Cargando…

FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)

A cone beam circular half-scan scheme is becoming an attractive imaging method in cone beam CT since it improves the temporal resolution. Traditionally, the redundant data in the circular half-scan range is weighted by a central scanning plane-dependent weighting function; FDK algorithm is then appl...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Dong, Ning, Ruola
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2324061/
https://www.ncbi.nlm.nih.gov/pubmed/23165052
http://dx.doi.org/10.1155/IJBI/2006/83983
_version_ 1782152710955466752
author Yang, Dong
Ning, Ruola
author_facet Yang, Dong
Ning, Ruola
author_sort Yang, Dong
collection PubMed
description A cone beam circular half-scan scheme is becoming an attractive imaging method in cone beam CT since it improves the temporal resolution. Traditionally, the redundant data in the circular half-scan range is weighted by a central scanning plane-dependent weighting function; FDK algorithm is then applied on the weighted projection data for reconstruction. However, this scheme still suffers the attenuation coefficient drop inherited with FDK when the cone angle becomes large. A new heuristic cone beam geometry-dependent weighting scheme is proposed based on the idea that there exists less redundancy for the projection data away from the central scanning plane. The performance of FDKHSCW scheme is evaluated by comparing it to the FDK full-scan (FDKFS) scheme and the traditional FDK half-scan scheme with Parker's fan beam weighting function (FDKHSFW). Computer simulation is employed and conducted on a 3D Shepp-Logan phantom. The result illustrates a correction of FDKHSCW to the attenuation coefficient drop in the off-scanning plane associated with FDKFS and FDKHSFW while maintaining the same spatial resolution.
format Text
id pubmed-2324061
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-23240612008-04-22 FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW) Yang, Dong Ning, Ruola Int J Biomed Imaging Article A cone beam circular half-scan scheme is becoming an attractive imaging method in cone beam CT since it improves the temporal resolution. Traditionally, the redundant data in the circular half-scan range is weighted by a central scanning plane-dependent weighting function; FDK algorithm is then applied on the weighted projection data for reconstruction. However, this scheme still suffers the attenuation coefficient drop inherited with FDK when the cone angle becomes large. A new heuristic cone beam geometry-dependent weighting scheme is proposed based on the idea that there exists less redundancy for the projection data away from the central scanning plane. The performance of FDKHSCW scheme is evaluated by comparing it to the FDK full-scan (FDKFS) scheme and the traditional FDK half-scan scheme with Parker's fan beam weighting function (FDKHSFW). Computer simulation is employed and conducted on a 3D Shepp-Logan phantom. The result illustrates a correction of FDKHSCW to the attenuation coefficient drop in the off-scanning plane associated with FDKFS and FDKHSFW while maintaining the same spatial resolution. Hindawi Publishing Corporation 2006 2006-09-05 /pmc/articles/PMC2324061/ /pubmed/23165052 http://dx.doi.org/10.1155/IJBI/2006/83983 Text en Copyright © IJBI D. Yang and R. Ning https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Yang, Dong
Ning, Ruola
FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
title FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
title_full FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
title_fullStr FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
title_full_unstemmed FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
title_short FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
title_sort fdk half-scan with a heuristic weighting scheme on a flat panel detector-based cone beam ct (fdkhscw)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2324061/
https://www.ncbi.nlm.nih.gov/pubmed/23165052
http://dx.doi.org/10.1155/IJBI/2006/83983
work_keys_str_mv AT yangdong fdkhalfscanwithaheuristicweightingschemeonaflatpaneldetectorbasedconebeamctfdkhscw
AT ningruola fdkhalfscanwithaheuristicweightingschemeonaflatpaneldetectorbasedconebeamctfdkhscw