Cargando…

Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope

Peroral cholangioscopy (PCS) has been performed in 22 cases using XCHF-B200 (Olympus Optical Co.) since June 1995 and in 77 cases using CHF-B20 (Olympus Optical Co.) after EST from Jan. 1989. XCHF-B200 has a longer rigid portion of distal end and a smaller channel diameter than CHF-B20. The successf...

Descripción completa

Detalles Bibliográficos
Autores principales: Igarashi, Yoshinori, Ukita, Takeo, Inoue, Hirokazu, Ishiguro, Jun, Ogawa, Satoshi, Satou, Masahiro, Maetani, Iruru, Sakai, Yoshihiro
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362641/
https://www.ncbi.nlm.nih.gov/pubmed/18493506
http://dx.doi.org/10.1155/DTE.5.231
_version_ 1782153503463964672
author Igarashi, Yoshinori
Ukita, Takeo
Inoue, Hirokazu
Ishiguro, Jun
Ogawa, Satoshi
Satou, Masahiro
Maetani, Iruru
Sakai, Yoshihiro
author_facet Igarashi, Yoshinori
Ukita, Takeo
Inoue, Hirokazu
Ishiguro, Jun
Ogawa, Satoshi
Satou, Masahiro
Maetani, Iruru
Sakai, Yoshihiro
author_sort Igarashi, Yoshinori
collection PubMed
description Peroral cholangioscopy (PCS) has been performed in 22 cases using XCHF-B200 (Olympus Optical Co.) since June 1995 and in 77 cases using CHF-B20 (Olympus Optical Co.) after EST from Jan. 1989. XCHF-B200 has a longer rigid portion of distal end and a smaller channel diameter than CHF-B20. The successful rate of PCS using XCHF-B200 (82%) was lower than that of CHF-B20 (89%). The vascular pattern and fine vertical groove of the bile duct mucosa were shown more clearly on the photographs obtained with XCHF-B200 than those obtained with CHF-B20. However, not enough biopsy specimens could be obtained because the channel diameter of XCHF-B200 was rather small. If the length of rigid portion and biopsy channel of XCHF-B200 are improved, PCS using XCHF-B200 will be more useful for the diagnosis of bile duct disorders.
format Text
id pubmed-2362641
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-23626412008-05-20 Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope Igarashi, Yoshinori Ukita, Takeo Inoue, Hirokazu Ishiguro, Jun Ogawa, Satoshi Satou, Masahiro Maetani, Iruru Sakai, Yoshihiro Diagn Ther Endosc Research Article Peroral cholangioscopy (PCS) has been performed in 22 cases using XCHF-B200 (Olympus Optical Co.) since June 1995 and in 77 cases using CHF-B20 (Olympus Optical Co.) after EST from Jan. 1989. XCHF-B200 has a longer rigid portion of distal end and a smaller channel diameter than CHF-B20. The successful rate of PCS using XCHF-B200 (82%) was lower than that of CHF-B20 (89%). The vascular pattern and fine vertical groove of the bile duct mucosa were shown more clearly on the photographs obtained with XCHF-B200 than those obtained with CHF-B20. However, not enough biopsy specimens could be obtained because the channel diameter of XCHF-B200 was rather small. If the length of rigid portion and biopsy channel of XCHF-B200 are improved, PCS using XCHF-B200 will be more useful for the diagnosis of bile duct disorders. Hindawi Publishing Corporation 1999 /pmc/articles/PMC2362641/ /pubmed/18493506 http://dx.doi.org/10.1155/DTE.5.231 Text en Copyright © 1999 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Igarashi, Yoshinori
Ukita, Takeo
Inoue, Hirokazu
Ishiguro, Jun
Ogawa, Satoshi
Satou, Masahiro
Maetani, Iruru
Sakai, Yoshihiro
Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope
title Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope
title_full Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope
title_fullStr Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope
title_full_unstemmed Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope
title_short Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope
title_sort clinical evaluation of the peroral cholangioscopy using a new videoscope
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2362641/
https://www.ncbi.nlm.nih.gov/pubmed/18493506
http://dx.doi.org/10.1155/DTE.5.231
work_keys_str_mv AT igarashiyoshinori clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope
AT ukitatakeo clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope
AT inouehirokazu clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope
AT ishigurojun clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope
AT ogawasatoshi clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope
AT satoumasahiro clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope
AT maetaniiruru clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope
AT sakaiyoshihiro clinicalevaluationoftheperoralcholangioscopyusinganewvideoscope