The first case report of dental floss pick-related injury presenting with massive hemoptysis: A case report
INTRODUCTION: A tracheobronchial foreign body is a rarely mentioned cause of massive hemoptysis. Although an aspirated toothpick is a well-known cause of traumatic injury to the respiratory tract, a similar device called a dental floss pick, which is much larger than a toothpick, has never been desc...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2294139/ https://www.ncbi.nlm.nih.gov/pubmed/18334020 http://dx.doi.org/10.1186/1752-1947-2-78 |
Sumario: | INTRODUCTION: A tracheobronchial foreign body is a rarely mentioned cause of massive hemoptysis. Although an aspirated toothpick is a well-known cause of traumatic injury to the respiratory tract, a similar device called a dental floss pick, which is much larger than a toothpick, has never been described as a tracheobronchial foreign body. CASE PRESENTATION: We report a case of massive hemoptysis in a 32-year-old man due to a dental floss pick in the left main bronchus. Flexible fiberoptic bronchoscopy was successful in removing the foreign body. CONCLUSION: Tracheobronchial foreign body can be a medical emergency requiring immediate intervention and massive hemoptysis may be the presenting symptom. Flexible fiberoptic bronchoscopy is recommended as the first-line treatment modality for tracheobronchial foreign body removal. A dental floss pick may present as a tracheobronchial foreign body and can reside in the airway asymptomatically for many years. |
---|