Cargando…

Management of Contaminated Autologous Grafts in Plastic Surgery

Background: Contamination of autologous grafts unfortunately occurs in plastic surgery, but the literature provides no guidance for management of such incidents. Methods: American Society of Aesthetic Plastic Surgery members were asked to complete an online survey that asked about the number and cau...

Descripción completa

Detalles Bibliográficos
Autores principales: Centeno, Robert F, Desai, Ankit R, Watson, Marla E
Formato: Texto
Lenguaje:English
Publicado: Open Science Company, LLC 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2344133/
https://www.ncbi.nlm.nih.gov/pubmed/18496583
_version_ 1782152826206552064
author Centeno, Robert F
Desai, Ankit R
Watson, Marla E
author_facet Centeno, Robert F
Desai, Ankit R
Watson, Marla E
author_sort Centeno, Robert F
collection PubMed
description Background: Contamination of autologous grafts unfortunately occurs in plastic surgery, but the literature provides no guidance for management of such incidents. Methods: American Society of Aesthetic Plastic Surgery members were asked to complete an online survey that asked about the number and causes of graft contaminations experienced, how surgeons dealt with the problem, the clinical outcomes, and patient disclosure. Results: Nineteen hundred surgeons were asked to participate in the survey, and 223 responded. Of these, 70% had experienced at least 1 graft contamination incident, with 26% experiencing 4 or more. The most frequently reported reason for graft contamination was a graft falling on the floor (reported by 75%). Nearly two thirds of the contaminated grafts related to craniofacial procedures. Ninety-four percent of grafts were managed with decontamination and completion of the operation. The most common method of decontamination was washing with povidone-iodine, but this practice is contrary to recommendations in the literature. Only 3 surgeons (1.9%) said a clinical infection developed following decontaminated graft use. Patients were not informed in 60% of graft contamination incidents. The survey results and review of the literature led to development of algorithms for the management of inadvertent graft contamination and patient disclosure. Conclusions: Although autologous grafts do become contaminated in plastic surgery, the overwhelming majority can be safely decontaminated and produce minimal or no clinical sequelae. The algorithms presented are intended to serve as guides for prevention of contamination events or for their management should they occur.
format Text
id pubmed-2344133
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Open Science Company, LLC
record_format MEDLINE/PubMed
spelling pubmed-23441332008-05-22 Management of Contaminated Autologous Grafts in Plastic Surgery Centeno, Robert F Desai, Ankit R Watson, Marla E Eplasty Article Background: Contamination of autologous grafts unfortunately occurs in plastic surgery, but the literature provides no guidance for management of such incidents. Methods: American Society of Aesthetic Plastic Surgery members were asked to complete an online survey that asked about the number and causes of graft contaminations experienced, how surgeons dealt with the problem, the clinical outcomes, and patient disclosure. Results: Nineteen hundred surgeons were asked to participate in the survey, and 223 responded. Of these, 70% had experienced at least 1 graft contamination incident, with 26% experiencing 4 or more. The most frequently reported reason for graft contamination was a graft falling on the floor (reported by 75%). Nearly two thirds of the contaminated grafts related to craniofacial procedures. Ninety-four percent of grafts were managed with decontamination and completion of the operation. The most common method of decontamination was washing with povidone-iodine, but this practice is contrary to recommendations in the literature. Only 3 surgeons (1.9%) said a clinical infection developed following decontaminated graft use. Patients were not informed in 60% of graft contamination incidents. The survey results and review of the literature led to development of algorithms for the management of inadvertent graft contamination and patient disclosure. Conclusions: Although autologous grafts do become contaminated in plastic surgery, the overwhelming majority can be safely decontaminated and produce minimal or no clinical sequelae. The algorithms presented are intended to serve as guides for prevention of contamination events or for their management should they occur. Open Science Company, LLC 2008-04-22 /pmc/articles/PMC2344133/ /pubmed/18496583 Text en Copyright © 2008 The Author(s) http://creativecommons.org/licenses/by/2.0/ This is an open-access article whereby the authors retain copyright of the work. The article is distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Centeno, Robert F
Desai, Ankit R
Watson, Marla E
Management of Contaminated Autologous Grafts in Plastic Surgery
title Management of Contaminated Autologous Grafts in Plastic Surgery
title_full Management of Contaminated Autologous Grafts in Plastic Surgery
title_fullStr Management of Contaminated Autologous Grafts in Plastic Surgery
title_full_unstemmed Management of Contaminated Autologous Grafts in Plastic Surgery
title_short Management of Contaminated Autologous Grafts in Plastic Surgery
title_sort management of contaminated autologous grafts in plastic surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2344133/
https://www.ncbi.nlm.nih.gov/pubmed/18496583
work_keys_str_mv AT centenorobertf managementofcontaminatedautologousgraftsinplasticsurgery
AT desaiankitr managementofcontaminatedautologousgraftsinplasticsurgery
AT watsonmarlae managementofcontaminatedautologousgraftsinplasticsurgery