Cargando…

Partial Volume Reduction by Interpolation with Reverse Diffusion

Many medical images suffer from the partial volume effect where a boundary between two structures of interest falls in the midst of a voxel giving a signal value that is a mixture of the two. We propose a method to restore the ideal boundary by splitting a voxel into subvoxels and reapportioning the...

Descripción completa

Detalles Bibliográficos
Autores principales: Salvado, Olivier, Hillenbrand, Claudia M., Wilson, David L.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2324046/
https://www.ncbi.nlm.nih.gov/pubmed/23165058
http://dx.doi.org/10.1155/IJBI/2006/92092
_version_ 1782152707369336832
author Salvado, Olivier
Hillenbrand, Claudia M.
Wilson, David L.
author_facet Salvado, Olivier
Hillenbrand, Claudia M.
Wilson, David L.
author_sort Salvado, Olivier
collection PubMed
description Many medical images suffer from the partial volume effect where a boundary between two structures of interest falls in the midst of a voxel giving a signal value that is a mixture of the two. We propose a method to restore the ideal boundary by splitting a voxel into subvoxels and reapportioning the signal into the subvoxels. Each voxel is divided by nearest neighbor interpolation. The gray level of each subvoxel is considered as “material” able to move between subvoxels but not between voxels. A partial differential equation is written to allow the material to flow towards the highest gradient direction, creating a “reverse” diffusion process. Flow is subject to constraints that tend to create step edges. Material is conserved in the process thereby conserving signal. The method proceeds until the flow decreases to a low value. To test the method, synthetic images were downsampled to simulate the partial volume artifact and restored. Corrected images were remarkably closer both visually and quantitatively to the original images than those obtained from common interpolation methods: on simulated data standard deviation of the errors were 3.8%, 6.6%, and 7.1% of the dynamic range for the proposed method, bicubic, and bilinear interpolation, respectively. The method was relatively insensitive to noise. On gray level, scanned text, MRI physical phantom, and brain images, restored images processed with the new method were visually much closer to high-resolution counterparts than those obtained with common interpolation methods.
format Text
id pubmed-2324046
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-23240462008-04-22 Partial Volume Reduction by Interpolation with Reverse Diffusion Salvado, Olivier Hillenbrand, Claudia M. Wilson, David L. Int J Biomed Imaging Article Many medical images suffer from the partial volume effect where a boundary between two structures of interest falls in the midst of a voxel giving a signal value that is a mixture of the two. We propose a method to restore the ideal boundary by splitting a voxel into subvoxels and reapportioning the signal into the subvoxels. Each voxel is divided by nearest neighbor interpolation. The gray level of each subvoxel is considered as “material” able to move between subvoxels but not between voxels. A partial differential equation is written to allow the material to flow towards the highest gradient direction, creating a “reverse” diffusion process. Flow is subject to constraints that tend to create step edges. Material is conserved in the process thereby conserving signal. The method proceeds until the flow decreases to a low value. To test the method, synthetic images were downsampled to simulate the partial volume artifact and restored. Corrected images were remarkably closer both visually and quantitatively to the original images than those obtained from common interpolation methods: on simulated data standard deviation of the errors were 3.8%, 6.6%, and 7.1% of the dynamic range for the proposed method, bicubic, and bilinear interpolation, respectively. The method was relatively insensitive to noise. On gray level, scanned text, MRI physical phantom, and brain images, restored images processed with the new method were visually much closer to high-resolution counterparts than those obtained with common interpolation methods. Hindawi Publishing Corporation 2006 2006-02-14 /pmc/articles/PMC2324046/ /pubmed/23165058 http://dx.doi.org/10.1155/IJBI/2006/92092 Text en Copyright © IJBI O. Salvado et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Salvado, Olivier
Hillenbrand, Claudia M.
Wilson, David L.
Partial Volume Reduction by Interpolation with Reverse Diffusion
title Partial Volume Reduction by Interpolation with Reverse Diffusion
title_full Partial Volume Reduction by Interpolation with Reverse Diffusion
title_fullStr Partial Volume Reduction by Interpolation with Reverse Diffusion
title_full_unstemmed Partial Volume Reduction by Interpolation with Reverse Diffusion
title_short Partial Volume Reduction by Interpolation with Reverse Diffusion
title_sort partial volume reduction by interpolation with reverse diffusion
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2324046/
https://www.ncbi.nlm.nih.gov/pubmed/23165058
http://dx.doi.org/10.1155/IJBI/2006/92092
work_keys_str_mv AT salvadoolivier partialvolumereductionbyinterpolationwithreversediffusion
AT hillenbrandclaudiam partialvolumereductionbyinterpolationwithreversediffusion
AT wilsondavidl partialvolumereductionbyinterpolationwithreversediffusion