
title_short Human-machine interfaces based on EMG and EEG applied to robotic systems
title_sort human-machine interfaces based on emg and eeg applied to robotic systems
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2292737/
https://www.ncbi.nlm.nih.gov/pubmed/18366775
http://dx.doi.org/10.1186/1743-0003-5-10
work_keys_str_mv AT ferreiraandre humanmachineinterfacesbasedonemgandeegappliedtoroboticsystems
AT celestewanderleyc humanmachineinterfacesbasedonemgandeegappliedtoroboticsystems
AT cheeinfernandoa humanmachineinterfacesbasedonemgandeegappliedtoroboticsystems
AT bastosfilhoteodianof humanmachineinterfacesbasedonemgandeegappliedtoroboticsystems
AT sarcinellifilhomario humanmachineinterfacesbasedonemgandeegappliedtoroboticsystems
AT carelliricardo humanmachineinterfacesbasedonemgandeegappliedtoroboticsystems