An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images
We have developed an algorithm for the rigid-body registration of a CT volume to a set of C-arm images. The algorithm uses a gradient-based iterative minimization of a least-squares measure of dissimilarity between the C-arm images and projections of the CT volume. To compute projections, we use a n...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2006
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2324037/ https://www.ncbi.nlm.nih.gov/pubmed/23165033 http://dx.doi.org/10.1155/IJBI/2006/47197 |
_version_ | 1782152705249116160 |
---|---|
author | Jonić, S. Thévenaz, P. Zheng, G. Nolte, L. -P. Unser, M. |
author_facet | Jonić, S. Thévenaz, P. Zheng, G. Nolte, L. -P. Unser, M. |
author_sort | Jonić, S. |
collection | PubMed |
description | We have developed an algorithm for the rigid-body registration of a CT volume to a set of C-arm images. The algorithm uses a gradient-based iterative minimization of a least-squares measure of dissimilarity between the C-arm images and projections of the CT volume. To compute projections, we use a novel method for fast integration of the volume along rays. To improve robustness and speed, we take advantage of a coarse-to-fine processing of the volume/image pyramids. To compute the projections of the volume, the gradient of the dissimilarity measure, and the multiresolution data pyramids, we use a continuous image/volume model based on cubic B-splines, which ensures a high interpolation accuracy and a gradient of the dissimilarity measure that is well defined everywhere. We show the performance of our algorithm on a human spine phantom, where the true alignment is determined using a set of fiducial markers. |
format | Text |
id | pubmed-2324037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2006 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-23240372008-04-22 An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images Jonić, S. Thévenaz, P. Zheng, G. Nolte, L. -P. Unser, M. Int J Biomed Imaging Article We have developed an algorithm for the rigid-body registration of a CT volume to a set of C-arm images. The algorithm uses a gradient-based iterative minimization of a least-squares measure of dissimilarity between the C-arm images and projections of the CT volume. To compute projections, we use a novel method for fast integration of the volume along rays. To improve robustness and speed, we take advantage of a coarse-to-fine processing of the volume/image pyramids. To compute the projections of the volume, the gradient of the dissimilarity measure, and the multiresolution data pyramids, we use a continuous image/volume model based on cubic B-splines, which ensures a high interpolation accuracy and a gradient of the dissimilarity measure that is well defined everywhere. We show the performance of our algorithm on a human spine phantom, where the true alignment is determined using a set of fiducial markers. Hindawi Publishing Corporation 2006 2006-04-06 /pmc/articles/PMC2324037/ /pubmed/23165033 http://dx.doi.org/10.1155/IJBI/2006/47197 Text en Copyright © 2006 S. Jonić et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Article Jonić, S. Thévenaz, P. Zheng, G. Nolte, L. -P. Unser, M. An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images |
title | An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images |
title_full | An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images |
title_fullStr | An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images |
title_full_unstemmed | An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images |
title_short | An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images |
title_sort | optimized spline-based registration of a 3d ct to a set of c-arm images |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2324037/ https://www.ncbi.nlm.nih.gov/pubmed/23165033 http://dx.doi.org/10.1155/IJBI/2006/47197 |
work_keys_str_mv | AT jonics anoptimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT thevenazp anoptimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT zhengg anoptimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT noltelp anoptimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT unserm anoptimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT jonics optimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT thevenazp optimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT zhengg optimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT noltelp optimizedsplinebasedregistrationofa3dcttoasetofcarmimages AT unserm optimizedsplinebasedregistrationofa3dcttoasetofcarmimages |