Cargando…

Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR

In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of...

Descripción completa

Detalles Bibliográficos
Autores principales: de Vries, T J, Fourkour, A, Punt, C J A, van de Locht, L T F, Wobbes, T, Bosch, S van den, Rooij, M J M de, Mensink, E J B M, Ruiter, D J, Muijen, G N P van
Formato: Texto
Lenguaje:English
Publicado: Nature Publishing Group 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362284/
https://www.ncbi.nlm.nih.gov/pubmed/10360670
http://dx.doi.org/10.1038/sj.bjc.6690436
_version_ 1782153419583127552
author de Vries, T J
Fourkour, A
Punt, C J A
van de Locht, L T F
Wobbes, T
Bosch, S van den
Rooij, M J M de
Mensink, E J B M
Ruiter, D J
Muijen, G N P van
author_facet de Vries, T J
Fourkour, A
Punt, C J A
van de Locht, L T F
Wobbes, T
Bosch, S van den
Rooij, M J M de
Mensink, E J B M
Ruiter, D J
Muijen, G N P van
author_sort de Vries, T J
collection PubMed
description In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of detection of tyrosinase and MART-1 transcripts in 106 blood samples from 68 melanoma patients (mainly stages III and IV). With this study, we aimed to improve insight in the reproducibility of a RT-PCR for the detection of (minimal) amounts of circulating melanoma cells. We performed two reverse transcriptions on each mRNA sample and performed tyrosinase and MART-1 nested PCRs in duplicate per cDNA sample. Thus, four tyrosinase and four MART-1 measurements were performed per blood sample. In our study, the majority of blood samples was negative for tyrosinase (80%) or MART-1 (66%). Only four samples were positive in all four determinations for tyrosinase and seven for MART-1. Variable results (1–3 times positive results) were obtained for tyrosinase and MART-1 in 16% and 27% respectively. MART-1 PCR had a better performance than tyrosinase PCR. Sensitivity increased when both markers were used. We reasoned that the low number of melanoma marker PCR-positive blood samples can be explained by differences in mRNA quality. By using real-time quantitative PCR, we found that this was not the case: amplification of porphobilinogen deaminase (PBGD), a low copy household gene, was not different in blood samples in which a melanoma marker was not detected from groups in which this marker was detected more or less consistently (1–4 times). When applying real-time quantitative PCR for tyrosinase and MART-1, we found that a low amount of SK-MEL-28 cell equivalents was present in the blood of melanoma patients, with a higher number of equivalents in the group with a consistently positive result. We conclude that low reproducibility of a repeated assay for the detection of circulating melanoma cells is not caused by differences in mRNA quality between the samples, but due to low numbers of amplifiable target mRNA molecules in the mRNA sample. Use of more than one marker and repetition of the assay will increase the probability of finding positive PCR results. © 1999 Cancer Research Campaign
format Text
id pubmed-2362284
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-23622842009-09-10 Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR de Vries, T J Fourkour, A Punt, C J A van de Locht, L T F Wobbes, T Bosch, S van den Rooij, M J M de Mensink, E J B M Ruiter, D J Muijen, G N P van Br J Cancer Regular Article In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of detection of tyrosinase and MART-1 transcripts in 106 blood samples from 68 melanoma patients (mainly stages III and IV). With this study, we aimed to improve insight in the reproducibility of a RT-PCR for the detection of (minimal) amounts of circulating melanoma cells. We performed two reverse transcriptions on each mRNA sample and performed tyrosinase and MART-1 nested PCRs in duplicate per cDNA sample. Thus, four tyrosinase and four MART-1 measurements were performed per blood sample. In our study, the majority of blood samples was negative for tyrosinase (80%) or MART-1 (66%). Only four samples were positive in all four determinations for tyrosinase and seven for MART-1. Variable results (1–3 times positive results) were obtained for tyrosinase and MART-1 in 16% and 27% respectively. MART-1 PCR had a better performance than tyrosinase PCR. Sensitivity increased when both markers were used. We reasoned that the low number of melanoma marker PCR-positive blood samples can be explained by differences in mRNA quality. By using real-time quantitative PCR, we found that this was not the case: amplification of porphobilinogen deaminase (PBGD), a low copy household gene, was not different in blood samples in which a melanoma marker was not detected from groups in which this marker was detected more or less consistently (1–4 times). When applying real-time quantitative PCR for tyrosinase and MART-1, we found that a low amount of SK-MEL-28 cell equivalents was present in the blood of melanoma patients, with a higher number of equivalents in the group with a consistently positive result. We conclude that low reproducibility of a repeated assay for the detection of circulating melanoma cells is not caused by differences in mRNA quality between the samples, but due to low numbers of amplifiable target mRNA molecules in the mRNA sample. Use of more than one marker and repetition of the assay will increase the probability of finding positive PCR results. © 1999 Cancer Research Campaign Nature Publishing Group 1999-05 /pmc/articles/PMC2362284/ /pubmed/10360670 http://dx.doi.org/10.1038/sj.bjc.6690436 Text en Copyright © 1999 Cancer Research Campaign https://creativecommons.org/licenses/by/4.0/This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material.If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit https://creativecommons.org/licenses/by/4.0/.
spellingShingle Regular Article
de Vries, T J
Fourkour, A
Punt, C J A
van de Locht, L T F
Wobbes, T
Bosch, S van den
Rooij, M J M de
Mensink, E J B M
Ruiter, D J
Muijen, G N P van
Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
title Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
title_full Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
title_fullStr Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
title_full_unstemmed Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
title_short Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
title_sort reproducibility of detection of tyrosinase and mart-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative rt-pcr
topic Regular Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362284/
https://www.ncbi.nlm.nih.gov/pubmed/10360670
http://dx.doi.org/10.1038/sj.bjc.6690436
work_keys_str_mv AT devriestj reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT fourkoura reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT puntcja reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT vandelochtltf reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT wobbest reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT boschsvanden reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT rooijmjmde reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT mensinkejbm reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT ruiterdj reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr
AT muijengnpvan reproducibilityofdetectionoftyrosinaseandmart1transcriptsintheperipheralbloodofmelanomapatientsaqualitycontrolstudyusingrealtimequantitativertpcr