Cargando…

The virtual haptic back: A simulation for training in palpatory diagnosis

BACKGROUND: Models and simulations are finding increased roles in medical education. The Virtual Haptic Back (VHB) is a virtual reality simulation of the mechanical properties of the human back designed as an aid to teaching clinical palpatory diagnosis. METHODS: Eighty-nine first year medical stude...

Descripción completa

Detalles Bibliográficos
Autores principales: Howell, John N, Conatser, Robert R, Williams, Robert L, Burns, Janet M, Eland, David C
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362113/
https://www.ncbi.nlm.nih.gov/pubmed/18387190
http://dx.doi.org/10.1186/1472-6920-8-14
_version_ 1782153380341219328
author Howell, John N
Conatser, Robert R
Williams, Robert L
Burns, Janet M
Eland, David C
author_facet Howell, John N
Conatser, Robert R
Williams, Robert L
Burns, Janet M
Eland, David C
author_sort Howell, John N
collection PubMed
description BACKGROUND: Models and simulations are finding increased roles in medical education. The Virtual Haptic Back (VHB) is a virtual reality simulation of the mechanical properties of the human back designed as an aid to teaching clinical palpatory diagnosis. METHODS: Eighty-nine first year medical students of the Ohio University College of Osteopathic Medicine carried out six, 15-minute practice sessions with the VHB, plus tests before and after the sessions in order to monitor progress in identifying regions of simulated abnormal tissue compliance. Students palpated with two digits, fingers or thumbs, by placing them in gimbaled thimbles at the ends of PHANToM 3.0(® )haptic interface arms. The interface simulated the contours and compliance of the back surface by the action of electric motors. The motors limited the compression of the virtual tissues induced by the palpating fingers, by generating counterforces. Users could see the position of their fingers with respect to the back on a video monitor just behind the plane of the haptic back. The abnormal region varied randomly among 12 locations between trials. During the practice sessions student users received immediate feedback following each trial, indicating either a correct choice or the actual location of the abnormality if an incorrect choice had been made. This allowed the user to feel the actual abnormality before going on to the next trial. Changes in accuracy, speed and Weber fraction across practice sessions were analyzed using a repeated measures analysis of variance. RESULTS: Students improved in accuracy and speed of diagnosis with practice. The smallest difference in simulated tissue compliance users were able to detect improved from 28% (SD = 9.5%) to 14% (SD = 4.4%) during the practice sessions while average detection time decreased from 39 (SD = 19.8) to 17 (SD = 11.7) seconds. When asked in anonymous evaluation questionnaires if they judged the VHB practice to be helpful to them in the clinical palpation and manual medicine laboratory, 41% said yes, 51% said maybe, and 8% said no. CONCLUSION: The VHB has potential value as a teaching aid for students in the initial phases of learning palpatory diagnosis.
format Text
id pubmed-2362113
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-23621132008-04-30 The virtual haptic back: A simulation for training in palpatory diagnosis Howell, John N Conatser, Robert R Williams, Robert L Burns, Janet M Eland, David C BMC Med Educ Research Article BACKGROUND: Models and simulations are finding increased roles in medical education. The Virtual Haptic Back (VHB) is a virtual reality simulation of the mechanical properties of the human back designed as an aid to teaching clinical palpatory diagnosis. METHODS: Eighty-nine first year medical students of the Ohio University College of Osteopathic Medicine carried out six, 15-minute practice sessions with the VHB, plus tests before and after the sessions in order to monitor progress in identifying regions of simulated abnormal tissue compliance. Students palpated with two digits, fingers or thumbs, by placing them in gimbaled thimbles at the ends of PHANToM 3.0(® )haptic interface arms. The interface simulated the contours and compliance of the back surface by the action of electric motors. The motors limited the compression of the virtual tissues induced by the palpating fingers, by generating counterforces. Users could see the position of their fingers with respect to the back on a video monitor just behind the plane of the haptic back. The abnormal region varied randomly among 12 locations between trials. During the practice sessions student users received immediate feedback following each trial, indicating either a correct choice or the actual location of the abnormality if an incorrect choice had been made. This allowed the user to feel the actual abnormality before going on to the next trial. Changes in accuracy, speed and Weber fraction across practice sessions were analyzed using a repeated measures analysis of variance. RESULTS: Students improved in accuracy and speed of diagnosis with practice. The smallest difference in simulated tissue compliance users were able to detect improved from 28% (SD = 9.5%) to 14% (SD = 4.4%) during the practice sessions while average detection time decreased from 39 (SD = 19.8) to 17 (SD = 11.7) seconds. When asked in anonymous evaluation questionnaires if they judged the VHB practice to be helpful to them in the clinical palpation and manual medicine laboratory, 41% said yes, 51% said maybe, and 8% said no. CONCLUSION: The VHB has potential value as a teaching aid for students in the initial phases of learning palpatory diagnosis. BioMed Central 2008-04-03 /pmc/articles/PMC2362113/ /pubmed/18387190 http://dx.doi.org/10.1186/1472-6920-8-14 Text en Copyright © 2008 Howell et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Howell, John N
Conatser, Robert R
Williams, Robert L
Burns, Janet M
Eland, David C
The virtual haptic back: A simulation for training in palpatory diagnosis
title The virtual haptic back: A simulation for training in palpatory diagnosis
title_full The virtual haptic back: A simulation for training in palpatory diagnosis
title_fullStr The virtual haptic back: A simulation for training in palpatory diagnosis
title_full_unstemmed The virtual haptic back: A simulation for training in palpatory diagnosis
title_short The virtual haptic back: A simulation for training in palpatory diagnosis
title_sort virtual haptic back: a simulation for training in palpatory diagnosis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362113/
https://www.ncbi.nlm.nih.gov/pubmed/18387190
http://dx.doi.org/10.1186/1472-6920-8-14
work_keys_str_mv AT howelljohnn thevirtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT conatserrobertr thevirtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT williamsrobertl thevirtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT burnsjanetm thevirtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT elanddavidc thevirtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT howelljohnn virtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT conatserrobertr virtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT williamsrobertl virtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT burnsjanetm virtualhapticbackasimulationfortraininginpalpatorydiagnosis
AT elanddavidc virtualhapticbackasimulationfortraininginpalpatorydiagnosis