Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
1999
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362284/ https://www.ncbi.nlm.nih.gov/pubmed/10360670 http://dx.doi.org/10.1038/sj.bjc.6690436 |
_version_ | 1782153419583127552 |
---|---|
author | de Vries, T J Fourkour, A Punt, C J A van de Locht, L T F Wobbes, T Bosch, S van den Rooij, M J M de Mensink, E J B M Ruiter, D J Muijen, G N P van |
author_facet | de Vries, T J Fourkour, A Punt, C J A van de Locht, L T F Wobbes, T Bosch, S van den Rooij, M J M de Mensink, E J B M Ruiter, D J Muijen, G N P van |
author_sort | de Vries, T J |
collection | PubMed |
description | In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of detection of tyrosinase and MART-1 transcripts in 106 blood samples from 68 melanoma patients (mainly stages III and IV). With this study, we aimed to improve insight in the reproducibility of a RT-PCR for the detection of (minimal) amounts of circulating melanoma cells. We performed two reverse transcriptions on each mRNA sample and performed tyrosinase and MART-1 nested PCRs in duplicate per cDNA sample. Thus, four tyrosinase and four MART-1 measurements were performed per blood sample. In our study, the majority of blood samples was negative for tyrosinase (80%) or MART-1 (66%). Only four samples were positive in all four determinations for tyrosinase and seven for MART-1. Variable results (1–3 times positive results) were obtained for tyrosinase and MART-1 in 16% and 27% respectively. MART-1 PCR had a better performance than tyrosinase PCR. Sensitivity increased when both markers were used. We reasoned that the low number of melanoma marker PCR-positive blood samples can be explained by differences in mRNA quality. By using real-time quantitative PCR, we found that this was not the case: amplification of porphobilinogen deaminase (PBGD), a low copy household gene, was not different in blood samples in which a melanoma marker was not detected from groups in which this marker was detected more or less consistently (1–4 times). When applying real-time quantitative PCR for tyrosinase and MART-1, we found that a low amount of SK-MEL-28 cell equivalents was present in the blood of melanoma patients, with a higher number of equivalents in the group with a consistently positive result. We conclude that low reproducibility of a repeated assay for the detection of circulating melanoma cells is not caused by differences in mRNA quality between the samples, but due to low numbers of amplifiable target mRNA molecules in the mRNA sample. Use of more than one marker and repetition of the assay will increase the probability of finding positive PCR results. © 1999 Cancer Research Campaign |
format | Text |
id | pubmed-2362284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1999 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-23622842009-09-10 Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR de Vries, T J Fourkour, A Punt, C J A van de Locht, L T F Wobbes, T Bosch, S van den Rooij, M J M de Mensink, E J B M Ruiter, D J Muijen, G N P van Br J Cancer Regular Article In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of detection of tyrosinase and MART-1 transcripts in 106 blood samples from 68 melanoma patients (mainly stages III and IV). With this study, we aimed to improve insight in the reproducibility of a RT-PCR for the detection of (minimal) amounts of circulating melanoma cells. We performed two reverse transcriptions on each mRNA sample and performed tyrosinase and MART-1 nested PCRs in duplicate per cDNA sample. Thus, four tyrosinase and four MART-1 measurements were performed per blood sample. In our study, the majority of blood samples was negative for tyrosinase (80%) or MART-1 (66%). Only four samples were positive in all four determinations for tyrosinase and seven for MART-1. Variable results (1–3 times positive results) were obtained for tyrosinase and MART-1 in 16% and 27% respectively. MART-1 PCR had a better performance than tyrosinase PCR. Sensitivity increased when both markers were used. We reasoned that the low number of melanoma marker PCR-positive blood samples can be explained by differences in mRNA quality. By using real-time quantitative PCR, we found that this was not the case: amplification of porphobilinogen deaminase (PBGD), a low copy household gene, was not different in blood samples in which a melanoma marker was not detected from groups in which this marker was detected more or less consistently (1–4 times). When applying real-time quantitative PCR for tyrosinase and MART-1, we found that a low amount of SK-MEL-28 cell equivalents was present in the blood of melanoma patients, with a higher number of equivalents in the group with a consistently positive result. We conclude that low reproducibility of a repeated assay for the detection of circulating melanoma cells is not caused by differences in mRNA quality between the samples, but due to low numbers of amplifiable target mRNA molecules in the mRNA sample. Use of more than one marker and repetition of the assay will increase the probability of finding positive PCR results. © 1999 Cancer Research Campaign Nature Publishing Group 1999-05 /pmc/articles/PMC2362284/ /pubmed/10360670 http://dx.doi.org/10.1038/sj.bjc.6690436 Text en Copyright © 1999 Cancer Research Campaign https://creativecommons.org/licenses/by/4.0/This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material.If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit https://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Regular Article de Vries, T J Fourkour, A Punt, C J A van de Locht, L T F Wobbes, T Bosch, S van den Rooij, M J M de Mensink, E J B M Ruiter, D J Muijen, G N P van Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR |
title | Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR |
title_full | Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR |
title_fullStr | Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR |
title_full_unstemmed | Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR |
title_short | Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR |
title_sort | reproducibility of detection of tyrosinase and mart-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative rt-pcr |
topic | Regular Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362284/ https://www.ncbi.nlm.nih.gov/pubmed/10360670 http://dx.doi.org/10.1038/sj.bjc.6690436 |
work_keys_str_mv | AT devriestj reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT fourkoura reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT puntcja reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT vandelochtltf reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT wobbest reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT boschsvanden reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT rooijmjmde reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT mensinkejbm reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT ruiterdj reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr AT muijengnpvan reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr |